HMT360 Series Intrinsically Safe Humidity and Temperature TransmittersFor operation in up to Zone 0 / 20 Features • Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity and wet bulb temperature • Intrinsically safe • Vaisala HUMICAP® Sensor features high accuracy, excellent long-term stability, and negligible hysteresis • Six probe options • Traceable calibration (certificate included) Vaisala HUMICAP® Humidity and Temperature Transmitter Series HMT360 are the ideal solution for measuring humidity in hazardous areas. They operate safely and reliably even in the most hazardous classifications, such as zone 0. The HMT360 transmitters' proven performance and technology conform with rigorous international standards. • Safe operation with the entire transmitter in hazardous areas: Division 1 and 2 (USA, Canada), Categories 1G / Zone 0 and 1D / Zone 20 with protection cover (EU) • Designed for harsh conditions • Temperature range between -70 ... +180 °C (-94 ... +356 °F) depending on the probe option Intrinsically Safe The entire HMT360 transmitter can be installed directly in explosive areas. It can withstand continuous exposure to potentially explosive environments that contain flammable gases or dust. Customized Configuration Due to the options and accessories, the HMT360 series is truly flexible. Customers may specify the transmitter configuration when ordering the instrument. However, changes in configuration can also easily be made in the field. Interchangeable Probes HMT360 offers six probe options for various applications: • HMT361 - wall mount • HMT363 - confined spaces • HMT364 - pressurized spaces • HMT365 - high temperature • HMT367 - high humidity • HMT368 - pressurized pipelines The interchangeable probes enable fast and easy removal or re-installation when required. Calibration, for example, is easy to perform due to the modular structure. All calibration coefficients are included in the probe unit itself, which means that probes can be switched between transmitter bodies without losing the accuracy. Optimized Sensors In addition to the standard Vaisala HUMICAP® Sensor, an application-specific, very chemically durable sensor is also available. Long-term Solution The HMT360 transmitters are an investment: their rugged design, combined with trouble-free operation, ensure a long-term solution for monitoring humidity and dew point in explosive environments. Customized calibration and maintenance contracts for the HMT360 series are available on re

Open the catalog to page 1
HMT360 Series Intrinsically SafeHumidity and TemperatureTransmitters - 2

Interchangeable Probes for HMT360 Intrinsically Safe Humidity and Temperature Transmitter -40 … +60 °C (-40 … +140 °F) 12 mm (0.47 in) Temperature range Probe diameter HMT363 for Confined Spaces Temperature range with teflon cable Temperature range with rubber cable Probe cable length Probe diameter The HMT361 probe in this picture has a stainless steel netting filter. Installation Duct installation kit Cable gland M20x1.5 with splitting seal Swagelok for 12mm probe, 1/2" NPT thread adjustable flange duct wall Left: Installation kit for duct mounting. Right: Installation flange. Aluminum or...

Open the catalog to page 2
HMT360 Series Intrinsically SafeHumidity and TemperatureTransmitters - 3

HMT364 for High Pressure Temperature range -70 ... +180 °C (-94 ... +356 °F) Probe cable length 2, 5 or 10 meters (6 ft 7 in, 16 ft 5 in, The HMT364 probe is designed for measurement in pressurized spaces or vacuum chambers. HMT365 for High Temperature Temperature range -70 ... +180 °C (-94 ... +356 °F) Probe cable length 2, 5 or 10 meters (6 ft 7 in, 16 ft 5 in, Installation Mounting flange 210696 Cable gland M20x1.5 with splitting seal HMP247CG drilling 16...22 (0.63...0.87) HMT365 probe and stainless steel installation flange. Dimensions in mm (inches). The HMT365 probe is designed for...

Open the catalog to page 3
HMT360 Series Intrinsically SafeHumidity and TemperatureTransmitters - 4

The HMT367 probe is constructed to be installed in environments with high humidities. HMT368 for Pressurized Pipelines Temperature range -70 ... +180 °C (-94 ... +356 °F) Probe cable length 2, 5 or 10 meters (6 ft 7 in, 16 ft 5 in, Available probe lengths 226 mm/448 mm (8.90 in/17.6 in) Installation Fitting body ISO1/2 solid structure DRW212076SP Fitting body NPT1/2 solid structure NPTFITBODASP Ball valve ISO 1/2 with welding joint BALLVALVE-1 Length for standard / optional probes *freely user adjustable length

Open the catalog to page 4
HMT360 Series Intrinsically SafeHumidity and TemperatureTransmitters - 5

Measurement Performance Relative Humidity Measurement range 0 ... 100 %RH Accuracy (Including Non-linearity, Hysteresis, and Repeatability): With Vaisala HUMICAP® 180R For typical applications Factory calibration uncertainty ± 0.6 %RH (0 ... 40 %RH) (Defined as ±2 standard deviation limits. Small variations possible, see also calibration certificate.) Response Time (90 %) at +20 °C (+68 °F) in Still Air: With grid filter 17 s With grid + steel netting filter 50 s With sintered filter 60 s Temperature Measurement range -70 ... +180 °C (-94 ... +356 °F) (depends on selected probe) Typical...

Open the catalog to page 5
HMT360 Series Intrinsically SafeHumidity and TemperatureTransmitters - 6

Classification with Current Outputs Europe / VTT VAISALA www.vaisala.com Published by Vaisala | B210956EN-H © Vaisala 2018 All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. Any reproduction, transfer, distribution or storage of information contained in this document is strictly prohibited. All specifications — technical included — are subject to change without notice.