Continuous level measuring system NR 3000
10Pages

{{requestButtons}}

Catalog excerpts

Continuous level measuring system NR 3000 - 1

Continuous level measuring system NR 3000 Selection list Page Overview 2 ------------------------------------------------------------------------------------------------------------------Specification 3 ------------------------------------------------------------------------------------------------------------------NR 3100 4 ------------------------------------------------------------------------------------------------------------------Accessories 6 ------------------------------------------------------------------------------------------------------------------Dimensions 7 ------------------------------------------------------------------------------------------------------------------Electrical installation 9 ------------------------------------------------------------------------------------------------------------------Spare parts 10 Subject to change. All dimensions in mm (inches). By publishing this selection list all other lists become invalid. All prices in Euro (€) or USD ($), excluding VAT. We assume no liability for typing errors. All EURO prices are EXW Betzigau, all USD prices are EXW Memphis, excluding packaging costs. Valid: From 01.01.2022 until 31.12.2022, unless otherwise agreed. Different variations to those specified are possible. Please contact our technical consultants.

Open the catalog to page 1
Continuous level measuring system NR 3000 - 2

Continuous level measuring system NR 3000 Selection list Overview Features Continuous level measurement of solids and liquids applications with 78 GHz FMCW radar Measurement range • Up to 100 m (329 ft) Mechanic • Lens antenna and flange for quick and easy positioning • Stainless steel housing • Plane flanges and Easy aimer flanges Service • Plug and play system, simple installation and commissioning • Configuration with only 6 parameters on display with push buttons • Alternative configuration via HART possible. Approvals • Approval for use in Hazardous Locations (gas and dust) •...

Open the catalog to page 2
Continuous level measuring system NR 3000 - 3

Continuous level measuring system NR 3000 Selection list Specification Specification Process Beam angle Update time Maximum 10 seconds (Response Rate (2.4.1.) set to FAST) Dielectric constant of material measured Ingress protection 316L/ 1.4404 Lid with window (window material polycarbonate) Lens antenna Material: 40 m version: PEI 100 m version: PEEK Female 1/8" NPT fitting Non return valve for 6 mm tube (optional) Power supply/ Communication 4-20 mA loop power Nominal 24V DC (16.5 .. 30 V DC) Protocol HART, Version 6.0 Plug on display (inside housing) Approvals Process overpressure 400 mm...

Open the catalog to page 3
Continuous level measuring system NR 3000 - 4

Continuous level measuring system NR 3000 Selection list Version with plane flange Version with Easy Aimer flange Fig. states plane flange 100 mm/ 4" Fig. states Easy Aimer flange 100 mm/ 4" Plug on Display With push buttons. For programing of the unit. Once programmed, the Plug on Display can be removed if desired and used to copy parameters to multiple units.

Open the catalog to page 4
Continuous level measuring system NR 3000 - 5

Continuous level measuring system NR 3000 Selection list Certificate (1) (detailed Ex-markings: see page 8) 0 CE/ TR-CU FM/ CSA F ATEX/ IEC-Ex ATEX/ IEC-Ex FM/ CSA FM/ CSA TR-CU TR-CU Protection method General purpose Dust Ignition Proof Non-sparking/ Energy Limited Dust Ignition Proof Non-incendive Dust Ignition Proof Non-sparking Process temperature Process pressure Electronic module Process connection (3) Flange 80 mm/ 3" plane Flange 80 mm/ 3" plane Flange 80 mm/ 3" Easy Aimer Flange 100 mm/ 4" plane Flange 100 mm/ 4" plane Flange 100 mm/ 4" Easy Aimer Flange 150 mm/ 6" plane Flange 150...

Open the catalog to page 5
Continuous level measuring system NR 3000 - 6

Continuous level measuring system NR 3000 Selection list Accessories Accessories Minimum order value for separate orders of spare parts or accessories is 75 €. For purge inlet. Stainless steel. Connection of 6mm tube diameter. Opens at ca. 0.5 bar (7.25 psi). zu400530 HART Modem USB HART Interface to connect a PC with the NR 3000 for commissioning and servicing. Protector plate for sensor lense Protection of the lense against condensation, dust, buildup, crystallisation. Mounting between unit flange and silo flange. Material PTFE. Available up to 100°C, 0,5bar, 40m range. Not in combination...

Open the catalog to page 6
Continuous level measuring system NR 3000 - 7

Continuous level measuring system NR 3000 Selection list Dimensions Plane flange version Lid lock Grounding lug Purge inlet Process connection flange Sensor reference point Bolt holes: see next page Easy Aimer flange version 80 mm/ 3" Sensor reference point Bolt holes: see next page Easy Aimer flange version 100 mm/ 4" 150 mm/ 6" Sensor reference point Bolt holes: see next page

Open the catalog to page 7
Continuous level measuring system NR 3000 - 8

Continuous level measuring system NR 3000 Selection list Dimensions Flanges Universal flange (plane flange and Easy aimer flange) mates with bolt hole pattern of: EN 1092-1 (PN16) ASME B16.5 (150 lb) JIS 2220 (10K) Max. circle diameter Min. circle diameter Bolt hole diameter Pipe size Bolt hole diameter Number of bolt holes Detailed Ex-markings General purpose F ATEX IEC-Ex ATEX IEC-Ex FM/ CSA FM/ CSA TR-CU TR-CU ATEX II 1D, 1/2D, 2D Ex ta IIIC T139°C Da IP68 Ex ta IIIC T139°C Da IP68 ATEX II 3G Ex nA II T4 Gc, Ex nL IIC T4 Gc Ex nA II T4 Gc, Ex nL IIC T4 Gc DIP Class II, Div.1, Gr. E, F,...

Open the catalog to page 8
Continuous level measuring system NR 3000 - 9

Continuous level measuring system NR 3000 Selection list The terminals are located below the display. To connect the unit, remove the display by gently turning the display a quarter turn counter-clockwise until it is free. Use twisted pair cable: 0.34 mm² to 2.5 mm² (AWG 22 to 14) Connect cable shield to ground terminal . Typical PLC/mA configuration with HART: • Depending on the system design, the power supply may be separate from the PLC, or integral to it. • HART resistance (total loop resistance, that is, cable resistance plus 250 Ohm (external resistor) must be less than 550 Ohm @24V...

Open the catalog to page 9
Continuous level measuring system NR 3000 - 10

Continuous level measuring system NR 3000 Selection list Spare parts Minimum order value for separate orders of spare parts or accessories is 75 €. Spare part Article number Electronic module, measurement range max. 40 m Electronic module, measurement range max. 100 m Lid with glas window Sun protection cover (stainless steel 1.4301/ 304) Wrench for 100 mm/ 4" and 150 mm/ 6" Easy Aimer Allen key 3 mm for 100 mm/ 4" and 150 mm/ 6" Easy Aimer Diverse Non return valve Lid with glass window Allen key for Easy Aimer Sealing for Easy Aimer Wrench for Easy Aimer

Open the catalog to page 10

All UWT GmbH catalogs and technical brochures

  1. DK value

    8 Pages