The document details the technical specifications and features of the AM series oil/water heat exchangers, designed for industrial applications. These exchangers are compact and high-performance, available in various configurations and materials, including options for sea water and stainless steel versions.
Specifications
The AM series comprises 110 standardized models with heat exchange surfaces ranging from 0.11 m² to 11.45 m². The models are based on 18 basic units, available in narrow or wide guide plate settings, and in 1-way, 2-way, and 4-way configurations.
Product Features
  • Rigid pipe bundle construction
  • Large-bore oil connections for minimal flow resistance
  • Heat dissipation capacity up to 330 kW
  • Oil flow rates up to 760 l/min
  • Removable end caps for easy cleaning
  • High-quality materials with pressure ratings of 20 bar on the housing side and 10 bar on the pipe side
  • Full range of accessories available
  • Selectable guide plate spacing
Options
  • Sea water compatible version
  • Stainless steel version
  • U-tube with drawable tube bundle
Materials
The heat exchangers are constructed using materials such as brass, stainless steel, copper, and copper-nickel for various components like housing, end plates, and pipes.
Calculation Example
An example calculation is provided to determine effective heat dissipation based on parameters like oil flow, oil outlet temperature, and water inlet temperature. It involves calculating the viscosity correction factor and using performance diagrams to select the appropriate cooler model.
Performance Data
Performance data is based on a water inlet temperature of 25°C, an oil/water ratio of 2:1, and an average oil viscosity of 22 cSt. The document includes performance curves and correction factors for different viscosities.
Maximum Operating Conditions
The maximum permissible operating pressure is 15 bar around the pipes and 14 bar through the pipes, with test over-pressures of 25 bar and 20 bar, respectively. Maximum operating temperatures are 95°C around the pipes and 90°C through the pipes.
Caution
Incorrect installation can cause damage. For sea water versions, zinc anodes should be used on the water side to prevent corrosion.
Specifications
The document lists various models of cooling units with specific dimensions and specifications, including models like AM-1024-F, AM-1036-F, AM-1048-F, each with parameters such as C, E, G, R, and T values.
Ordering Code
The ordering code is structured as SS - U - AM - 1014 - A - 6 - F - CU - B, where each segment represents a specific product attribute, such as unit size, pipe diameter, version, guide segment setting, connection type, and material.
Materials and Construction
Materials used include Copper-Nickel, Copper, Stainless Steel, and Admiralty Brass. Complete coolers are available in stainless steel and U-tube configurations.
Contact Information
Universal Hydraulik GmbH is responsible for sales and distribution, with contact details provided for further inquiries.
Technical Notes
The technical data is contingent on specific operational conditions. For different conditions, it is advised to contact Universal Hydraulik. The document notes that technical modifications are reserved and refers to operation manuals and maintenance documentation for further guidance.
See more

Catalog excerpts

Serie AM-1

advanced quality customized designs made in europe Öl/Wasser-Wärmetauscher Oil/water heat exchangers Echangeur thermique huile/eau Ihr Partner für Kühler und Systeme AM Für den industriellen Einsatz For industrial use A usage industriel I Optional als U-Rohr (ziehbares Rohrbündel) I Option: U-tube (drawable tube bundle) I Option: U-tube (faisceau tubulaire tractable) I Sea water version I Version eau de mer I Stainless steel version I Version acier inox

 Open the catalog to page 1
Serie AM-2

Ihr Partner für Kühler und Systeme Produktbeschreibung / Product description / Discription du produit Produktbeschreibung Product description Der AM ist ein kompakter Wärmeaustauscher mit festem Rohrbündel, der in 110 sinnvoll gestaffelten Bautypen von 0,11 m2 bis 11,45 m2 Wärmeaustauschfläche genormt wurde. Die Bautypen setzen sich aus 18 Grundeinheiten zusammen, die jeweils in zwei Ausführungen ( enger-/ weiter Umlenkblechabstand) unterteilt werden, sowie in jeweils eine 1-Weg-, und, bis auf Bautyp AM - 408 - O, 2-Wege- und 4-Wege-Ausführung. The AM is a series of compact heatexchangers with...

 Open the catalog to page 2
Serie AM-3

Berechnungsbeispiel / Example calculation / Example de calcul Bei abweichenden Ölaus-, bzw. Wassereintrittstemperaturen und Viskositäten, ist nach den folgenden Berechnungsbeispielen zu verfahren: For different oil outlet temperatures, water inlet temperatures and viscosities, the following calculation must be made: En cas de divergence au niveau de la température de sortie de l’huile ou de la température d’entrée de l’eau et de divergence au niveau de la viscosité, procéder comme le montrent les exemples de calcul suivants: Donné: Temp. de sortie de l’huile (t huile sor.) = 45°C Water inlet...

 Open the catalog to page 3
Serie AM-4

Ihr Partner für Kühler und Systeme Kennlinien/Performance Data/Courbes caractéristiques Kühlleistung kW / Cooling performance kW / Puissance de refroidissement en kW siehe Rechenbeispiel Druckverlust Pressure loss Perte de pression Kurven basieren auf der Ölsorte ISO-VG-32 Öl/Wasser Verhältnis 2:1 Performance Data based on oil to ISO-VG-32 Oil/water ratio 2:1 Ces courbes sont basées sur l'huile ISO-VG-32 Rapport huile/eau 2:1 Durchfluß l/min / Throughput l/min / Débit l/min

 Open the catalog to page 4
Serie AM-5

Ihr Partner für Kühler und Systeme Kühlerauswahl / Choice of cooler / Choix du refroidisseur 1. Die dargestellten Leistungskurven basieren auf einer Wassereintrittstemperatur von 25°C, einem Öl-/ Wasserverhältnis von 2:1 und einer durchschnittlichen Ölviskosität von 22cSt. Beispiel: Das Öl verläßt den Kühler mit einer Temperatur von 50°C bei einer Kühlwassertemperatur von 25°C (50°C - 25°C = 25°C). Ein Öl-/Wasserverhältnis von 2:1 bedeutet, daß pro 1l/min umgewälztes Öl ein Kühlwasserfluß von mindestens 0,5l/min erforderlich ist, um die dargestellten Kurven zu erhalten. 1. The performance data...

 Open the catalog to page 5
Serie AM-6

Ihr Partner für Kühler und Systeme Geräteabmessungen / Unit dimensions / Dimensions des appareils A Y IST AUF DER GEGENÜBER LIEGENDEN SEITE UNTER DER MITTELLINIE

 Open the catalog to page 6
Serie AM-7

Ihr Partner für Kühler und Systeme Geräteabmessungen / Unit dimensions / Dimensions des appareils mm / BSPP

 Open the catalog to page 7
Serie AM-8

advanced quality customized designs made in europe Ihr Partner für Kühler und Systeme Bestellschlüssel / Ordering code / Code de commande SS - U - AM - 1014 - A - 6 - F - CU - B Deckel / Cap / Bouchon - = Standard B = Bronze / Bronze / Bronze SB = Edelstahl / Stainless steel / Acier inox SS = Komplettkühler in Edelstahl / Complete cooler in stainless steel / Refroidisseur complet en acier inox U = U-Rohr / U-tube / U-tube (Baugröße / Unit size / Taille 600-1600) Rohrmaterial / Pipe material / Matérial de tube CU-NI = Kupfer-Nickel / Copper-Nickel / Cuivre-Nickel CU = Kupfer / Copper / Cuivre...

 Open the catalog to page 8

All Universal Hydraulik GmbH catalogs and technical brochures

  1. LKM

    1  Page

  2. LKI/LKI-HYD

    13  Pages

  3. UHD 160

    12  Pages

  4. SSP/ HSSP

    7  Pages

  5. UKC-G

    2  Pages

  6. CKM/FS

    2  Pages

  7. EK/SC UK/UKT

    10  Pages

  8. EKM/SKM

    12  Pages

  9. SCM

    7  Pages

  10. TFS/A

    4  Pages

  11. EK/SC

    10  Pages

  12. LKFM

    1  Page

  13. Serie SCM/FS

    2  Pages

  14. Serie SCM

    7  Pages

  15. Serie UKCG

    2  Pages

  16. SSP series

    4  Pages

  17. Serie WRV

    2  Pages

  18. Serie UKTM

    8  Pages

  19. CK-series

    4  Pages

  20. Serie UKM

    8  Pages

  21. Serie CKMFS

    2  Pages

  22. Serie TL

    4  Pages

  23. Serie TFSA

    4  Pages

  24. Serie PWT

    2  Pages

  25. Serie LKM

    12  Pages

  26. Serie LKI

    12  Pages

  27. Serie LKI-HYD

    8  Pages

  28. Serie EKM/SKM

    10  Pages

  29. Serie EDH

    8  Pages

  30. Serie ECM

    8  Pages

  31. Serie CKM

    8  Pages

  32. PTÖK series

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.