
Group: UWT-Group

Catalog excerpts

SOLUTIONS FOR THE BUILDING / CEMENT INDUSTRY
Open the catalog to page 1
As an owner-managed, medium-sized company, with an international sales network in over 90 Ac c ording t o t he high s t an dards of vari ous countries and personal contacts available locally, indust ries, U WT’s t eam provi de s ext e n s i ve UWT stands for a sustainable partnership at eye support for indiv idual re qui re m e nt s . level - globally and regionally. Cust omer-orient ed plan n i n g e n abl e s t h e dev elopment of t ailore d s ol ut i on s t h at are point, and interface measurement. We measure bulk solids, from t he finest powder t o c oarse, Thanks t o in-house produc t...
Open the catalog to page 2
B U IL D IN G M AT E R IA L S A N D C E M E N T IN D U ST RY Traditional craftsmanship meets innovation Alternative raw materials, including by- in the building materials and cement sector. products from other industries such as fly In a modern world that increasingly focuses ash or blast furnace slag, make a significant on sustainable construction and resource contribution to reducing CO₂ emissions and conservation, cement and other building conserving resources. materials play a crucial role. From residential buildings to large-scale projects and In addition, innovative concepts such as...
Open the catalog to page 3
LE V EL A ND PO INT LE VE L MEAS UREM EN T ON A BU L K M ATERIAL STOCKPILE m ateria ls for ce ment p ro d u c t i o n . L i m es t one is ex t ra ct e d t h rough m i n i n g a n d t h en c r u she d to prod u ce lim e s t o n e a ggregat e. C l ay i s
Open the catalog to page 4
< 10 M | 33 FT Through blasting, large boulders are extracted from solid rock and then crushed into gravel, chippings, or sand using jaw and roller crushers. Reliable level measurement and point level detection are crucial for optimising material flow, minimising crusher wear, and ensuring efficient operations. Non -cont a ct l ev el m ea s u rem ent tech n olog y
Open the catalog to page 5
STORAGE SILO FOR GROUND RAW A ND AG G REG ATE MATE RIALS su ch a s lim e s t on e , s a n d s t o n e, c l ay, f ly a sh, soot, or coa l d u s t a re s t o red a s p owd er i n storag e s ilos . To a c h i ev e t h e o pt i m a l m at eria l
Open the catalog to page 6
LE V EL A ND PO INT LE VE L MEAS UREM EN T AT T HE C O N V E YOR TR ANSFE R POINT with in t h e conv ey i n g sys t em a n d c o m p en sate for fl uct u at ion s in q u a nt i t y. To p rev ent over fi llin g a n d eff i c i ent ly c o nt ro l t h e m at e ria l
Open the catalog to page 7
LE V EL A ND PO INT LE VE L D ET EC TION IN C L I NKER PRODUCTION kil n at ex t re m e ly h i gh t em p erat u res of u p to 1 200 ° C / 2 19 2 ° F. Th i s p ro c es s , kn ow n a s cl inker p rod u ct ion , c reat es a c o a rs e- gra i ne d Non -cont a ct l ev el m ea s u rem ent tech n olog y Re lia b le p roce s s i nt egrat i o n (U WT Leve lA p p)
Open the catalog to page 8
sig n ifica nt a m ou nt s of en ergy, oft en u s i n g alter n at iv e fu e ls s u c h a s wa s t e o i l s o r solvent s . Give n t he h i gh en ergy c o s t s , p recise l evel a n d p oint lev el m ea s u rem ent i n s t o ra ge tanks is e s s e nt ia l t o en s u re a rel i a b l e s u p p ly an d opt im is e t h e ef f i c i en cy of t h e p ro c es s.
Open the catalog to page 9
P O I N T L EVEL ME ASURE ME NT I N T HE EL ECTROSTAT IC P REC I PITATOR as l im e s t on e a n d c l ay a re p ro c es s ed at ex treme ly h ig h t e m p erat u res a n d f l u e ga se s conta in in g fin e p a rt i c l es a re gen erat ed . The se precip it at or a n d c o l l ec t ed i n h o p p ers . To ensu re s m oot h op erat i o n a n d rel i a b l e sys te m control, t h e u s e of p rec i s e p o i nt l ev el sensors is e s s e nti a l .
Open the catalog to page 10
in l arg e b u n ke rs o r s i l o s b efo re f u rt h er proce s s in g . P re cise a n d rel i a b l e p o i nt l ev e l detec t ion e n s u re s t h e s m o ot h o p erat i o n LINKER BUNKER P O I N T L EVEL ME ASURE ME NT FOR CL INKER STORAGE
Open the catalog to page 11
P NEU M ATIC CONV E YING powd e re d or g ra n u l a r c o n s t r u c t i o n m at er ia ls over l on g d is t a n ces . Us i n g c o m p res s ed a i r, the m at e r ia ls a re d el i v ered t o p ro c es s i n g areas . P re s s u re co nv ey i n g v es s el s en s u re a continu ou s m at e ri a l s u p p ly, w h i l e p o i nt l eve l sensors a ccu rat e ly m o n i t o r f i l l l ev el s a n d
Open the catalog to page 12
LE V EL A ND PO INT LE VE L MEAS UREM EN T IN T HE C EM E N T STOR AGE SILO CEMENT Me asuring Rang e to ens u re efficie nt f u rt h er p ro c es s i n g o r del iver y. P re cis e l ev el a n d p o i nt l ev el s en so rs are es s e nt ia l for t ra n s p a rent i nv ent o r y
Open the catalog to page 13
the con s t r u ct ion s i t e. Prec i s e p o i nt l ev el sensors cont rol t he f i l l i n g p ro c es s , p rev ent over fi llin g , a n d e n s u re ef f i c i ent a n d s afe
Open the catalog to page 14
of mine ra ls , rock d u s t , a n d b i t u m en – a binder d e r iv e d fro m p et ro l eu m . Th i s m u lt istag e p roce s s t a kes p l a c e i n s p ec i a l ly desig n e d a s p h a lt m i x i n g p l a nt s . Th e b i t u me n is store d in h e at ed t a n ks t o en s u re i t s fl uidi t y. B it u m e n b ec o m es p u m p a b l e at tem perat u re s of 1 2 0 °C / 24 8 °F, w h i c h i s why the te m p e rat u re s i n t h e t a n k c a n rea c h u p to
Open the catalog to page 15
P O I N T L EVEL ME ASURE ME NT I N T HE COL D DRAW SYSTE M ch ipp in g s a re s t ored i n t h e c o l d c o nv ey i n g system a ccord in g t o t h ei r a ggregat e s i ze. The sys t e m e n s u res t h at t h e m at er i a l s a re
Open the catalog to page 16
h ig h e s t p oint of t h e s c reen i n g p l a nt u s i n g an el evat or. Th e m at er i a l i s i nt ro d u c ed i nt o ILLING CHUTE
Open the catalog to page 17
MAT E R IAL S EPARATION I N S C REENING PLANT enabl e efficie nt o p erat i o n .
Open the catalog to page 18
LE V EL A ND L IMIT LE V E L MEAS UREM EN T IN T HE STO RAG E S ILO FOR ROCK FLOUR
Open the catalog to page 19
LE V EL L IM IT ME ASURE ME NT W HEN WEIGH I NG T H E COM PONENT MIXT URE < 2 M | 6 .6 F T Depending on the desired asphalt composition, the raw m at e r ia ls a re m i xed i n d i f ferent p ro p o rt i o n s . Th e m i n e ra l s c a l e a n d f i l l e r scal e p lay a ce nt ra l ro l e i n wei gh i n g t h e require d q u a nt it ies a c c o rd i n g t o t h e m i x i ng recipe. Point lev el s en s o rs en s u re ef f i c i ent
Open the catalog to page 20All UWT GmbH catalogs and technical brochures
-
NivoRadar ® 7000
2 Pages
-
NivoRadar® NR 3000
2 Pages
-
NivoRadar® NR 8000 en
2 Pages
-
NivoTec® Visualisation
2 Pages
-
Product-Overview UWT 2024-12
36 Pages
-
Product Matrix en
2 Pages
-
Level limit switch RFnivo® 3000
44 Pages
-
Level limit switch RFnivo® 8000
39 Pages
-
Radar Flyer New 2024
2 Pages
-
Solids - Liquids at a glance
2 Pages
-
Highlight NivoRadar® 4000 en
1 Pages
-
NivoCapa® NC 8000
2 Pages
-
Vibranivo® VN 4000
2 Pages
-
Vibranivo® VN 2000 / VN 6000
2 Pages
-
Vibranivo® VN 1000 / VN 5000
2 Pages
-
RFnivo® 8000 Product Leaflet
2 Pages
-
Rotonivo® RN 4000
2 Pages
-
Rotonivo® RN 3000 / 6000
2 Pages
-
NivoGuide® NG 3000
2 Pages
-
NivoBob® NB 4000
2 Pages
-
NivoBob® NB 3000
2 Pages
-
Capanivo® CN 4000
2 Pages
-
Capanivo® CN 8000
2 Pages
-
Solutions for the Grain industry
26 Pages
-
Vibrasil®70/90 Level switch
2 Pages
-
Solutions for the Power Industry
28 Pages
-
Solutions for the Steel Industry
26 Pages
-
DK value
8 Pages
Archived catalogs
-
Flyer Solids / Liquids
2 Pages