Current Probe H16 1000A / 5A - 1

1000 Arms 1 A to 1200 Arms 5 mA / A < 1 Ohm 0.5% @ 50Hz < 5mA / A @ 50 Hz 2.5° 30 Hz to 10 kHz 0.01% / °C 600 V ACrms or DC Universal Technic Current Probe H16 1000A / 5A The H16 1000A / 5A current probe has been designed for use with multimeters, recorders, power analysers, safety testers etc. for accurate non intrusive measurement of AC current. Using the latest transformer technology, the H16 1000A / 5A can measure currents from 1 A to 1200 A over a frequency range of 30Hz to 10kHz. Working Voltage (see Safety Standards section) Website : www.universal-technic.com Email : lut@fluke.com

Open the catalog to page 1
Current Probe H16 1000A / 5A - 2

Reference conditions: Temperature : +18°C to 26 °C, humidity: 20 to 75% RH, sinusoidal current: 48 to 65Hz, distortion factor: < 1%, DC current: none, DC magnetic field: 40 A/m earth’s magnetic field, alternating magnetic field: none, proximity of external conductor: none, primary conductor: centred in the aperture, load impedance: ≤1Ω for current output. Safety Standards IEC61010-1: 2010 IEC61010-2-032: 2012 IEC61010-2-031: 2008 600 VRMS, Category III, Pollution Degree 2 Use of the probe on uninsulated conductors is limited to 600 V ACRMS or DC and frequencies below 1 kHz. Douilles de...