Catalog excerpts
Technical data sheet va-Q-plus (Technics & Industry) Product Description va-Q-plus, the second generation of vacuum insulation panels, is a microporous insulation material based on fumed silica. The high-tech panel is produced at most recent and in-house developed production lines. The powdered core material and the specifically engineered foil technology are optimized for the use at high temperatures and ensure the outstanding insulation ability for the entire service life of the product. The typical fields of application are hot water tanks, district heating pipes, laboratory equipment and the automotive sector. Very good cost-performance ratio Temperature resistant up to 100 °C, temporary up to 130 °C Optional imprinting of rills enables an extremely high flexibility Best insulation value over the entire lifetime for insulation panels based on fumed silica Long lifetime because of optimized panel designs 100 % quality control with the patented gas pressure measurement system (va-Q-check) Sustainable product (recyclable core material)
Open the catalog to page 1Properties Thermal conductivity - initial value @ 10 °C* Thermal conductivity, ventilated @ 10 °C* < 0.0035 W/(m∙K) (at delivery) according to DIN EN 12667 0.020 W/(m∙K) according to DIN EN 12667 U-Value - initial value @ 10 °C* Area density Temperature resistance Moisture resistance 0 – 70 % relative humidity (until 50 °C) Storage stability Optimal storable @ 23 °C, 50 % rel. humidity Thermal shock resistance Specific heat capacity -75 – 80 °C according to DIN EN 60068-2-14 0 – 110 °C nach DIN EN 60068-2-14 0.8 kJ/kgK (at room temperature) Compressive strength at 10 % compression Depending...
Open the catalog to page 2Measures and tolerances width w in [mm] ≤ 300 > 300 - 500 > 500 length l thickness t thickness t thickness t in [mm] tolerances: l/w/t in [mm] tolerances: l/w/t in [mm] tolerances: l/w/t in [mm] in [mm] in [mm] in [mm] ≤ 10 Remark: Based on the unique production method, the panels are less thick at the edges and corners than in the center. The measures, tolerances and insulation values refer to the insulated area of the panel form one corner to another. Circulating the panel there is a 10 mm to 20 mm wide sealing seam. A typical panel measures 8 mm up to 30 mm. The smaller the panel the...
Open the catalog to page 3Legal Notes/Disclaimer The data presented in this technical data sheet are in accordance with the present state of our knowledge. All numbers and features proposed in this data sheet (e.g. lifetime) were determined under test conditions in the laboratory and therefore represent a nonbinding and purely scientific value. There are no guarantees associated with. Only the respectively agreed warranty period and warranty rights apply. To the extent permitted by law, all other warranties of any kind, whether express or implied, including, but not limited to the implied warranties of...
Open the catalog to page 4All Va-Q-tec AG catalogs and technical brochures
-
va-Q-mic
4 Pages
-
va-Q-shell
4 Pages
-
va-Q-vip F
5 Pages
-
va-Q-vip
4 Pages
-
va-Q-pro
4 Pages
-
va-Q-pur
4 Pages
-
va-Q-vip Floor
5 Pages
-
Construction
19 Pages
-
va-Q-shield VIP C
4 Pages
-
va-Q-tray lid (BC000520)
2 Pages
-
va-Q-case ½ Euro
1 Pages
-
va-Q-tainer XLx
4 Pages
-
va-Q-steel
5 Pages