video corpo

Enclosed conductor system LSV | LSVG
32Pages

{{requestButtons}}

Catalog excerpts

Enclosed conductor system LSV | LSVG - 1

LSV | LSVG ENCLOSED CONDUCTOR SYSTEMS

Open the catalog to page 1
Enclosed conductor system LSV | LSVG - 2

Powerail versions (Photos) Technical Data Basic Description Powerail Cat.-Nos. and Weights Engineering Data and Configurations Standard Sections & Curves Joint Material Brackets Hangers End Caps End Feeds Line Feeds Transfer and switch Arrangements Transfer Funnels Transfer Guides, straight cut Type LSV with Plastic shielding “FP” Type LSVG Type LSVG with sealing strip “D” Technical Data Temperature Resistance: Powerail – 40 °C up to + 100 °C (120 °C)(1) Sealing strip “D” up to + 80 °C Plastic shielding “FP” up to + 55 °C Collector – 40 °C/+ 70 °C (120 °C)(1) Max. continuous current: 300 A...

Open the catalog to page 2
Enclosed conductor system LSV | LSVG - 3

POWERAIL LSV AND LSVG General Expansion Joint Sections The Vahle Aluminium enclosed powerails LSV and LSVG are compact and safe prefabricated Electrification Systems. These systems are ideal for indoor and outdoor use, for all types of installations requiring a moving or movable source of electrical power: cranes, monorails, hoists, electric power tools, machine tools, storage and retrieval systems and many other mobile machinery applications. LSV and LSVG are especially well suited for higher ambient temperatures. The principal advantages of these systems are maximum electrical and...

Open the catalog to page 3
Enclosed conductor system LSV | LSVG - 4

TYPES, ENGINEERING DATA AND CATALOG NUMBERS LSV Control line Control line LSVG LSVG LSVG LSVG LSVG LSVG LSVG LSVG LSVG LSVG LSVG LSVG LSVG LSVG LSVG LSVG LSVG LSVG LSVG LSVG LSVG 10/ 60 HS LSVG 10/ 60 SS LSVG 10/100 HS LSVG 10/140 HS LSVG 10/200 HS(1) LSVG 11/ 60 HS LSVG 11/100 HS LSVG 11/140 HS LSVG 11/200 HS(1) Control line Control line Control line No. of conductors x copper section mm2 (2) With bolted joints only other types can be delivered with bolted joints without surcharge (on request). The ground conductor = PE is always connected to the powerail housing and marked accordingly....

Open the catalog to page 4
Enclosed conductor system LSV | LSVG - 5

Nominal Leakage Path • Add last number (1, 2, 3, 4 m length suffix) in accordance to bars required.

Open the catalog to page 5
Enclosed conductor system LSV | LSVG - 6

CURVED SECTION plug-in joint housing 60 - 140 A short lip profile in front (2)bolted Custom built Extra finish of LSV; surcharge Order- No. Type anodized housing copper conductors with stainless steel cap Order- No. Order- No. min. horizontal radius: 750 mm Consult factory for vertical bends Support spacing 750 up to max. 2000 mm, depending on the radius max. L = 3200 mm, max. <) = 120° Supplements for LSV: Illustration see page 2 Neoprene sealing strip D 0,225 Fastener for sealing strip (pair) Coupling for sealing strip for length exceeding 50 m Mounting trolley for sealing strip 0,260...

Open the catalog to page 6
Enclosed conductor system LSV | LSVG - 7

JOINT MATERIAL(2) Plug-in joints 60-140 A Bolted joints 60-300 A ground cable(1) 1 set joint fish plate VBLS 4/5 VBLS/E 4/5 VBLS 6/7 VBLS/E 6/7 VBLSG 4/5 VBLSG/E 4/5 Order- No. Order- No. anodized Bolted joints 60-300 A ground cable(1) 2 pegs 1 set joint cover 1 set joint fish plate Yellow/green ground cable factory pre-assembled. No joints required for uninsulated top conductors 5, 7, 9 and 11. Equel for power line and control line. VLGS 6/7 for 6- and 7-pole VLGS/E 6/7 60-200 Amp. VLGS 8/9 for 8- and 9-pole VLGS/E 8/9 60-200 Amp. VLGS 10/11 for 10- and 11-pole VLGS/E 10/11 60-200 Amp....

Open the catalog to page 7
Enclosed conductor system LSV | LSVG - 8

BRACKETS These brackets are easily bolted to any type of standard View without View without EHKL small claw version Order- No. with small claw Attention: Make sure that hoist wheels have enough clearance. Use small claw if necessary! -rail of EHKL is identical to type S 1, Order- No. Select next larger size bracket when your -beam dimension B is more than 170 mm and up to 300 mm. max. width 84 mm resp. 88 mm for plug-in joints w/o joint plates. Dim. in parenthesis refer to bolted joints with joint plates (see illustration).

Open the catalog to page 8
Enclosed conductor system LSV | LSVG - 9

All steel parts made of stainless steel. All steel parts made of stainless steel. locating clamp clamp Steel parts galvanized, clamp made of stainless steel. (1) (2) Illustrations show hangers mounted to powerail. Flat washers only to be used in slotted holes. Steel parts galvanized, clamp made of stainless steel.

Open the catalog to page 9
Enclosed conductor system LSV | LSVG - 10

L = LH version, R = RH version (see page 6) Plastic cap with plug-in joints Type Cable glands (cable Ø see table page 28): 4 & 5-pole 1 x M 32 6 & 7-pole 1 x M 32 and 1 x M 255 Aluminium cap with bolted joints Type Power line HS with PE KEL 4/60 L 192 150 KEL 5/60 L 192 160 KEL 6/60 L 192 170 KEL 7/60 L 192 180 Control line SS without PE Power line HS with PE KEL 4/60 R 60 KEL 5/60 R 60 KEL 6/60 R 60 KEL 7/60 R 60 Control line SS without PE L = LH version (1), R = RH version (see page 6) Plastic cap with plug-in joints Type Cable glands (cable Ø see table page 28): all types 1 x M 32 and 1...

Open the catalog to page 10
Enclosed conductor system LSV | LSVG - 11

c/w 2 m feed-in cable and 1 m powerail cable size: Cable glands (cable-Ø see table page 28) 4 + 5-pole 1 x M 32 power line 60 A 4 + 5-pole 1 x M 50 power line 100 und 140 A 4 + 5-pole 1 x M 50 power line 200 A 4 + 5-pole 1 x M 63 power line 300 A 6 + 7-pole 1 x M 32 and 1 x M 25 power line 60 A 6 + 7-pole 1 x M 50 and 1 x M 25 power line 100 und 140 A 6 + 7-pole 1 x M 50 and 1 x M 25 power line 200 A 4 + 6-pole 1 x M 32 control line 60 A Type(2) Power line HS with PE cable size: LALG 6/60 LALG 8/60 LALG 10/60 Cable glands (cable-Ø see table page 28) 6-11-pole 1 x M 32 and 1 x M 25 power...

Open the catalog to page 11
Enclosed conductor system LSV | LSVG - 12

TRANSFER AND SWITCH ARRANGEMENTS Contact section(1) Contact area Line feed Transfer funnel Contact area Turntable frame Transfer guide oblique cut Transfer guide Line feed Transfer guide max. 20 mm gap Transfer guide oblique cut Switch frame Please submit drawings of transfer applications. Specify dimenions a, b, c, R and angle ( max. 50°) Transfer funnels must not be activated before collectors are fully engaged. Flexible support type tow arms (see page 22) for collectors are essential with contact sections.

Open the catalog to page 12
Enclosed conductor system LSV | LSVG - 13

TRANSFER FUNNEL(2) c/w 0.5 m powerail and joint material Towing arms KFM or KFML (see page 22) required. Lateral tolerance upto max. 15 mm, vertical tolerance upto max. 10 mm. Max. entry speed collector unit: 60 m/min. Connect the conductor to mains only if all carbons of the collector have full contact to the conductor rail. Arrangement see page 12. Illustration shows L. H. version short lip in front (see page 6) Power line HS with PE ETL 4/ 60 L 1,450 ETL 4/100 L 1,500 ETL 4/140 L 1,600 ETL 4/200 L 1,700 ETL 4/300 L 1,800 Illustration shows R. H. version short lip in front (see page 6)...

Open the catalog to page 13

All VAHLE catalogs and technical brochures

  1. APOS Optic

    12 Pages

  2. SMGM

    20 Pages

  3. SMGX

    20 Pages

  4. CPS 20kHz

    24 Pages

  5. CPS 140kHz

    32 Pages

  6. Festoon system