The M3.UB 10A / 1V current probe is designed for accurate, non-intrusive AC current measurement, compatible with multimeters, recorders, and safety testers. It utilizes advanced transformer technology to measure currents from 10mA to 10A across a frequency range of 30Hz to 10kHz. Its compact design allows for easy access in tight spaces.
Electrical Characteristics
  • Current Range: 10 A ACRMS
  • Measuring Range: 10mA to 10ARMS
  • Output Sensitivity: 100mV / A
  • Load Impedance: > 1 MOhm
  • Conductor Position Sensitivity: < 0.5% @ 50/60Hz
  • Frequency Range: 30 Hz to 10 kHz
  • Temperature Coefficient: 0.015% / °C
  • Working Voltage: 600 V ACRMS or DC
Accuracy
  • Primary Current: 10mA to 50mA (5% accuracy), 50mA to 100mA (2% accuracy), 100mA to 10A (1% accuracy)
  • Phase Shift: Not specified for 10mA to 50mA, 5° for 50mA to 100mA, 3° for 100mA to 10A
General Characteristics
  • Maximum Conductor Size: 15 mm diameter, bus bar 15 x 17mm
  • Output Connection: Safety sockets 4mm
  • Operating Temperature Range: -10 to +55 °C
  • Storage Temperature Range: -20 to +70 °C
  • Operating Humidity: 15% to 85% (non-condensing)
  • Weight: 165 g
Reference Conditions
  • Temperature: +18°C to 26 °C
  • Humidity: 20 to 75% RH
  • Sinusoidal Current: 48 to 65Hz
  • Distortion Factor: < 1%
  • DC Magnetic Field: 40 A/m earth’s magnetic field
  • Load Impedance: ≥1MΩ, <100pF for voltage output
Safety Standards
  • IEC61010-1:2010
  • IEC61010-2-032:2012
  • IEC61010-2-031:2008
  • 600 VRMS, Category III, Pollution Degree 2
  • Use on uninsulated conductors limited to 600 V ACRMS or DC and frequencies below 1 kHz
EMC Standards
  • EN 61326:1998
See more

Catalog excerpts

Current probe M3.UB 10A / 1V-1

Universal Technic Current probe M3.UB 10A / 1V The M3.UB 10A / 1V current probe has been designed for use with multimeters, recorders, safety testers etc. for accurate non intrusive measurement of AC current. Using the latest transformer technology, the M3.UB 10A / 1V can measure currents from 10mA to 10A over a frequency range of 30Hz to 10kHz. The very small head facilitates the insertion of the probe in places where ease of access is of crucial importance. Accuracy Primary Current Accuracy (of rdg) Phase shift (typ)

 Open the catalog to page 1
Current probe M3.UB 10A / 1V-2

Reference conditions: Temperature : +18°C to 26 °C, humidity: 20 to 75% RH, sinusoidal current: 48 to 65Hz, distortion factor: < 1%, DC current: none, DC magnetic field: 40 A/m earth’s magnetic field, alternative magnetic field: none, proximity of external conductor: none, primary conductor: centred in the aperture, load impedance: ≥1MΩ, <100pF for voltage output. Safety Standards IEC61010-1:2010 IEC61010-2-032:2012 IEC61010-2-031:2008 600 VRMS, Category III, Pollution Degree 2 Use of the probe on uninsulated conductors is limited to 600 V ACRMS or DC and frequencies below 1 kHz. Website : www.universal-technic.com...

 Open the catalog to page 2

All UNIVERSAL TECHNIC catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.