Safety Notes and Technical Support
Installation, maintenance, and commissioning of the RN 4000 level limit switch should be conducted by qualified personnel. Adherence to the manual and safety warnings is crucial. For technical support, contact UWT GmbH or your local supplier.
Introduction
The ROTONIVO RN 4000 is an electromechanical level limit switch designed for monitoring bulk goods in industries such as building materials, plastics, timber, and chemicals. It can be installed laterally or from the top of a container.
Function
The device operates with a measuring vane driven by a synchronous motor. When covered by material, the motor stops, indicating a "covered" status. It includes an adjustable delay for signal output and a fail-safe alarm option for fault detection.
Technical Data
The RN 4000 offers various vane types and materials, with aluminum or plastic process connections. It operates within specific temperature and pressure ranges and is suitable for outdoor use. Electrical specifications include connection terminals, cable entry, and isolation details.
Approvals
The device is certified for use in both non-hazardous and hazardous locations, with approvals such as ATEX, UKEX, and IEC-Ex. It complies with EMC and RoHS directives.
Options
Optional features include weather protection covers, rope extensions, and signal lamps, enhancing functionality and adaptability to different environments.
Mounting
Proper installation is essential to maintain process pressure and chemical resistance. The device should be mounted away from incoming material and silo walls, with attention to torque specifications and sealing requirements.
Electrical Installation
Electrical connections must follow specified guidelines for safe and effective operation. Detailed instructions for wiring and signal output configurations are provided in the manual.
Signal and Alarm Output
The RN 4000 offers configurable signal outputs and alarm settings to alert users of material coverage and device status.
Settings Sensitivity
Sensitivity settings can be adjusted to accommodate different material densities and flow characteristics.
Maintenance
Regular maintenance is recommended to ensure optimal performance and longevity of the device.
Notes for Use in Hazardous Locations
Special precautions and installation regulations must be followed when using the device in hazardous areas.
Disposal
Proper disposal procedures should be followed to comply with environmental regulations.
Technical Specifications
The document provides detailed specifications for the Rotonivo® RN 4000 level limit switch, including mounting options, electrical installation, and power supply requirements. The device supports AC, DC, and universal voltage versions with specific power ratings and fuse requirements.
Mounting and Installation
Various mounting configurations are described, including horizontal and vertical setups with specific recommendations for protective angles and vane types. Emphasis is placed on adhering to local electrical regulations and ensuring proper grounding to prevent static charging.
Electrical Installation
Key guidelines include using approved power supplies, ensuring proper cable gland specifications, and following wiring diagrams. The need for RCCB protection and strain relief for field wiring cables is highlighted.
Signal and Alarm Output
The RN 4000 features micro switch or relay outputs with specific voltage and current ratings. It includes fail-safe alarm options and describes the switching logic for full and empty detector settings.
Maintenance and Safety
Regular maintenance checks are recommended to ensure safety and functionality, especially in hazardous locations. Procedures for cleaning, function testing, and the importance of not opening the lid while circuits are live are outlined.
Zone Classification and Hazardous Locations
The device is suitable for use in various dust application zones with specific equipment protection levels. Guidelines for avoiding electrostatic charges and details on temperature ratings for safe operation are included.
Disposal and Recycling
The document advises on recycling the product through specialized companies and provides information on the materials used in the device.
See more

Catalog excerpts

Rotonivo® 4000-1

Level limit switch Series RN 4000 Technical information / Instruction manual 2 Page Safety notes/ Technical support 2 --------------------------------------------------------------------------------------------------------- --------------------------------------------------------------------------------------------------------Mounting 11 --------------------------------------------------------------------------------------------------------Electrical installation 13 --------------------------------------------------------------------------------------------------------Signal and Alarm output 16 --------------------------------------------------------------------------------------------------------- Settings sensitivity 18 --------------------------------------------------------------------------------------------------------Maintenance 19 --------------------------------------------------------------------------------------------------------Notes for use in Hazardous Locations Subject to technical change We assume no liability for typing errors. Different variations than specified are possible. Please contact our technical consultants.

 Open the catalog to page 1
Rotonivo® 4000-2

Level limit switch Series RN 4000 Technical information / Instruction manual Safety notes / Technical support Installation, maintenance and commissioning must be carried out only by qualified technical personnel. The product must be used only in the manner outlined in this instruction manual. 3 Special attention must be paid to warnings and notes as follows: WARNING Relates to a caution symbol on the product: A failure to observe the necessary precautions can result in death, serious injury and/ or considerable material damage. Relates to a caution symbol on the product: Risk of electric shock...

 Open the catalog to page 2
Rotonivo® 4000-3

Level limit switch Series RN 4000 Technical information / Instruction manual Applications The ROTONIVO is an electromechanical Level limit switch and is used for level monitoring of bulk goods. The units can be delivered with Ex-approvals for use in Hazardous Areas. Selected applications: The ROTONIVO is normally screwed into the lateral container wall so that it is level with the filling height to be registered and monitored. The device can also be mounted from the top of the container. In this case an extension piece is used to mount the probe level with the height to be registered (full detector)....

 Open the catalog to page 3
Rotonivo® 4000-4

Level limit switch Series RN 4000 Technical information / Instruction manual A measuring vane is driven by a synchronous motor. The bearing of the motor inside the housing allows it to swing. The motor is fixed to a switching lug. Signal output delay The version "universal voltage" and "PNP" has an integrated adjustable delay for the signal output. If the vane is uncovered, a spring pulls the motor and switching lug to the left position (figure 1). Option fail safe alarm With the fail safe alarm it is possible to recognize a fault of the unit in time and to initiate an alarm relay. The following...

 Open the catalog to page 4
Rotonivo® 4000-5

Level limit switch Series RN 4000 Technical information / Instruction manual Technical Data code A boot shaped vane 40 x 98 to lead in 1½“ socket (length of socket max. 40 mm (1.57”)) Material process connection: * aluminum ** plastics code K hinged vane 98 x 200 double sided code D boot shaped vane 35 x 106 b=28 mm (1.1") for 1"/ M32 x 1.5 to lead in 1¼“ socket (length of socket max. 40 mm (1.57”)) code S hinged vane 98 x 100 single sided code R boot shaped vane 28 x 98 to lead in 1“ or M32 x 1.5 socket (Socket length max. 40 mm (1.57")) code J boot shaped vane 26 x 77 Insertion of the hinged...

 Open the catalog to page 5
Rotonivo® 4000-6

Level limit switch Series RN 4000 Technical information / Instruction manual Technical Data Electrical data Connection terminals Cable entry M20 x 1.5 screwed cable gland Clamping range (diameter) of the factory provided cable glands: M20 x 1.5: 6 .. 12 mm (0.24 .. 0.47"") Protection class Overvoltage category Pollution degree Power supply Installed load Signal and alarm output Power to signal and alarm output: 2,225 Vrms Indicating light By built-in LED (not with AC version) Mechanical data Housing Plastics PA6 GF, RAL 5010 gentian blue Seal between housing and lid: NBR Seal between housing...

 Open the catalog to page 6
Rotonivo® 4000-7

Level limit switch Series RN 4000 Technical information / Instruction manual Technical Data Operating conditions Ambient temp. (housing) Process temperature Min. powder density/ Sensitivity see section “Sensitivity” on page 18 Signal delay Version Sensor free -> covered* Sensor covered -> free Universal voltage ca. 1.5 sec + 0 .. 20 sec adjustable ca. 0.2 sec + 0 .. 60 sec adjustable *after blocking of the measuring vane Features of bulk material Max. permitted mechanical torque (lateral) Process connection aluminium: Process connection plastics: Protective measures in case of high loading: mounting...

 Open the catalog to page 7
Rotonivo® 4000-8

Level limit switch Series RN 4000 Technical information / Instruction manual Non-hazardous Locations Hazardous Locations * ATEX UKEX IEC-Ex TR-CU INMETRO CCC RoHS conform According to directive 2011/65/EU and Statutory Instruments S.I. 2012/3032 Pressure Equipment Directive (2014/68/EU) As the equipment does not have pressure-bearing housings of its own, it is not subject to the PED: - as “pressure accessory” (see 2014/68/EU Art. 2 (5) and PED Guidelines A-08, A-40) - as “safety accessory” (see 2014/68/EU Art. 2 (4) and PED Guidelines A-20, A-25) Dust explosion Dust explosion Dust explosion Dust...

 Open the catalog to page 8
Rotonivo® 4000-9

Level limit switch Series RN 4000 Technical information / Instruction manual Weather protection cover If the measuring device is used outdoors, the use of the weather-protection-cover is recommended. It protects the device from all atmospheric influences such as: • rain water • condensation water • excessively high temperatures due to insolation • excessively low temperatures in winter Material: PE, weather and temperature stable For use in Hazardous Locations: only permitted for zone 22 Flat gasket On the face sealing of the process connection thread. Incl. sealing face for version with process...

 Open the catalog to page 9

All UWT GmbH catalogs and technical brochures

  1. DK value

    8  Pages

  2. Mononivo® 4000

    25  Pages

  3. NivoBob® 3000

    41  Pages

  4. NivoCapa® 8000

    27  Pages

  5. NivoBob® 4000

    31  Pages

  6. RFnivo® 3000

    44  Pages

  7. RFnivo® 8000

    39  Pages

  8. RFnivo® 8000

    2  Pages

  9. RFnivo® 3000

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.