Catalog excerpts
Viscosity & Density Measurement Enabling Mass Flow Measurement
Open the catalog to page 1Most of the operating costs of a ship are fuel related. Therefore it is very important to use fuel in the most efficient way. Calculated Carbon Aromaticity Index (CCAI) is the index for the ignition quality of residual fuel oil and is calculated from density and viscosity of the fuel. The measurement and control of the viscosity and density ensures an improved combustion efficiency preventing engine damage and reduction of fuel and maintenance costs. ViscoSense®3D is able to measure inline the actual dynamic viscosity and density of a large range of liquids. The unique measuring principle...
Open the catalog to page 2Cost-effective solution To enable mass flow measurement, only a small upgrade of your current system Is required. *®l ^ = mass flow One ViscoSense®3D can be combined with one or multiple Flowmeters in the same fuel system, independent of configuration. Fuel consumption measurement by VAF Instruments’ Positive Displacement Flowmeters in combination with density measurement by the ViscoSense®3D is a cost-effective solution that enables mass flow measurements with highest accuracy, reliability and repeatability. Features and benefits As a result of the torsional vibration technique, the flow...
Open the catalog to page 30-25/50 mPa.s (other ranges on request, max. 1000 mPa.s) 750-1100 g/l (other ranges on request) 0- 200°C Sensor_ Viscosity range Density range Temperature range Maximum operating temperature Temperature transmitter Viscosity accuracy Density accuracy Temperature accuracy Sensor material Coating material Protection class Cable length Weight PT100 element ± 2% instantaneous or 0.5 mPa.s ± 0.1% instantaneous or 1 g/l ± 1°C Stainless steel 316L / Ni-alloy Diamond Like Carbon (DLC) IP65 5 m integrated 1 kg Interface box Viscosity, density and temperature output Bus Power supply Power consumption...
Open the catalog to page 4Sensor housing_ Material Ductile iron Flange connections Standard DN50 (2"), DIN, ANSI or JIS; other sizes on request ViscoSense® housing For Viscotherm replacement a retrofit housing is available. Please refer to Information Bulletin 732. 5
Open the catalog to page 550 (REQUIRED CONNECTION SPACE) 250
Open the catalog to page 6Sensor housing FIXED CABLE LENGTH 5m -0,1m ViscoSense® housing WITHDRAWAL SPACE Sensor housing for Viscotherm replacement Housing+VAF logo 13-4-2011 Wr COLUMN VAF ADDED 25-1-11 Wr DESCRIPTION DATE PAR REVISION DIM DRAWING ViscoSense Sensor (dim. ViscoTherm) 20 mm DIMENSIONS IN mm THIS CONFIDENTIAL DOCUMENT IS THE SOLE PROPERTY OF VAF INSTRUMENTS IT MUST NOT BE REPRODUCED IN ANY MATERIAL FORM, OR ITS CONTENTS DIVULGED TO A THIRD PARTY WITHOUT PRIOR WRITTEN AUTH
Open the catalog to page 7All copyrights reserved | PB-774-GB-0917 Supersedes PB-774-GB-0217 1. Basic system designation: ViscoSense®3D 2. Application: O fuel viscosity and density measurement O fuel viscosity control O Viscotherm retrofit O ViscoSense® retrofit O mass flow measurement (please consult factory) O bunker receipt / supply (please consult factory) 8. Flow rate* [m3/h]: * For fuel consumption, please specify flow rate of circulation pump 9. Nominal diameter of piping: 10. Flange type: O DIN PN 10 bar O ANSI RF 150 lbs O JIS 10 K O DIN PN 16 bar O ANSI RF 300...
Open the catalog to page 8All VAF Instruments catalogs and technical brochures
-
VAF Instruments
20 Pages
-
Oil Blending Systems