1. Catalogs
  2. UWT GmbH
  3. Vibranivo® VN 1000 / Vibranivo® VN 2000 / Vibranivo® VN 5000 / Vibranivo® VN 6000

Vibranivo® VN 1000 / Vibranivo® VN 2000 / Vibranivo® VN 5000 / Vibranivo® VN 6000

Vibranivo® VN 1000 / Vibranivo® VN 2000 / Vibranivo® VN 5000 / Vibranivo® VN 6000
1 / 41 PagesView full catalog

Vibranivo® VN 1000 / Vibranivo® VN 2000 / Vibranivo® VN 5000 / Vibranivo® VN 6000

Product catalog summary
Safety Notes and Technical Support
Installation, maintenance, and commissioning of the level limit switch must be conducted by qualified personnel. The product should be used as per the manual, with attention to warnings about potential risks of electric shock, serious injury, or material damage. For technical support, contact UWT GmbH or your local supplier.
Introduction
The level limit switch is designed for monitoring levels in containers and silos, suitable for powdery and granulated bulk materials. It is applicable in industries such as building materials, food, plastics, timber, chemical, and mechanical engineering. The device can be mounted on the lateral container wall or from the top using an extension piece, with probe lengths extending up to 20 meters.
Technical Data
The switches are available in various housing versions, including standard and explosion-proof models. They feature adjustable sensitivity, vibration frequency, and signal delay. Electrical data includes connection terminals, cable entry specifications, and power supply requirements. Mechanical data covers housing materials, process connections, and operating conditions, such as ambient and process temperatures.
Approvals and Options
The devices come with a range of Ex-approvals for use in hazardous areas. Options include enhanced sensitivity and separate housing configurations.
Mounting and Electrical Installation
Instructions for mounting the device and performing electrical installations are provided to ensure proper setup and operation.
Signal Output and Diagnostics
The device features signal output options, including floating relay and open collector configurations, with built-in LED indicators for status monitoring.
Settings and Maintenance
Sensitivity settings can be adjusted in two levels, and regular maintenance is recommended to ensure optimal performance.
Notes for Hazardous Locations
Special considerations are provided for using the device in hazardous locations, ensuring compliance with safety standards.
Assembly and Disposal
Detailed assembly instructions for different models are included, along with guidelines for proper disposal of the device.
Technical Specifications
The document outlines the mechanical and operational specifications for the Vibranivo® level limit switch series VN 1000 / 2000 / 5000 / 6000. Key mechanical specifications include a lateral mechanical load of 600 N on oscillator rods, a maximum mechanical torque of 300 Nm for VN ..030 and 100 Nm for VN ..040, and a maximum tractive force of 2 kN for VN ..050. The maximum process pressure varies by model, with VN ..020, VN ..030, and VN ..040 supporting up to 16 bar, while VN ..050 supports up to 6 bar.
Environmental Conditions
The devices are suitable for outdoor use, withstanding relative humidity from 0 to 100% and altitudes up to 3,000 m for VN 1000/2000 and 2,000 m for VN 5000/6000. Transport and storage conditions are specified with temperature ranges from -40 to +80°C and humidity from 20 to 85%.
Approvals and Standards
The devices comply with various international standards and approvals, including CE/UKCA, FM/CSA, TR-CU, and EN 61010-1 for ordinary locations, and ATEX, UKEX, IEC-Ex, FM, CSA, TR-CU, INMETRO, KC, and CCC for hazardous locations. Compliance with EMC standards (EN 61326 -A1) and RoHS directive 2011/65/EU is also mentioned.
Installation and Safety Instructions
Installation guidelines emphasize the importance of proper mounting to avoid mechanical damage and ensure safety, especially in hazardous locations. Detailed instructions on mounting, sealing, and electrical connections are provided, including the use of PTFE sealing tape and grounding to prevent static charging.
Options and Accessories
Optional accessories include weather protection covers, sliding sleeves, mounting sets, signal lamps, and various plug types. Material compatibility and installation constraints for these accessories are specified, particularly in hazardous environments.
Operational Considerations
The document advises on the detection of solids in water, specifying that only certain models (VN 1020/1030/5020/5030) are suitable for this application. It also discusses the impact of environmental factors on product lifetime and provides guidelines for handling and maintenance to ensure device longevity and reliability.
Signal Output and Diagnosis
The Vibranivo® series VN 1000/2000/5000/6000 level limit switches provide signal output through electronic modules with settings of 8/16 mA or 4-20 mA. The output indicates the vibration signal quality, allowing for material build-up detection and vibration behavior evaluation using a PLC or data logger.
Sensitivity Settings
Sensors are factory preset, but sensitivity can be adjusted for materials prone to caking. The VN 1000/5000 and VN 2000/6000 models have different minimum bulk density settings, with options for enhanced sensitivity using a potentiometer.
Changing the Electronic Module
Instructions are provided for safely replacing electronic modules, emphasizing the importance of using intrinsically safe marked modules where required. Maintenance includes frequent checks for mechanical damage, proper sealing, and cleaning with compatible agents.
Zone Classification and Safety
The document outlines the permissible zones for use in hazardous locations, detailing equipment protection levels for dust and gas applications. Specific conditions for electrostatic charge prevention and flameproof joint maintenance are highlighted.
Temperature and Pressure Specifications
Temperature ratings and maximum surface temperatures are provided for both intrinsic and non-intrinsic safe modules. The document clarifies that ATEX approvals cover atmospheric pressure only, with deviations requiring expert assessment.
Assembly Instructions
Detailed instructions for assembling the VN ..040 model with standard housing are included, emphasizing the importance of matching thread types and ensuring mechanical stability.
Overview
This document provides technical specifications and assembly instructions for the Vibranivo® level limit switch series VN 1000 / 2000 / 5000 / 6000. It includes detailed procedures for assembly, cable preparation, and sealing requirements.
Specifications
  • Tightening torque for assembly is 50 Nm.
  • Use a 36 mm (1.42") open-end wrench for attaching components.
  • Sealing requirements include IP67 or NEMA 4 standards, with specific instructions for G and NPT versions.
Assembly Instructions
  • Ensure correct threading type (G or NPT) for extension tubes and oscillating pieces.
  • For G version, use original O-rings from the manufacturer to ensure proper sealing.
  • For NPT version, use temperature-resistant sealing for up to 150°C (302°F) with a maximum thickness of 0.2 mm (0.008").
Cable Preparation and Connection
  • Shorten sensor cables to specified lengths (150 mm or 80 mm) and prepare as shown in diagrams.
  • Connect sensor cables to terminal connection pieces and ensure all terminals are tightly screwed in.
  • Use shrink hoses to cover exposed wires and ensure proper insulation.
Reassembly Instructions
  • When removing and reassembling connection cables, follow the factory-provided cable situation as a sample.
  • Ensure the cable gland is tightly closed to maintain ingress protection standards.
Disposal
  • The product is made of recyclable materials, and recycling should be done by a specialized company.
See more

Catalog excerpts

Vibranivo® VN 1000 / Vibranivo® VN 2000 / Vibranivo® VN 5000 / Vibranivo® VN 6000-1

Level limit switch Series VN 1000 / 2000 / 5000 / 6000 Technical information / Instruction manual 2 Page Safety notes/ Technical support 2 --------------------------------------------------------------------------------------------------------- Introduction 3 --------------------------------------------------------------------------------------------------------Technical data 4 Electrical installation 18 --------------------------------------------------------------------------------------------------------Signal output/ Diagnostics 24 Maintenance 30 --------------------------------------------------------------------------------------------------------Notes for use in Hazardous Locations --------------------------------------------------------------------------------------------------------Assembly VN ..040 34 --------------------------------------------------------------------------------------------------------Assembly VN ..020/ VN ..030 with separate housing Subject to technical change and price change. We assume no liability for typing errors. Different variations to those specified are possible. Please contact our technical consultants.

 Open the catalog to page 1
Vibranivo® VN 1000 / Vibranivo® VN 2000 / Vibranivo® VN 5000 / Vibranivo® VN 6000-2

Level limit switch Series VN 1000 / 2000 / 5000 / 6000 Technical information / Instruction manual Safety notes / Technical support Installation, maintenance and commissioning must be carried out only by qualified technical personnel. The product must be used only in the manner outlined in this instruction manual. 3 Special attention must be paid to warnings and notes as follows: Relates to a caution symbol on the product and means, that a failure to observe the necessary precautions can result in death, serious injury and/ or considerable material damage. Relates to a caution symbol on the product:...

 Open the catalog to page 2
Vibranivo® VN 1000 / Vibranivo® VN 2000 / Vibranivo® VN 5000 / Vibranivo® VN 6000-3

Level limit switch Series VN 1000 / 2000 / 5000 / 6000 Technical information / Instruction manual Applications The device is used for level monitoring in all types of containers and silos. It can be used with all powdery and granulated bulk materials that do not show a strong tendency to form crusts or deposits. Detection of solids in water is also possible. The units can be delivered with a wide range of Ex-approvals for use in Gas and Dust Hazardous Areas. A selection of fields of application: • Building materials industry lime, styrofoam, moulding sand, etc. Food industry milk powder, flour,...

 Open the catalog to page 3
Vibranivo® VN 1000 / Vibranivo® VN 2000 / Vibranivo® VN 5000 / Vibranivo® VN 6000-4

Level limit switch Series VN 1000 / 2000 / 5000 / 6000 Technical information / Instruction manual Technical data Housing versions Explosionproof with increased safety terminal box

 Open the catalog to page 4
Vibranivo® VN 1000 / Vibranivo® VN 2000 / Vibranivo® VN 5000 / Vibranivo® VN 6000-5

Level limit switch Series VN 1000 / 2000 / 5000 / 6000 Technical information / Instruction manual Technical Data Temperature extended shaft (pos.3 2) with option: enhanced sensitivity (pos.26 x) Vibrasil 70 (pos.26 a) Vibrasil 90 (pos.26 b) * see page 6 bottom right ** Welding seam max. ø43.8 mm (ø1.72") * see page 6 below right hand ** Welding seam max. ø43.8 mm (ø1.72") Temperature extended shaft (pos.3 2) With option separate housing (pos.26 1/ pos.26 2)

 Open the catalog to page 5
Vibranivo® VN 1000 / Vibranivo® VN 2000 / Vibranivo® VN 5000 / Vibranivo® VN 6000-6

Level limit switch Series VN 1000 / 2000 / 5000 / 6000 Technical information / Instruction manual Technical data Extension tube NOT part of delivery * see bottom right ** Welding seam max. ø43.8 mm (ø1.72") * Length of oscillating rods 8 increased vibrating surface (aluminium) with option Enhanced sensitivity / Vibrasil® 90 (pos.26 x / pos.26 b) with option Vibrasil® 70 (pos.26 a) * see right ** Welding seam max. ø43.8 mm (ø1.72")

 Open the catalog to page 6
Vibranivo® VN 1000 / Vibranivo® VN 2000 / Vibranivo® VN 5000 / Vibranivo® VN 6000-7

Level limit switch Series VN 1000 / 2000 / 5000 / 6000 Technical information / Instruction manual Technical data Electrical data Connection terminals Cable entry M20 x 1.5 screwed cable gland NPT 1/2" conduit connection NPT 3/4” conduit connection (only VN 5000/ 6000) Clamping range (diameter) of the factory provided cable glands: M20 x 1.5: 6 .. 12 mm (0.24 .. 0.47") Signal delay Sensor free -> covered ca. 1 sec Sensor covered -> free ca. 1 .. 2 sec On the electronic module "Universal voltage Relay DPDT” is an electronic delay, adjustable up to 30 sec. Safety operation (FSL,FSH) Switchable for...

 Open the catalog to page 7
Vibranivo® VN 1000 / Vibranivo® VN 2000 / Vibranivo® VN 5000 / Vibranivo® VN 6000-8

Level limit switch Series VN 1000 / 2000 / 5000 / 6000 Technical information / Instruction manual Technical data Electronic modules Power supply Non intrinsic safe version: 12.5 .. 36 V DC +0% Intrinsic safe version: 12.5 .. 30V DC +0% Max. ripple of power supply Installed load max. 30 mA (for non intrincic safe application) Signal output Load current: min. 10 mA max. 500 mA permanent max. 2 A <200 ms max. 5 A <50 ms Voltage drop on the electronic module: max. 7 V with closed electric circuit. Setting 4-20 mA: Output current depends on the vibration amplitude of the fork between 6 mA for damped...

 Open the catalog to page 8
Vibranivo® VN 1000 / Vibranivo® VN 2000 / Vibranivo® VN 5000 / Vibranivo® VN 6000-9

Level limit switch Series VN 1000 / 2000 / 5000 / 6000 Technical information / Instruction manual Technical data Mechanical data Housing Aluminium housing, powder coated RAL 5010 gentian blue Seal between housing and lid: NBR Seal between housing and process connection: NBR Nameplate: polyester film Cable for separate housing Silicone elastomer, ø10 mm (ø0.39"), surface resistance <10 9 Ohm, UV-resistent, min. bending radius 50 mm (1.97") Degree of protection * IEC/ EN 60529. For version with plug the type of protection can be lower (see option plug/ page 13). Process connection/ extension L...

 Open the catalog to page 9
Vibranivo® VN 1000 / Vibranivo® VN 2000 / Vibranivo® VN 5000 / Vibranivo® VN 6000-10

Level limit switch Series VN 1000 / 2000 / 5000 / 6000 Technical information / Instruction manual Technical data Process temperature -40°C .. +150°C (-40 .. +302°F) VN ..020/ VN ..030 and VN ..040 Mounting for process temperature up to 150°C (302°F): see drawing -40°C .. +110°C (-40 .. +230°F) VN ..020/ VN ..030 with Ex approval and separate housing (price list option 26.1, 26.2) -25°C .. +80°C (-13 .. +176°F) VN ..050 For versions with Ex-approvals: see remarks on page 33. ca 75 g/l (4.5 lb/ft3) Standard version ca 20 g/l (1.2 lb/ft3) Enhanced sensitivity (pos. 26x) Vibrasil® 90 (pos. 26b) <...

 Open the catalog to page 10

All UWT GmbH catalogs and technical brochures

  1. DK value

    8  Pages

  2. Mononivo® 4000

    25  Pages

  3. NivoBob® 3000

    41  Pages

  4. NivoCapa® 8000

    27  Pages

  5. NivoBob® 4000

    31  Pages

  6. RFnivo® 3000

    44  Pages

  7. RFnivo® 8000

    39  Pages

  8. Rotonivo® 4000

    21  Pages

  9. RFnivo® 8000

    2  Pages

  10. RFnivo® 3000

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.