video corpo
cad

Serie UKTM

Serie UKTM

Serie UKTM

Product catalog summary
Overview
The document details the UKTM series oil/water heat exchangers, highlighting their compact design, high performance, and cost-effectiveness for industrial applications.
Specifications
The UKTM series includes over 30 basic units in double and four-pass versions, with cooling surfaces ranging from 0.73 m² to 29 m². They feature aluminum fins and copper or copper-nickel tubes, supporting oil flow rates up to 650 l/min and maximum pressures of 35 bar for oil and 16 bar for water.
Product Features
  • Large-bore oil connections for reduced flow resistance.
  • Removable end caps for easy maintenance.
  • Flanges for 90° rotation of the exchanger.
  • Optional patented internal bypass check valve.
  • High-quality materials and a full range of accessories.
  • Available in a sea water version.
Performance Data
Performance is based on a water inlet temperature of 25°C and an oil outlet temperature of 50°C, with an oil viscosity of 20.6 cSt. A correction factor is applicable for different viscosities.
Example Calculation
An example calculation is provided to determine effective heat dissipation using parameters like heat to be dissipated, oil flow, and temperatures, involving viscosity correction factors and performance diagrams.
Dimensions
Detailed dimensions for various UKTM models are provided, covering both 2-way and 4-way configurations.
Ordering Information
An ordering code specifies the configuration and materials, including options for copper or copper/nickel tubes and sea water compatibility.
Technical Data
Maximum operating pressure is 35 bar for the shell and 16 bar for the tubes, with a maximum operating temperature of 95°C.
Specifications for Seawater Models
Technical specifications for models like UKTM-500, UKTM-700, UKTM-1000, and UKTM-1200 are provided, with materials including copper and copper-nickel.
Connection Types
Connection types include NPT, SAE, BSPF, and SAE flange, with 2-pass and 4-pass configurations available, except for series 500.
Special Features
Special versions with bypass valves are available, which can be partly or fully opened.
Operational Conditions
Technical data is contingent on specific operational conditions, with deviations requiring contact with Universal Hydraulik. Users should refer to operation manuals and maintenance documentation.
Contact Information
Universal Hydraulik GmbH is the distributor, located at Siemensstr. 33, D-61267 Neu-Anspach, with contact details provided for phone and email.
See more

Catalog excerpts

Serie UKTM-1

advanced quality customized designs made in europe Öl/Wasser-Wärmetauscher Oil/water heat exchangers Echangeur thermique huile/eau Ihr Partner für Kühler und Systeme UKTM Für den Tankeinbau konstruiert Constructed for mounting in tanks Construit pour montage sur tank Die Abbildung zeigt das Tankeinbaugehäuse und den Hochleistungs-Kühlungseinsatz mit Rohrbündel und Kühlrippen. The picture shows the Tank mounting case and the high-performance Cooling tray with tubes and cooling fins. L’image montre l’etui pour montage sur tank et la chambre à refroidissement haute performance avec faisceau tubulaire et nervures de refroidissement.

 Open the catalog to page 1
Serie UKTM-2

Ihr Partner für Kühler und Systeme Produktbeschreibung / Product description / Discription du produit Produktbeschreibung Product description Die UKTM-Serie ist eine konsequente Weiterentwicklung eines Rohrbündel-Wärmetauschers für weite Anwendungsgebiete in der Industrie. Durch die zusätzliche Kühlfläche ist diese Baureihe äußerst effektiv. Dies wird durch Aluminiumlamellen, die über das Rohrbündel geschoben werden und metallisch verbunden sind, realisiert. Die UKTM-Wärmetauscher haben eine Kühlfläche von 0,73 m2 bis 29 m2. Die Serie UKTM setzt sich aus über 30 Grundeinheiten zusammen, die jeweils...

 Open the catalog to page 2
Serie UKTM-3

Ihr Partner für Kühler und Systeme Berechnungsbeispiel / Example calculation / Example de calcul Bei abweichenden Ölaus-, bzw. Wassereintrittstemperaturen und Viskositäten, ist nach den folgenden Berechnungsbeispielen zu verfahren: For different oil outlet temperatures, water inlet temperatures and viscosities, the following calculation must be made: En cas de divergence au niveau de la température de sortie de l’huile ou de la température d’entrée de l’eau et de divergence au niveau de la viscosité, procéder comme le montrent les exemples de calcul suivants: Donné: Temp. de sortie de l’huile...

 Open the catalog to page 3
Serie UKTM-4

Ihr Partner für Kühler und Systeme Kennlinien / Performance Data / Courbes caractéristiques 2 Weg / 2 passes / 2 voies Kühlleistung kW / Cooling performance kW / Puissance de refroidissement en kW siehe Rechenbeispiel see example calculation voie example de calcul Durchfluß l/min / Flow rate l/min / Débit l/min Modell / model / modèle 1 Die Kennlinien in diesem Diagramm sind vom Durchfluß begrenzt und können in Abstimmung mit dem Hersteller überschritten werden. The performance Data shown in the diagram are limited by the flow rate, and may be exceeded after consultation with the manufacturer....

 Open the catalog to page 4
Serie UKTM-5

Ihr Partner für Kühler und Systeme Kennlinien / Performance Data / Courbes caractéristiques Kühlleistung kW / Cooling performance kW / Puissance de refroidissement en kW 4 Wege / 4 pass / 4 voies Durchfluß l/min / Flow rate l/min / Débit l/min Modell / model / modèle 19 Die Kennlinien in diesem Diagramm sind vom Durchfluß begrenzt und können in Abstimmung mit dem Hersteller überschritten werden. The performance Data shown in the diagram are limited by the flow rate, and may be exceeded after consultation with the manufacturer. Les courbes caractéristiques de ce diagramme sont limitées par le...

 Open the catalog to page 5
Serie UKTM-6

Ihr Partner für Kühler und Systeme Abmessungen UKTM / Dimensions UKTM / Dimensions UKTM WASSER EINTRITT - AUSTRITT WATER INLET - OUTLET Abmessungen Flansch / Dimensions flange / Dimensions bride

 Open the catalog to page 6
Serie UKTM-7

Ihr Partner für Kühler und Systeme Geräteabmessungen / Unit Dimensions / Dimensions des appareils 2-Wege / ways / voies Grundmaße / Basic dimensions / Dimensions base * Option: Baugrößen / Unit size / Taille 500 + 700: SAE 1 1/2”; Baugröße / Unit size / Taille 1000: Innengewinde / Thread / Filet * Option: Baugröße / Unit size / Taille 1200: K - R 1”, R 1 1/4”, R 1 1/2”

 Open the catalog to page 7
Serie UKTM-8

advanced quality customized designs made in europe Ihr Partner für Kühler und Systeme Bestellschlüssel / Ordering code / Code de commande UKTM - 1014 - 2 - T - R - CN - W - SW - 01 - S Anschlußtyp Connection type Type de raccordement = NPT SAE = S = M BSPF SAE Flansch / = FM SAE flange S = Sonderausführung Special version Version spéciale Serie 01 Baugröße / Unit size / Taille SW = Seewasser / Sea water / Eau de mer Umlenksegmentabstand / Guide segment setting / Ecart des segmentsdéflecteurs Kühlwasserführung / Cooling water connection system Raccordement eau de refroidissement 2- Weg / 2-pass...

 Open the catalog to page 8

All Universal Hydraulik GmbH catalogs and technical brochures

  1. LKM

    1  Page

  2. LKI/LKI-HYD

    13  Pages

  3. UHD 160

    12  Pages

  4. SSP/ HSSP

    7  Pages

  5. UKC-G

    2  Pages

  6. CKM/FS

    2  Pages

  7. EK/SC UK/UKT

    10  Pages

  8. EKM/SKM

    12  Pages

  9. SCM

    7  Pages

  10. TFS/A

    4  Pages

  11. EK/SC

    10  Pages

  12. LKFM

    1  Page

  13. Serie SCM/FS

    2  Pages

  14. Serie SCM

    7  Pages

  15. Serie UKCG

    2  Pages

  16. SSP series

    4  Pages

  17. Serie WRV

    2  Pages

  18. CK-series

    4  Pages

  19. Serie UKM

    8  Pages

  20. Serie CKMFS

    2  Pages

  21. Serie TL

    4  Pages

  22. Serie TFSA

    4  Pages

  23. Serie PWT

    2  Pages

  24. Serie LKM

    12  Pages

  25. Serie LKI

    12  Pages

  26. Serie LKI-HYD

    8  Pages

  27. Serie EKM/SKM

    10  Pages

  28. Serie EDH

    8  Pages

  29. Serie ECM

    8  Pages

  30. Serie CKM

    8  Pages

  31. PTÖK series

    6  Pages

Archived catalogs

  1. Serie AM

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.