va-Q-shell

va-Q-shell

va-Q-shell

Product catalog summary
Description
va-Q-shell is a customized rigid shell insulation system designed for heat storage tanks to enhance energy efficiency, achieving EU regulation 812/2013 label ratings of A and A+. It consists of two PU half shells with integrated vacuum insulation panels (VIP) and features a tongue-and-groove assembly system. It can be adapted for various tank shapes and includes options for cut-outs and technical device fixation points.
Technical Properties
The standard properties include an outer diameter up to 2,000 mm, height up to 3,000 mm, and wall thickness up to 200 mm. The density of VIP is 160-230 kg/m³ and PU is 50-70 kg/m³. Thermal conductivity for VIP is < 0.0035 W/(m*K) and for PU is < 0.025 W/(m*K). The operating temperature range is 0 - 95 °C with relative humidity of 0 - 60%.
Performance Example
An example comparison shows va-Q-shell's superior performance over conventional PU and polyester fleece insulations. For a 300-liter steel tank, va-Q-shell achieves a minimal U-value of 0.13 W/(m²*K) and a total heat loss rate of 1.0 kWh/d, reaching an energy label of A, compared to B and C for PU and fleece respectively.
Safety Information
va-Q-shell complies with REACH regulation and OSHA standards, with no requirement for a safety data sheet. It contains no Substances of Very High Concern (SVHC) above 0.1% w/w.
Legal Notes / Disclaimer
The data provided are based on laboratory test conditions and are nonbinding. No guarantees are made beyond agreed warranty terms. Users are responsible for determining product suitability for their purposes, and the current version of the technical data sheet is available on the company's website.
See more

Catalog excerpts

va-Q-shell-1

Product Data Sheet va-Q-shell DESCRIPTION va-Q-shell is a customized, rigid shell insulation system for heat storage tanks. Its purpose is to increase the energy efficiency of tanks to a label rating of A and A+ according to the EU regulation 812/2013. The insulation consists primarily of two PU half shells with integrated vacuum insulation panels (VIP). The shell parts are assembled via a tongue-and-groove system. Cut-outs for piping, inspection ports and other connections are also provided. Baseplates or fixation points for technical devices like displays, sensors or external heat exchangers are available on request. va-Q-shell can be individually adapted for variously shaped hot water tanks. Author: Alexander Göbel

 Open the catalog to page 1
va-Q-shell-2

TECHNICAL PROPERTIES Standard properties are as listed below. Different dimensions or properties are available on request. Different inner or outer coatings and options for flange cut-outs are also available on request. Operating Temperature Operating Relative Humidity Wall thickness shells with diameters > 1,200 mm are split into three or more parts ² following DIN EN 12667 at 10 °C and at delivery Author: Alexander Göbel

 Open the catalog to page 2
va-Q-shell-3

PERFORMANCE EXAMPLE The va-Q-shell is a custom product. U-values and heat loss is case dependent and calculated accordingly. Support for calculations is available on request. The following section provides an exemplary comparison of va-Q-shell and conventional insulations made of pure PU or polyester fleece: Tank Specifications Storage Volume Tank Material Average Operating Temperature Connectors Flange Diameter A calculation including thermal bridge effects caused by connectors and joints results in the following performance: Polyester fleece Wall Thickness Minimal U-Value Total Heat Loss Rate...

 Open the catalog to page 3
va-Q-shell-4

SAFETY INFORMATION va-Q-shell is an article according to the REACH regulation (EC) No. 1907/2006 and the OSHA Hazard Communication Standard, 29 CFR Subpart 1910.1200(c). For articles, the preparation of a safety data sheet is not required. Even though this article is not subjected to any obligation to classify or label according to CLP regulation (EC) No. 1272/2008, the va-Q-tec AG provides a safety data sheet for the core material of va-Q-shell on request. Furthermore, the article contains no Substances of Very High Concern (SVHC) above the threshold 0.1% w/w. LEGAL NOTES / DISCLAIMER The data...

 Open the catalog to page 4

All Va-Q-tec AG catalogs and technical brochures

  1. va-Q-mic

    4  Pages

  2. va-Q-vip F

    5  Pages

  3. va-Q-vip

    4  Pages

  4. va-Q-plus

    4  Pages

  5. va-Q-pro

    4  Pages

  6. va-Q-pur

    4  Pages

  7. Construction

    19  Pages

  8. va-Q-steel

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.