Technical Data Sheet va-Q-vip F Product Description va-Q-vip F is a microporous insulation material based on fumed silica. The vacuum insulation panel is approved for general construction purposes in accordance with approval number Z-23.11-1658 and ETA-17/0926 of the "Deutsches Institut für Bautechnik (DIBT)". va-Q-vip F elements are unique because of their rectangular edges and corners (va-Q-seam) whereas individual elements can be joined together almost seamlessly. In general rectangular panels are produced but various shapes (trapeze, triangle, corner section) are possible on request. The va-Q-vip F can be used in buildings according to the application areas DAD, DAA, DZ, DI, DEO, WAB, WH and WI according to DIN 4108-10, table 1 (floors, flat roofs, ceilings, top floor ceilings, exterior insulation behind panelling, walls, insulation in wood frame construction). Hereby our application-specific, laminated versions va-Q-vip F XPS and vaQ-vip F GGM are obtainable. Enhanced usable room area due to thinner insulation material Smooth edges and no foil overlaps due to patented va-Q-seam technology Various standard sizes on stock Approved for general construction purposes according to Z-23.11-1658 and ETA-17/0926 Long lifetime due to optimized panel design 100 % quality control with the patented gas pressure measurement system (va-Q-check) Sustainable product (recyclable core material)

Open the catalog to page 1
va-Q-vip F - 2

Properties Thermal conductivity - initial value @ 10 °C* Thermal conductivity - design value incl. aging and edge effects Thermal conductivity ventilated design value incl. aging and edge effects U-Value - initial value @ 10 °C* U-Value - design value incl. aging and edge effects Internal gas pressure @ 20 °C Density ≤ 0.0043 W/(m∙K) (thickness ≥ 15 mm, at delivery) according to DIN EN 12667 0.007 W/(m∙K) (thickness ≥ 20 mm) 0.008 W/(m∙K) (thickness < 20 mm) 0.020 W/(m∙K) 0.22 W/(m²∙K) (thickness = 20 mm) 0.80 W/(m²∙K) (thickness = 10 mm) 0.14 W/(m²∙K) (thickness = 50 mm) ≤ 5 mbar (at...

Open the catalog to page 2
va-Q-vip F - 3

Testing standards Our va-Q-vip F panels are subjected to the according to internal test methods to confirm their exceptional properties: - Accelerated aging tests at 50 °C, 70 % relative humidity and 80 °C (dry) Thermal conductivity measurements λ(T), λ(p) according to DIN EN 12667 Long-time monitoring at room conditions (p(t), λ(t)) Fire protection test according to DIN 4102-1 / EN 11925-2 Measurement of the length- and point-related heat transition coefficient (thermal bridge effect, Ѱ-value) Remark: Please ask for preferred sizes and tolerances.

Open the catalog to page 3
va-Q-vip F - 4

Application-specific versions For the different application areas in construction sector additional application-specific versions of the va-Q-vip F are obtainable: application area 3 mm rubber granules (one-sided or both-sided) interior (walls, floors, ceilings, etc.) mainly floors Remark: Any desired combinations of the versions are available on request. The listed versions are approved for general construction purposes in accordance with approval number Z-23.11-1658 of the "Deutsches Institut für Bautechnik”.

Open the catalog to page 4
va-Q-vip F - 5

Legal Notes/Disclaimer The data presented in this technical data sheet are in accordance with the present state of our knowledge. All numbers and features proposed in this data sheet (e.g. lifetime) were determined under test conditions in the laboratory and therefore represent a nonbinding and purely scientific value. There are no guarantees associated with. Only the respectively agreed warranty period and warranty rights apply. To the extent permitted by law, all other warranties of any kind, whether express or implied, including, but not limited to the implied warranties of...