1. Catalogs
  2. UNIVERSAL TECHNIC
  3. Current Probe S.UE 1000A / 1V

Current Probe S.UE 1000A / 1V

Current Probe S.UE 1000A / 1V

Current Probe S.UE 1000A / 1V

Product catalog summary
Electrical Characteristics
The S.UE 1000A / 1V current probe is designed for non-intrusive AC current measurement with a current range of 1000 ARMS and a continuous measuring range from 1 A to 1200 ARMS. It has an output sensitivity of 1 mV/A and requires a load impedance of ≥ 100 kOhm. The probe is sensitive to conductor position at 0.5% at 50Hz and has an error due to adjacent conductors of ≤ 1mA/A at 50 Hz. It operates over a frequency range of 30 Hz to 10 kHz with a temperature coefficient of 0.01%/°C. The working voltage is 600 V ACRMS or DC.
Accuracy
The accuracy varies with the primary current: ±3%+0.1mv for 1 to 10 A, ±1.5% for 10 to 100 A, and ±0.5% for 100 to 1200 A. Phase shift is specified as 0.5° for 10 to 100 A and 0.3° for 100 to 1200 A.
General Characteristics
The probe can accommodate a maximum conductor size of 50 mm in diameter and connects via 4mm safety sockets. It operates in temperatures ranging from -10 to +55 °C and can be stored between -40 to +70 °C. The operating humidity is 15% to 85% non-condensing, and the probe weighs 620 g.
Application
The S.UE 1000A / 1V is suitable for use with multimeters, recorders, power analyzers, and safety testers, utilizing the latest transformer technology for accurate current measurement from 1A to 1200A over a frequency range of 30Hz to 10kHz.
Reference Conditions
The reference conditions include a temperature range of +18°C to 26°C, humidity of 20 to 75% RH, sinusoidal current between 48 to 65Hz, and a distortion factor of less than 1%. The probe should be used with a load impedance of ≥1MΩ and <100pF for voltage output.
Safety Standards
The probe complies with IEC61010-1: 2010, IEC61010-2-032: 2012, and IEC61010-2-031: 2008 standards. It is rated for 600 VRMS, Category III, Pollution Degree 2, and is limited to use on uninsulated conductors up to 600 V ACRMS or DC and frequencies below 1 kHz.
EMC Standards
The probe meets the EN 61326:1998 standard.
See more

Catalog excerpts

Current Probe S.UE 1000A / 1V-1

UNiuersal TeehNic Current Probe S.UE 1000A / 1V The S.UE 1000A / 1V current probe has been designed for use with multimeters, recorders, power analysers, safety testers etc. for accurate non intrusive measurement of AC current. Using the latest transformer technology, the S.UE 1000A / 1V can measure currents from 1A to 1200A over a frequency range of 30Hz to 10kHz. 50 mm diameter 4mm safety sockets -10 to +55 °C -40 to +70 °C 15% to 85% (non condensing) 620 g Website : www.universal-technic.com Email : [email protected]

 Open the catalog to page 1
Current Probe S.UE 1000A / 1V-2

Reference conditions: Temperature : +18°C to 26 °C, humidity: 20 to 75% RH, sinusoidal current: 48 to 65Hz, distortion factor: < 1%, DC current: none, DC magnetic field: 40 A/m earth’s magnetic field, alternating magnetic field: none, proximity of external conductor: none, primary conductor: centred in the aperture, load impedance: >1 Mfl, <100pF for voltage output. Safety Standards IEC61010-1: 2010 IEC61010-2-032: 2012 IEC61010-2-031: 2008 600 Vrms, Category III, Pollution Degree 2 Use of the probe on uninsulated conductors is limited to 600 V ACrms or DC and frequencies below 1 kHz. Website...

 Open the catalog to page 2

All UNIVERSAL TECHNIC catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.