Group: UWT-Group

Catalog excerpts

Two-wire: 4 … 20 mA/HART Series NR 3100 Technical information / Instruction manual Contents page About this document Product description Technical data Setup - the most important steps Connecting to power supply Access protection, IT security Set up with the display and adjustment module Menu overview Set up with other systems Diagnosis, asset management and service
Open the catalog to page 1
Two-wire: 4 … 20 mA/HART Series NR 3100 Technical information / Instruction manual Contents Certificates, approvals and certifications
Open the catalog to page 2
Two-wire: 4 … 20 mA/HART Series NR 3100 Technical information / Instruction manual About this document Function This instruction provides all the information you need for mounting, connection and setup as well as important instructions for maintenance, fault rectification, safety and the exchange of parts. Please read this information before putting the instrument into operation and keep this manual accessible in the immediate vicinity of the device. Target group This instruction manual is directed to trained personnel. The contents of this manual must be made available to the qualified...
Open the catalog to page 3
Two-wire: 4 … 20 mA/HART Series NR 3100 Technical information / Instruction manual For your safety Authorised personnel All operations described in this documentation must be carried out only by trained and authorized personnel. During work on and with the device, the required personal protective equipment must always be worn. Appropriate use NivoRadar 3100 is a sensor for continuous level measurement. You can find detailed information about the area of application in chapter "Product description". Operational reliability is ensured only if the instrument is properly used according to the...
Open the catalog to page 4
Two-wire: 4 … 20 mA/HART Series NR 3100 Technical information / Instruction manual For your safety the measuring frequency can be found in chapter "Technical data". Mode of operation - Radar signal Country or region specific settings for the radar signals are determined via the mode. The operating mode must be set in the operating menu via the respective operating tool at the beginning of the setup. Caution: Operating the device without selecting the relevant mode constitutes a violation of the regulations of the radio approvals of the respective country or region. Installation and...
Open the catalog to page 5
Two-wire: 4 … 20 mA/HART Series NR 3100 Technical information / Instruction manual Product description Configuration Scope of delivery The scope of delivery encompasses: Radar sensor, possibly with accessories Information sheet "Access protection" (with SIL, IT security, Bluetooth versions) with: –– Bluetooth access code –– Emergency Bluetooth unlock code –– Device code –– Emergency device code Information sheet "PINs and Codes" (with SIL, IT security, Bluetooth versions) with: –– Bluetooth access code –– Device code Documentation –– Quick setup guide –– Instructions for optional instrument...
Open the catalog to page 6
Two-wire: 4 … 20 mA/HART Series NR 3100 Technical information / Instruction manual Product description Constituent parts Type label Radar antenna Process fitting Process seal Electronics housing Housing cover with optional display and adjustment module Ventilation The type label contains the most important data for identification and use of the instrument: Instrument type Information about approvals Configuration information Technical data Serial number of the instrument QR code for device identification Numerical code for Bluetooth access (optional) Manufacturer information Documents and...
Open the catalog to page 7
Two-wire: 4 … 20 mA/HART Series NR 3100 Technical information / Instruction manual Product description modified frequency. The frequency change is proportional to the distance and is converted into the level. Adjustment Local adjustment On-site adjustment of the device is carried out via the integrated display and adjustment unit. Note: The housing with display and adjustment unit can be rotated by 360° for optimum readability and operability. Wireless adjustment Devices with integrated Bluetooth module can be adjusted wirelessly via standard adjustment tools: Smartphone/tablet (iOS or...
Open the catalog to page 8
Two-wire: 4 … 20 mA/HART Series NR 3100 Technical information / Instruction manual Product description Transport Transport must be carried out in due consideration of the notes on the transport packaging. Nonobservance of these instructions can cause damage to the device. Transport inspection The delivery must be checked for completeness and possible transit damage immediately at receipt. Ascertained transit damage or concealed defects must be appropriately dealt with. Up to the time of installation, the packages must be left closed and stored according to the orientation and storage...
Open the catalog to page 9
Two-wire: 4 … 20 mA/HART Series NR 3100 Technical information / Instruction manual Technical data Technical data Note for approved instruments The technical data in the respective safety instructions which are included in delivery are valid for approved instruments (e.g. with Ex approval). These data can differ from the data listed herein, for example regarding the process conditions or the voltage supply. All approval documents can be downloaded from our homepage. Materials and weights Materials, wetted parts Plastic horn antenna ƲƲ Adapter flange ƲƲ Seal, adapter flange Rinsing air...
Open the catalog to page 10
Two-wire: 4 … 20 mA/HART Series NR 3100 Technical information / Instruction manual Technical data Weights ƲƲ Instrument (depending on housing, process fitting and antenna) Torques Max. torque ƲƲ Mounting screws, mounting strap 4 Nm (2.950 lbf ft) on sensor housing ƲƲ Flange screws, compression flange DN 80 ƲƲ Terminal screws, adapter flange - 2.5 Nm (1.844 lbf ft) antenna ƲƲ Flange screws, adapter flange DN 100 Max. torque for NPT cable glands and Conduit tubes ƲƲ Aluminium/Stainless steel housing Torque housing locking ƲƲ Recommended torque locking screw ƲƲ Max. torque locking screw Input...
Open the catalog to page 11All UWT GmbH catalogs and technical brochures
-
NivoRadar ® 7000
2 Pages
-
NivoRadar® NR 3000
2 Pages
-
NivoRadar® NR 8000 en
2 Pages
-
NivoTec® Visualisation
2 Pages
-
Product-Overview UWT 2024-12
36 Pages
-
Product Matrix en
2 Pages
-
Level limit switch RFnivo® 3000
44 Pages
-
Level limit switch RFnivo® 8000
39 Pages
-
Radar Flyer New 2024
2 Pages
-
Solids - Liquids at a glance
2 Pages
-
Highlight NivoRadar® 4000 en
1 Pages
-
NivoCapa® NC 8000
2 Pages
-
Vibranivo® VN 4000
2 Pages
-
Vibranivo® VN 2000 / VN 6000
2 Pages
-
Vibranivo® VN 1000 / VN 5000
2 Pages
-
RFnivo® 8000 Product Leaflet
2 Pages
-
Rotonivo® RN 4000
2 Pages
-
Rotonivo® RN 3000 / 6000
2 Pages
-
NivoGuide® NG 3000
2 Pages
-
NivoBob® NB 4000
2 Pages
-
NivoBob® NB 3000
2 Pages
-
Capanivo® CN 4000
2 Pages
-
Capanivo® CN 8000
2 Pages
-
Solutions for the Grain industry
26 Pages
-
Vibrasil®70/90 Level switch
2 Pages
-
Solutions for the Power Industry
28 Pages
-
Solutions for the Steel Industry
26 Pages
-
DK value
8 Pages
Archived catalogs
-
Flyer Solids / Liquids
2 Pages