FLOMEC® QSE
2Pages

{{requestButtons}}

Catalog excerpts

FLOMEC® QSE - 1

PRODUCT IDENTIFIER QSE = Electro-Magnetic Flow Meter NPT = NPT (Male) (½” to 2” Only) BSP = BSPP (Male) (ISO 228) (½” to 2” Only) FAP = ANSI Flange - Polymer (3” & 4” Only) ELECTRONIC CHOICE 4 09 = 2-Button Integral Display, Field Configurable (Cumulative, Batch & Rate) and Integral Pulse Transmitter (Open Collector Square Wave), Includes Four Strain Reliefs QSE MAG FLOWMETER The QSE Mag Series is a dependable highly accurate electromagnetic flowmeter designed for flow and usage monitoring in commercial applications. The NorylTM housing and flow tube offer a lightweight, easyto-install Mag Meter that is resistant to heat and compatible with many water-based liquid solutions. The QSE Mag Meter monitors flow rate and total flow in a wide variety of applications including: HVAC, Turf/ Irrigation and other water reclamation applications. QB = Integral Pulse Transmitter (Open Collector Square Wave), Includes Four Strain Reliefs COMMUNICATION CHOICE Q1 = Integrates with Any Electronic Choice QSI Module: Bluetooth®, Coil/Digital Pulse Input, Pulse Output (Flow or Energy & Scalable), RS485 (Modbus RDU or BACnet® MS/TP)), Temperature Inputs, BTU Calculator. Energy Use Computation Note: Energy Use Computation Requires Temperature Sensor Probes (Select Probes Below) Q2 = Integrates with Any Electronic Choice QSI Module: Bluetooth®, Coil/Digital Pulse Input, Pulse Output (Flow or Energy & Scalable), Temperature Inputs, BTU (Heat) Calculator. Energy Use Computation Note: Energy Use Computation Requires Temperature Sensor Probes (Select Probes Below) • Low investment and operating costs Q3 = Integrates with Any Electronic Choice QSI Module: Bluetooth®, Coil/Digital Pulse Input, Pulse Output (Scalable), 4-20mA. • ± 0.5% Accuracy of Reading (from 0.25 fps to 15 fps [0.08 to 4.6 m/s]) • Wide turndown ratio of 60:1 • Non-intrusive, no moving parts to wear out, maintenance, repair costs low and tolerates high flows without damage • The slightly modified bore permits unobstructed flow and minimizes flow disturbances and straight pipe requirements • 7 line sizes (1/2” to 4”) ½”, ¾”, 1”, 1-1/2”, 2”, 3", & 4” • Housing ported with “Thermal Well Supports” for sensors (Energy Management) • Compatible with GPI 09 Electronics Display or FLOMEC QSI I/O Board 6 1 = Integrates with QSI Communications Choice for Energy Use Computation (2ea) 1" (25 mm) Long Temperature Sensor Probes w/Cables (10 ft. [3 m]) (Customer Installed), Used with 1/2" through 2" Meters TEMPERATURE SENSOR PROBES 2 = Integrates with QSI Communications Choice for Energy Use Computation (2ea) 2" (50 mm) Long Temperature Sensor Probes w/Cables (10 ft. [3 m]) (Customer Installed), Used with 3" and 4" Meters X = No Temperature Probes PACKAGING (Auto Select)

Open the catalog to page 1
FLOMEC® QSE - 2

Fitting Type: Operating Temperature Range: 1/2” to 2” - NPT (Male), BSPP (Male) (ISO 228) Ambient Temperature Range: 3” & 4” 150# ANSI Flanged - Polymer Flange Typical K-Factor: Recommeded Plastic Flange Bolt Torque: Pipe Sizes: Pressure Rating: Power Supply: Externally Powered Voltage Supply (Min): 12V (dc) Voltage Supply (Max): 36V (dc) ±0.5% of Reading between 0.25 fps and 15 fps (0.08 m/s and 4.6 m/s) (Reference Owner's Manual for complete accuracy and uncertainty specifications) Max current consumption (QSE with QSB): 75mA Wetted Materials: EPDM O-Rings Output Frequency Range: Max...

Open the catalog to page 2

All UNIVERSAL FLOW MONITORS catalogs and technical brochures

  1. TM SERIES

    2 Pages

  2. G2 SERIES

    2 Pages

  3. FS series

    4 Pages

  4. FP series

    4 Pages

  5. FD series

    4 Pages

  6. cam 5400

    2 Pages

  7. MX

    6 Pages

  8. XHF

    5 Pages

  9. LN series

    5 Pages

  10. CAM 5200

    2 Pages

  11. CPM

    4 Pages

  12. CP V8

    2 Pages

  13. LL AX0 lube

    3 Pages

  14. Flow Sensor

    2 Pages

Archived catalogs