Level monitoring system NivoTec® NT 4000
10Pages

{{requestButtons}}

Catalog excerpts

Level monitoring system NivoTec® NT 4000 - 1

Level monitoring system NT 4000 series Selection list Overview NT 4500/ NT 4600 2 ------------------------------------------------------------------------------------------------------------NT 4500 4 Level monitoring and visualisation via web server ------------------------------------------------------------------------------------------------------------NT 4600 6 Level monitoring and visualisation via touch panel ------------------------------------------------------------------------------------------------------------NT 4700 8 Level display for one silo ------------------------------------------------------------------------------------------------------------NT 4900 9 Digital display ------------------------------------------------------------------------------------------------------------Accessories 10 Subject to change. All dimensions in mm (inches). By publishing this selection list all other lists become invalid. All prices in Euro (€) or USD ($), excluding VAT. We assume no liability for typing errors. All EURO prices are EXW Betzigau, all USD prices are EXW Memphis, excluding packaging costs. Valid: From 01.01.2022 until 31.12.2022, unless otherwise agreed. Different variations to those specified are possible. Please contact our technical consultants.

Open the catalog to page 1
Level monitoring system NivoTec® NT 4000 - 2

Level monitoring system NT 4000 series Selection list Overview NT 4500 / NT 4600 Standardized Level monitoring system up to 30 silos Silo plant with continuous level measurement technology and full detectors Alarm "Silo full" Modbus converter 4-20 mA, full detector signal Modbus RTU Visualisation with touch panel Remote data enquiry Visualisation with PC via standard internet browser

Open the catalog to page 2
Level monitoring system NivoTec® NT 4000 - 3

Level monitoring system NT 4000 series Selection list Overview NT 4500 / NT 4600 Technical data Dimensions NT 4500/ NT 4600, Modbus converter: wall mounting NT 4500/ NT 4600, Modbus converter: steel plate Ingress protection Ambient temperature Power supply NT 4500/ NT 4600, Modbus converter: 115 V or 230 V 50/ 60 Hz (integrated power converter 24 V DC) NR 3000: supplied by Modbus converter 15 V or 230 V AC, connection is made on site Full detector: converter. connection either on NB 3000/ NB 4000 resp. Modbus In this case the supply voltage must be equal to NB 3000/ NB 4000 resp. Modbus...

Open the catalog to page 3
Level monitoring system NivoTec® NT 4000 - 4

Level monitoring system NT 4000 series Selection list NT 4500 Level monitoring and visualisation via web server - Standardised system up to 50 silos - Visualisation and operation via standard internet browser software - Software language: German or English - Password protected - Worldwide remote enquiry of the level - Data in percentage, height, volume or weight - Trend display, data storage, export via .csv - Evaluation of the analogue 4-20 mA signals of any sensors, as well as Modbus RTU of the UWT-systems - Different input signals within the same system is possible - Implementation of...

Open the catalog to page 4
Level monitoring system NivoTec® NT 4000 - 5

Level monitoring system NT 4000 series Selection list Control cabinet - max. number of silos Webserver without control cabinet, pre-wired on a top hat rail - max. 25 silos Webserver without control cabinet, pre-wired on a top hat rail - max. 50 silos Webserver in a control cabinet - max. 25 silos Webserver in a control cabinet - max. 50 silos Input signals of level sensors Modbus RTU (NB 3000/ NB 4000) 4-20 mA 2-wire (e.g. NivoRadar NR 3000), use of Modbus converter Price for each 4 silos

Open the catalog to page 5
Level monitoring system NivoTec® NT 4000 - 6

Level monitoring system NT 4000 series Selection list NT 4600 Level monitoring and visualisation via touch panel - Standardised system up to 15 silos - Visualisation and operation via 7" touch panel (coloured, 800 x 480 pixel) - Software language: German or English - Password protected - Data in percentage, height, volume or weight - Trend display, data storage - Evaluation of the analogue 4-20 mA signals of any sensors, as well as Modbus RTU of the UWT-systems - Different input signals within the same system is possible - Implementation of full detectors - Fill control via full alarm...

Open the catalog to page 6
Level monitoring system NivoTec® NT 4000 - 7

Level monitoring system NT 4000 series Selection list Control cabinet A Touch panel without control cabinet B Touch panel completely wired in a control cabinet Input signals of level sensors Modbus RTU (NB 3000/ NB 4000) 4-20 mA 2-wire (e.g. NivoRadar NR 3000), use of Modbus converter Price for each 4 silos Mixed used: Modbus RTU/ 4-20 mA 2-wire Price for each 4 silos with 4-20 mA units

Open the catalog to page 7
Level monitoring system NivoTec® NT 4000 - 8

Level monitoring system NT 4000 series Selection list NT 4700 Level display for one silo - Evaluation of the analogue 4-20 mA signal of any sensor - LED-Display in percentage, height, volume or weight (implements NT 4900) - Version for Nivobob NB 3000/ NB 4000 implements start button and indicator lamp when sensor weight is in the upper position - Simple operation Technical data Dimensions Wall mounting Ingress protection Ambient temperature Power supply NB 3000/ NB 4000: 230 V 50/ 60 Hz or 115 V 50/ 60 Hz or 24 V DC, connection is made on site 2-wire 4-20 mA : Power consumption Art.nr....

Open the catalog to page 8
Level monitoring system NivoTec® NT 4000 - 9

Level monitoring system NT 4000 series Selection list NT 4900 Digital display - Level display in percentage, height, volume or weight, freely programmable - LED display, 4 digits, 7 segment, yellow - Operation via front buttons - 4-20 mA input Technical data Dimensions Ingress protection Ambient temperature Power supply Power consumption Signal input 4-20 mA aktiv (Terminal 11 = +, Terminal 12 = GND) Programming example: 4mA relates to a display of 0,0 tons, 20 mA to 60,0 tons Following parameters are changed from the presets (procedure see exernal programming manual): d.CnF -> i.Typ = 4-20...

Open the catalog to page 9
Level monitoring system NivoTec® NT 4000 - 10

Level monitoring system NT 4000 series Selection list Accessories Terminal box Intermediate terminals for the wires leading to the silo (mounting e.g. on the silo frame). Applicable for cables of level (Modbus or 4-20 mA), limit switch, buzzer, reset button Technical data Dimensions steel plate Ingress protection Ambient temperature Terminal blocks 15 pieces grey, 5 pieces blue, 5 pieces green/ yellow; each terminal implements 3 cable inlets 2.5 mm2, mounted on top hat rail Cable glands Minimum order value for separate orders of spare parts or accessories is 75 €. Cable recommendations for...