1. Catalogs
  2. Universal Hydraulik GmbH
  3. Heat Exchanger Series EKM - SCM UKM - UKTM
video corpo
cad

Heat Exchanger Series EKM - SCM UKM - UKTM

Heat Exchanger Series EKM - SCM UKM - UKTM
1 / 21 PagesView full catalog

Heat Exchanger Series EKM - SCM UKM - UKTM

Product catalog summary
Overview
The document details the Hybrid Cooling heat exchanger series, emphasizing its advanced design and material options for improved performance and durability. These exchangers are suitable for various industrial applications, offering enhanced heat exchange efficiency and a compact design.
Specifications
  • Shell Side (Oil): Enhanced performance with fin-technic.
  • Tube Side (Water): Long service life and easy cleaning with materials like Cu, CN, TI, and SS.
  • Heat Capacity: Up to 5000 kW.
  • Flow Rates: Up to 2200 l/min on the shell side.
  • Design: Compact and available as a failsafe heat exchanger.
Materials and Construction
  • Shell: Standard steel with stainless steel option.
  • Tube Sheet: Options include steel, stainless steel, and brass.
  • Tubes: Made from CuNi 90/10, stainless steel, or copper.
  • End Caps: Cast iron with options for stainless steel or chemically nickel-plated cast iron.
Product Features
  • Aluminium fins increase the heat exchange surface.
  • Removable end caps for easy tube cleaning.
  • Maximum pressure: Oil 35 bar, Water 16 bar (higher pressure available on demand).
  • High-quality materials and tested five times during production.
Options
  • Sea water resistant version.
  • Certifications for marine applications (e.g., Bureau Veritas, ABS, DNVGL).
  • Compressed-air application.
  • Fully stainless steel or chemically nickel-plated versions.
  • 3.1 certification, hydrotest, ATEX, and ASME certifications available on request.
  • Internal bypass and titanium parts.
  • Fail-safe version.
Unit Dimensions
The document includes detailed dimensions for various series (EKM-500, EKM-700, EKM-1000, EKM-1200, EKM-1400, EKM-1700) with specifications for each type, including measurements for medium to be cooled, cooled medium, cooling water inlet, and outlet.
Procedures and Recommendations
  • Installation caution is advised to prevent damage, and zinc anodes are recommended for seawater versions.
  • Pressure resistance details are available in component drawings, and operational conditions may affect technical data.
Ordering Information
  • Ordering codes include details on removable cartridges, unit sizes, bypass versions, tube materials, and end cap materials.
  • Connection types and sizes are specified for both shell and tube sides, with various thread and flange options available.
Additional Information
  • Heat exchangers are available in different series, each with specific features such as straight or U-formed water tubes.
  • Contact information for Universal Hydraulik in Europe and the USA is provided for sales and support.
See more

Catalog excerpts

Heat Exchanger Series EKM - SCM UKM - UKTM-1

advanced quality customized designs made in europe and usa HYBRID COOLING I Shell side (oil): increased performance due to fin-technic I Tube side (water): long service life; easy to clean I Tube side (water): various Material options: for example CU-/CN-/TI-/SS I On-and in-tank mounted cooler Your Partner for coolers and systems Heat Exchanger Series I Heat capacity up to 5000 kW I Flow rates up to 2200 l/min (Shell side) I Compact design I also available as failsafe heat exchanger

 Open the catalog to page 1
Heat Exchanger Series EKM - SCM UKM - UKTM-2

Product description The Hybrid series is a logical further development of a shell & tube heat exchanger for a wide range of industrial applications. Aluminium fins, which are pushed over the tube bundle, connected by force, lead to an increased heat exchange surface. This is why the series is so efficient. The hybrid-design series is able to reach a heat output up to 5000 kW with a smaller footprint than a bare tube cooler. Product features I I I I I I I Aluminium fins ensure a larger heat exchange surface Heat output capacity up to 5000 kW Tube side (Water): flow rate up to 2200 l/min Removable...

 Open the catalog to page 2
Heat Exchanger Series EKM - SCM UKM - UKTM-3

C - Cooling water „inlet“ D - Cooling water „outlet“

 Open the catalog to page 3
Heat Exchanger Series EKM - SCM UKM - UKTM-4

C - Cooling water „inlet“ D - Cooling water „outlet“

 Open the catalog to page 4
Heat Exchanger Series EKM - SCM UKM - UKTM-9

B - Cooled Medium C - Cooling water „inlet“ D - Cooling water „outlet“

 Open the catalog to page 9
Heat Exchanger Series EKM - SCM UKM - UKTM-11

B - Cooled Medium C - Cooling water „inlet“ D - Cooling water „outlet“

 Open the catalog to page 11
Heat Exchanger Series EKM - SCM UKM - UKTM-12

A variable variable variable variable variable A variable variable variable variable variable A variable variable variable variable variable D variable variable variable variable variable D variable variable variable variable variable D variable variable variable variable variable B - Cooled Medium C - Cooling water „inlet“ D - Cooling water „outlet“

 Open the catalog to page 12
Heat Exchanger Series EKM - SCM UKM - UKTM-13

C - Cooling water „inlet“ D - Cooling water „outlet“

 Open the catalog to page 13
Heat Exchanger Series EKM - SCM UKM - UKTM-14

Unit dimensions UKM-1000-Series Type C - Cooling water „inlet“ D - Cooling water „outl

 Open the catalog to page 14
Heat Exchanger Series EKM - SCM UKM - UKTM-15

C - Cooling water „inlet“ D - Cooling water „outlet“

 Open the catalog to page 15
Heat Exchanger Series EKM - SCM UKM - UKTM-16

Unit dimensions UKTM-500/700-Series Type Water Inlet - Outlet B - Cooled Medium C - Cooling water „inlet“ D - Cooling water „outlet“

 Open the catalog to page 16
Heat Exchanger Series EKM - SCM UKM - UKTM-17

Water inlet - outlet B - Cooled Medium C - Cooling water „inlet“ ØO D - Cooling water „outlet“

 Open the catalog to page 17
Heat Exchanger Series EKM - SCM UKM - UKTM-18

Water inlet - outlet B - Cooled Medium C - Cooling water „inlet“ D - Cooling water „outlet“

 Open the catalog to page 18
Heat Exchanger Series EKM - SCM UKM - UKTM-19

advanced quality customized designs made in europe and usa Technical data Caution: Incorrect installation can lead to damage to the cooler. For the seawater version, zinc anodes should be provided on the waterside. Exact information for the pressure resistance can be found in the respective component drawings. Maximum operating Pressure Shell = up to 35 bar Tubes = up to 16 bar Operating temperature = 5 - 95 °C Maximum flow rate (in l/min): Oil Shell Water Tubes CuNi 90/10 (CN)/Stainless steel (SS) O T F Water Tubes Copper (CU) O Water Tubes CuNi 90/10 (CN)/ Stainless steel (SS) O T F Sea water...

 Open the catalog to page 19
Heat Exchanger Series EKM - SCM UKM - UKTM-20

advanced quality customized designs made in europe and usa Your Partner for coolers and systems Ordering code SS - EKM - 1036 - 6 - O - CN - R - W - SW (S:G112 - T:G114) Connection tube side see following page Complete cooler Stainless steel incl. Aluminium Fins Connection shell side see following page Material of end caps SW = Cast iron (nickel coating treatment) SWBZ = Sea water resistant gun metal end caps + zinc anode SS = Stainless steel Without data = Cast iron or steel Series abbreviation EKM-Series SCM-Series UKM-Series UKTM-Series Material of the tube sheet W = Brass SS = Stainless steel...

 Open the catalog to page 20
Heat Exchanger Series EKM - SCM UKM - UKTM-21

advanced quality customized designs made in europe and usa Your Partner for coolers and systems Connection designation EKM - 1036 - O - CN (S:G112 - T:G114) Type code acc. UH-data sheet (see previous page) Connection type and connection size, shell side Connection type and connection size, tube side Connection table G BSPP thread: G1/8" = G18 Universal Hydraulik USA, Corp. Fort Meigs Business Center . 25651 Fort Meigs Road, Suite A Perrysburg, OH 43551 Phone: 419 873 63 40 . Fax: 419 873 63 42 email: i

 Open the catalog to page 21

All Universal Hydraulik GmbH catalogs and technical brochures

  1. LKM

    1  Page

  2. LKI/LKI-HYD

    13  Pages

  3. UHD 160

    12  Pages

  4. SSP/ HSSP

    7  Pages

  5. UKC-G

    2  Pages

  6. CKM/FS

    2  Pages

  7. EK/SC UK/UKT

    10  Pages

  8. EKM/SKM

    12  Pages

  9. SCM

    7  Pages

  10. TFS/A

    4  Pages

  11. EK/SC

    10  Pages

  12. LKFM

    1  Page

  13. Serie SCM/FS

    2  Pages

  14. Serie SCM

    7  Pages

  15. Serie UKCG

    2  Pages

  16. SSP series

    4  Pages

  17. Serie WRV

    2  Pages

  18. Serie UKTM

    8  Pages

  19. CK-series

    4  Pages

  20. Serie UKM

    8  Pages

  21. Serie CKMFS

    2  Pages

  22. Serie TL

    4  Pages

  23. Serie TFSA

    4  Pages

  24. Serie PWT

    2  Pages

  25. Serie LKM

    12  Pages

  26. Serie LKI

    12  Pages

  27. Serie LKI-HYD

    8  Pages

  28. Serie EKM/SKM

    10  Pages

  29. Serie EDH

    8  Pages

  30. Serie ECM

    8  Pages

  31. Serie CKM

    8  Pages

  32. PTÖK series

    6  Pages

Archived catalogs

  1. Serie AM

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.