video corpo

SMGM
20Pages

{{requestButtons}}

Catalog excerpts

SMGM - 1

SMGM | SMGX COMMUNICATION SYS TEMS

Open the catalog to page 1
SMGM - 2

SMGM | SMGX – KEY HIGHLIGHTS WIDE RANGE OF APPLICATIONS With the vCOM product family for mobile data transmission, VAHLE serves indoor installations with the SMGM as well as outdoor installations with the SMGX. This product variety offers a selection for different segment lengths and mechanical tolerances. HF-SECURE The SMG profile’s interference-free design prevents signals from transmitting beyond the aluminum housing, allowing it to work alongside other industrial free radio systems. A radio license is not required. All HF components are factory tested and measured before each delivery,...

Open the catalog to page 2
SMGM - 3

SMGM | SMGX – OPERATION Modern production requires expansive volumes of data transmission for diagnosis and management. While this data is often transmitted for simple transport tasks in mobile applications via concutor linces with low transmission rates, this method of communication cannot stand up to the requirements of more complex applications that demand higher data rates. The data communication system SMGM (Slotted Microwave Guide Mini) was especially developed for these applications and enables the integration of fail-safe data transmission into proven VAHLE conductor systems. The...

Open the catalog to page 3
SMGM - 4

SMGM – SYSTEM OVERVIEW 3 1 DIAGNOSIS SEGMENT SMGM Stationary Segment Interface SMGM Mobile Segment Interface SMGM Profile SMGM SI-2 Dual Feed SMGM Mobile Coupler SMGM System Controller

Open the catalog to page 4
SMGM - 6

SMGM – DIAGNOSIS / SERVICE COMPONENT AND SYSTEM QUALITY SURVEILLANCE All SMGM components are under surveillance via the system controller regarding their availability. If one of the components becomes inoperative, a respective prompt will be sent to the superordinate management component/controller. For safe operation, compliance with different communication parameters (e.g. levels) is necessary. The stationary interface permanently monitors the compliance of these system-relevant parameters. If one of these parameters is not met, the system controllers receives an error message via...

Open the catalog to page 6
SMGM - 7

SMGM – SWITCH CONCEPT / SMGM-TC SWITCH CONCEPT For interruption-free communication, a stationary source interface’s HF signal is split at feed switches to both turnout segments via SMGM SI-2 module. SMGX – SYSTEM OVERVIEW 1 SMGM Stationary Segment Interface SMGM Mobile Segment Interface SMGX Profile SMGX Mobile Coupler PROFINET SWITCH Inscribing Inscribing with dimensions

Open the catalog to page 7
SMGM - 8

SMGM | SMGX – STATIONARY AND MOBILE INTERFACES TECHNICAL DATA Mechanical data INFORMATION FOR USING INTERFACES Only components of the same system can be used with each other. I.e. if the interface on the stationary side has „standard configuration,“ the interface on the mobile side must also have „standard configuration.“ The SMGM-RU is a universal spare unit. It is the only interface that can adopt the configuration of any ot

Open the catalog to page 8
SMGM - 9

SMGM | SMGX – STATIONARY AND MOBILE INTERFACES SYSTEM TYPES LITE version The LITE version is applied in applications with one segment and up to four mobile users. Standard version The Standard version is applied in applications with min. one segment Advanced version The Advanced version is applied in applications with one segment and up to three mobile users. Standard / Advanced-Interface Communication cycle Process data transmission Video data transmission Stationary Interfaces Mobile Interfaces Description Transfer rate (gross) Process data transmission Video data transmission (1) The...

Open the catalog to page 9
SMGM - 10

SMGM | SMGX – STATIONARY INTERFACES RANGE OF PRODUCTS Description Segment Interface for one segment and max. four users Segment Interface for one segment and max. 15 users Segment Interface for two segments and max. 15 users Segment Interface for one segment with ADV Configuration System Controller Replacement Unit SMGM | SMGX – MOBILE INTERFACES SMGM module RANGE OF PRODUCTS Description Device Interface LITE for one mobile coupler Device Interface LITE for two mobile couplers Device Interface Standard for two mobile couplers Device Interface Advanced for one mobile coupler Device Interface...

Open the catalog to page 10
SMGM - 11

SMGM | SMGX CABLES Cable Ecoflex RANGE OF PRODUCTS: <5 M LENGTH Description Connection cables Plug 0° to 0° Connection cables Plug 90° to 0

Open the catalog to page 11
SMGM - 12

SMGM | SMGX CABLE RANGE OF PRODUCTS: >5 M LENGTH Description Extension cables Plug N-socket to N-socket Extension cables Plug 90° to N-socket Extension cables Plug 0° to N-socket

Open the catalog to page 12
SMGM - 13

SMGM | SMGX – PROFILE RANGE OF PRODUCTS Description SMGM-Profile incl. accessories SMGX-Profile incl. accessories SMGM | SMGX – PROFILE SUPPORT It is a matter of a pseudo order number. Our Techsales will check the profile components in detail by ordering

Open the catalog to page 13
SMGM - 14

SMGM | SMGX – FUNNEL RANGE OF PRODUCTS Description SMGM | SMGX – MOBILE COUPLER SMGM-Coupler (short arm version) SMGM-Coupler (long arm version) RANGE OF PRODUCTS Description SMGM-GPMK+V (2-pole base plate for SMGM) SMGM system

Open the catalog to page 14
SMGM - 15

SMGM – SUCTION HEADS Suction head RANGE OF PRODUCTS Description Suction head for EMS applications Suction head for SKID applications SMGM – SYSTEM INTEGRATION EXAMPLE: EMS APPLICATION* 1 In this application, the SMGM profile is mounted between the APOS optic Datamatrix Code Strip and U10 profile as part of the EMS profile. 2 The SMGM mobile coupler is integrated between the APOS Optic reading head and the U10 current collector. 3 A special bracket provides a common mounting plate for the APOS Optic reading head, the U10 current collector and also for the SMGM mobile coupler. * More system...

Open the catalog to page 15
SMGM - 16

SMGX – HEATING An optional heating system for the SMGX slotted microwave guide extends the application range to adverse environments. The system can also be retrofitted in existing installations and can be combined with a heating system of a VAHLE conductor system. RANGE OF PRODUCTS Description U profile for heating wire – 6 m Mounting bracket Center feed Switch cabinet with control system Heating wire The SMGX system can also be used on STS cranes in port. VAHLE offers a hinging boom for this purpose, which ensures smooth operation in this application. RANGE OF PRODUCTS Description Hinging...

Open the catalog to page 16

All VAHLE catalogs and technical brochures

  1. APOS Optic

    12 Pages

  2. SMGX

    20 Pages

  3. CPS 20kHz

    24 Pages

  4. CPS 140kHz

    32 Pages

  5. Festoon system

    28 Pages