Product catalog summary
Safety Notes and Technical Support
Installation, maintenance, and commissioning of the CN 4000 series should be performed by qualified personnel. The manual outlines safety symbols indicating potential risks such as electric shock or material damage. For technical support, contact UWT GmbH or your local supplier.
Introduction
The CN 4000 series is a capacitive level limit switch used for monitoring levels in containers and silos across various industries. It detects capacitance around its probe and is insensitive to material buildup, allowing for factory precalibration.
Technical Data
Electrical Data: The device supports various connection types and power supplies, with adjustable signal delays and sensitivity, including safety operations and overvoltage protection.
Mechanical Data: The housing is available in plastics or aluminium, designed for IP66 protection, and can handle specific mechanical torques and pressures.
Environmental Conditions: Suitable for a range of temperatures and humidity, with specific storage and transport conditions.
Approvals
The CN 4000 series complies with international standards for general and hazardous locations, including ATEX, UKEX, IEC-Ex, and is RoHS compliant.
Options and Accessories
Accessories include weather-protection covers, hexagon nuts, sliding sleeves, signal lamps, and various plugs and adapters to enhance functionality and adaptability.
Mounting
Proper installation is crucial for maintaining process pressure and chemical resistance. The mounting torque should not exceed specified limits, and the device should be sealed properly to prevent leaks.
Mounting Instructions
The manual outlines various mounting positions for full, demand, or empty detectors, emphasizing slight incline mounting to facilitate material flow.
Electrical Installation
Key points include protective earthing, adherence to local installation regulations, and the use of appropriate fuses and RCCB protection.
Safety Instructions
Grounding is essential to prevent static charging, with guidelines for external equipotential bonding and additional safety instructions for hazardous locations.
Settings and Signal Output
The manual details factory settings for sensitivity and signal output logic, with options for adjustment based on application needs.
Maintenance
Instructions for changing the electronic board and guidelines for frequent checks and cleaning are provided to ensure safety and functionality.
Hazardous Locations
Notes on zone classification and marking for devices with Ex approval are included, with guidelines for installation to avoid electrostatic charges.
Specifications
  • Equipment Protection Levels (EPL): Suitable for Zone 21 (EPL Db, Category 2D) and Zone 20 (EPL Da, Category 1D).
  • Temperature Ratings: Maximum surface temperature is determined by the hottest temperature during malfunction.
  • Ambient and Process Temperatures: Maximum ambient temperature is 60°C (140°F), with process temperatures ranging from 120°C (248°F) to 180°C (356°F) depending on the version.
Procedures
  • Temperature Marking: Refers to the instruction manual for detailed ratings.
  • Derating: Users must observe derating as specified in the manual.
Disposal
The product is made from recyclable materials, and recycling should be conducted by a specialized company.
Notes for Use in Hazardous Locations
Ensure compliance with specified temperature limits to maintain safety and functionality in hazardous environments.
See more

Catalog excerpts

Capanivo® CN 4000-1

Level limit switch Series CN 4000 Technical Information / Instruction manual 2 Page Safety notes/ Technical support 2 ----------------------------------------------------------------------------------------------------- Introduction 3 ----------------------------------------------------------------------------------------------------Technical data 4 Options/ accessories 10 ----------------------------------------------------------------------------------------------------Mounting 11 ----------------------------------------------------------------------------------------------------Electrical installation 13 ----------------------------------------------------------------------------------------------------Settings 17 ----------------------------------------------------------------------------------------------------Signal output logic 18 ----------------------------------------------------------------------------------------------------- Maintenance 19 ----------------------------------------------------------------------------------------------------Notes for use in Hazardous Locations 10 Subject to technical change. We assume no liability for typing errors. Different variations than specified are possible. Please contact our technical consultants.

 Open the catalog to page 1
Capanivo® CN 4000-2

Level limit switch Series CN 4000 Technical Information / Instruction manual Safety notes / Technical support Installation, maintenance and commissioning may be accomplished only by qualified technical personnel. The product must be used only in the manner outlined in this instruction manual. 3 Special attention must be paid to warnings and notes as follows: WARNING Relates to a caution symbol on the product: A failure to observe the necessary precautions can result in death, serious injury and/ or considerable material damage. Relates to a caution symbol on the product: Risk of electric shock...

 Open the catalog to page 2
Capanivo® CN 4000-3

Level limit switch Series CN 4000 Technical Information / Instruction manual Capacitive level limit switch for level monitoring in all types of containers and silos. The Capanivo detects the capacitance around its probe. Due to the active shield technology it has an increased insensitivity to material buildup on the probe. It can be used with powdery and granulated bulk materials with a dielectric constant of min. 1.6 The measurement is nearly independent from the influence of the silo wall. Therefore factory provided precalibration allows measurement of most applications without calibration...

 Open the catalog to page 3
Capanivo® CN 4000-4

Level limit switch Series CN 4000 Technical Information / Instruction manual Technical data Housing versions

 Open the catalog to page 4
Capanivo® CN 4000-5

Level limit switch Series CN 4000 Technical Information / Instruction manual Technical data Electrical data Connection terminals Cable entry M20 x 1.5 screwed cable gland NPT ½“ or NPT ¾” conduit connection Clamping range (diameter) of the factory provided cable glands: M20 x 1.5: 6 .. 12 mm (0.24 .. 0.47"") Signal delay Sensor free -> covered Sensor covered -> free Safety operation (FSL,FSH) Switchable for minimum or maximum safety Overvoltage category Pollution degree Relay SPDT Relay DPDT Universal voltage Power supply Max. ripple of power supply Installed load Signal output Floating relay...

 Open the catalog to page 5
Capanivo® CN 4000-6

Level limit switch Series CN 4000 Technical Information / Instruction manual Technical data Mechanical data Housing Seal between housing and lid: NBR Seal between housing and process connection: NBR Nameplate: polyester film Plastics PA6 GF, RAL 5010 gentian blue or aluminium, powder coated, RAL 5010 gentian blue IP66 * (EN 60529) * For version with plug the type of protection can be lower (see option plug/ page 10). Process connection and extension CN 4020 version 120°C: Material process connection/ probe: Thread: Adapter (optional): Plastics PPS (glass fibre reinforced) (1), FDA listed (2)...

 Open the catalog to page 6
Capanivo® CN 4000-7

Level limit switch Series CN 4000 Technical Information / Instruction manual Technical data Operating conditions Ambient and process temperature Version with Ex-approval 6 Version with Ex-approval Version with Ex-approval

 Open the catalog to page 7
Capanivo® CN 4000-8

Level limit switch Series CN 4000 Technical Information / Instruction manual Technical data Max. permitted mechanical torque Recommended protection in case of high material load: mounting of a protective angle above the probe Features of bulk material Min. DK: 1.6 (dielectric constant, see external DK tables) Max. grain size: ca. 30 mm Switching point Material with high DK value -> the signal output switches when the probe is covered a few mm Material with low DK value -> the signal output switches, when the probe is covered a few cm Relative Humidity Expected product lifetime Following parameters...

 Open the catalog to page 8
Capanivo® CN 4000-9

Level limit switch Series CN 4000 Technical Information / Instruction manual General Purpose (Ordinary Locations) Hazardous Locations * ATEX UKEX IEC-Ex TR-CU CCC II 1/2D Ex ta/tb IIIC T! Da/Db II 1/2D Ex ta/tb IIIC T! Da/Db Ex ta/tb IIIC T! Da/Db Ex ta/tb IIIC T120°C Da/Db X Ex ta/tb IIIC T! Da/Db ATEX UKEX IEC-Ex TR-CU CCC II 1/2D Ex ta/tb IIIC T! Da/Db II 1/2D Ex ta/tb IIIC T! Da/Db Ex ta/tb IIIC T! Da/Db Ex ta/tb IIIC T120°C…T180°C Da/Db X Ex ta/tb IIIC T! Da/Db ATEX UKEX IEC-Ex TR-CU CCC II 1/2D Ex ta/tb IIIC T! Da/Db II 1/2D Ex ta/tb IIIC T! Da/Db Ex ta/tb IIIC T! Da/Db Ex ta/tb IIIC T120°C...

 Open the catalog to page 9
Capanivo® CN 4000-10

Level limit switch Series CN 4000 Technical Information / Instruction manual Options / Accessories When the measuring device is used outdoor, the use of the weather-protection-cover is recommended. It protects the device from all atmospheric influences such as: • rain water • condensation of water • excessively high temperatures due to insulation • excessively low temperatures in winter Material: PE, weathering and temperature stable For use in Hazardous Locations: only permitted for Zone 22. For mounting on a wall without a socket. Material: Aluminium or 1.4305 (303) Sliding sleeve Signal lamp...

 Open the catalog to page 10
Capanivo® CN 4000-11

Level limit switch Series CN 4000 Technical Information / Instruction manual General Safety Instructions Process pressure Improper installation may result in loss of process pressure. Chemical resistance against the medium Materials of construction are chosen based on their chemical compatibility (or inertness) for general purposes. For exposure to specific environments, check with chemical compatibility charts before installing. Fastening of the threaded process connection Mounting torque for the thread may not exceed 40 Nm (metal thread)/ 20 Nm (plastic thread). Use a open-end wrench. Do not...

 Open the catalog to page 11

All UWT GmbH catalogs and technical brochures

  1. DK value

    8  Pages

  2. Mononivo® 4000

    25  Pages

  3. NivoBob® 3000

    41  Pages

  4. NivoCapa® 8000

    27  Pages

  5. NivoBob® 4000

    31  Pages

  6. RFnivo® 3000

    44  Pages

  7. RFnivo® 8000

    39  Pages

  8. Rotonivo® 4000

    21  Pages

  9. RFnivo® 8000

    2  Pages

  10. RFnivo® 3000

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.