advanced quality customized designs made in europe Oil/Air heat exchangers OIL-AIR COOLING I Low noise level I High performance I Low cost The cut-away perspective shows the housing with thick steel walls aun high-performance cooling chamber incorporating copper pipes and aluminium cooling ribs.
Open the catalog to page 1
Product description Product description With this new generation of Universal Hydraulik LKI oil-coolers, the manufacturers have succeeded in reducing the noise level. These coolers are ideally suited for stationary installations - for the cooling of hydraulic or lubricating oils. The range has been extended to include slowrunning ventilators, and the housings have been optimised, in order to produce the very low noise level. In order to make the cooler range as comprehensive as possible, the smaller models are also available as single or dual versions, thus covering oil-cooling requirements...
Open the catalog to page 2
Your Partner for coolers and systems Flow Rate The calculation of the specific cooling performance is based on an oil temperature of 140° F, an ambient temperature of 68° F - and there- fore a temperature difference of 72° F. The figures apply to ISO VG32 hydraulic oil with 30 cSt. For variances, Ap is multiplied by the correc- tion factor f from the diagram on Page 3.
Open the catalog to page 3
Lifting and transport points 9,65 Motor 0,5HP; 2-pol Nema Frame Size 56C 9,65 Motor 0,33HP; 4-pol Nema Frame Size 56C LKI 100 - 600: lateral internal-thread oil connections Technical data Model Motor performance Power consumption Noise level* * may vary by ±3 dB(A) due to room characteristics, own frequencies, oil connections, viscosities etc.
Open the catalog to page 4
LKI-300/400 Dimensions Lifting and transport points 9,65 Motor 0,5HP; 4-pol Nema Frame Size 56C 9,65 Motor 0,5HP; 6-pol Nema Frame Size 56C LKI 100 - 600: lateral internal-thread oil connections Technical data Model Motor performance Power consumption Noise level* * may vary by ±3 dB(A) due to room characteristics, own frequencies, oil connections, viscosities etc.
Open the catalog to page 5
LKI-500/600 Dimensions Lifting and transport points 11,5 Motor 1HP; 4-pol Nema Frame Size 143TC 9,65 Motor 0,5HP; 6-pol Nema Frame Size 56C LKI 100 - 600: lateral internal-thread oil connections Technical data Model Motor performance Power consumption Noise level* * may vary by ±3 dB(A) due to room characteristics, own frequencies, oil connections, viscosities etc.
Open the catalog to page 6
LKI-700 Dimensions Lifting and transport points 35,43 31,89 29,92 14,1 Motor 1,5HP; 6-pol Nema Frame Size 182TC 13,14 Motor 1HP; 8-pol Nema Frame Size 182T LKI 700 - 1000: lateral internal-thread oil connections and SAE flange at front or rear Technical data Model Motor performance Power consumption Noise level* * may vary by ±3 dB(A) due to room characteristics, own frequencies, oil connections, viscosities etc.
Open the catalog to page 7
LKI-800 Dimensions Lifting and transport points 39,37 35,83 33,86 13,5 Motor 2HP; 6-pol Nema Frame Size 184TC 13,14 Motor 1HP; 8-pol Nema Frame Size 182T LKI 700 - 1000: lateral internal-thread oil connections and SAE flange at front or rear Technical data Model Motor performance Power consumption Noise level* * may vary by ±3 dB(A) due to room characteristics, own frequencies, oil connections, viscosities etc.
Open the catalog to page 8
LKI-900 Dimensions Lifting and transport points 43,31 39,76 37,80 16,2 Motor 5HP; 6-pol Nema Frame Size 215TC 14,31 Motor 2HP; 8-pol Nema Frame Size 213T LKI 700 - 1000: lateral internal-thread oil connections and SAE flange at front or rear Technical data Model Motor performance Power consumption Noise level* * may vary by ±3 dB(A) due to room characteristics, own frequencies, oil connections, viscosities etc.
Open the catalog to page 9
LKI-1000 Dimensions Lifting and transport points 47,24 43,70 41,73 16,2 Motor 5HP; 6-pol Nema Frame Size 215TC 14,31 Motor 2HP; 8-pol Nema Frame Size 213T LKI 700 - 1000: lateral internal-thread oil connections and SAE flange at front or rear Technical data Model Motor performance Power consumption Noise level* * may vary by ±3 dB(A) due to room characteristics, own frequencies, oil connections, viscosities etc.
Open the catalog to page 10
Hydraulic Motor Information Model Motor performance * may vary by ±3 dB(A) due to room characteristics, own frequencies, oil connections, viscosities etc.
Open the catalog to page 11
advanced quality customized designs Ordering code UNIVERSAL • ijijiiji Your Partner for coolers and systems Cooler with hydraulic motor = LKHYD Unit Size flat version, with mounting Cooling block Cooling block Motor type Motors with special voltages, hydraulic and explosion protection available on request. All motors comply with EISA regulations. The technical data of this sheet is depending on the described operational conditions and individual cases. At different operational conditions and differing individual cases contact UniversalHydraulik. Technical modifications reserved. Please also...
Open the catalog to page 12All Universal Hydraulik GmbH catalogs and technical brochures
-
LKM
1 Pages
-
LKI/LKI-HYD
13 Pages
-
UHD 160
12 Pages
-
SSP/ HSSP
7 Pages
-
UKC-G
2 Pages
-
CKM/FS
2 Pages
-
EK/SC UK/UKT
10 Pages
-
EKM/SKM
12 Pages
-
SCM
7 Pages
-
COOLING SYSTEMS
2 Pages
-
TFS/A
4 Pages
-
EK/SC
10 Pages
-
LKFM
1 Pages
-
Serie SCM/FS
2 Pages
-
Serie SCM
7 Pages
-
Serie UKCG
2 Pages
-
SSP series
4 Pages
-
Serie WRV
2 Pages
-
Serie UKTM
8 Pages
-
CK-series
4 Pages
-
Serie UKM
8 Pages
-
Serie CKMFS
2 Pages
-
Serie TL
4 Pages
-
Serie TFSA
4 Pages
-
Serie PWT
2 Pages
-
Serie LKM
12 Pages
-
Serie LKI
12 Pages
-
Serie LKI-HYD
8 Pages
-
Serie EKM/SKM
10 Pages
-
Serie EDH
8 Pages
-
Serie ECM
8 Pages
-
Serie CKM
8 Pages
-
PTÖK series
6 Pages
Archived catalogs
-
Serie AM
8 Pages