Catalog excerpts
U N I V E R S A L Maximum ow ranges from Max pressure Temperature range ® F L O W 300-600 GPM (1100-2300 LPM) 200 PSI (13 Bar) 32-210°F (2-99°C) M O N I T O R S CP 3-4 Inch ™ UNIVERSAL Flow Monitors ® CoolPoint Vortex Shedding Flowmeter Coolpoint™ with Rotatable Enclosure Description Instrument Specications This owmeter is made for water, water/glycol coolant or low viscosity uids. It has the following features: • Flow transmitter 4-20 mA • Solid state relay congureable as alarm set points or pulse output • LED digital display • No moving parts to clog or wear • Certied CSA and CE • Optional temperature transmitter • Electrical Specications • • • Input Power: 10 - 30 VDC @ 80 mA Output: 4-20 mA with 25 pulses per gallon from the solid state relay Electrical Connection Pin Connector (standard) Pigtails (optional) Junction Box with terminal strip (optional) Material Specications Flow bodies of brass with PVDF sensors and Viton® seals standard. PEEK sensors used for high temp for uids above 150° F. Flow Visual readout: 3 digit LED, 0.3" digit height Response time: 7.5 seconds Deadband for Alarm: 5% of full scale (maximum ow) Accuracy: ±2% of full scale (maximum ow) Repeatability: ±.25% of indicated ow Turndown (ratio of maximum to minimum): 10:1 • Temperature (CT units only) Response time: 1.8 seconds Deadband for Alarm: ±2% Accuracy: ±1% F.S. Repeatability: ± .25% of indicated ow Output: 4 mA @32°F, 20mA @210°F linear • Pressure 200 PSIG (13 Bar) operating pressure • General Fluid temperature limits: 35-150° F (2-66° C) standard, 150-210° F (66-99° C) optional. • Back pressure of 10 PSIG required. (See manual for elevated temperature.) Enclosure rating: IP 65, Type 1, 3, 4, 12 and 13 • Pipe Connections: ANSI Class 150 R.F. Flanges User-Congurable Options Features that are selectable on 4-20 mA/pulse out units include: • Selectable alarm state (N.O. or N.C.) • Set point or pulse output • Rotatable control box standard for all units • Engineering units (GPM, LPM) Viton® is a registered trademark for DuPont Performance Elastomers.
Open the catalog to page 1INSTALLATION DRAWING – 3" AND 4" PORT SIZE H FLANGE DIA. CONTROL BOX CAN BE ROTATED TO ANY OF (4) DETENTED POSITIONS IN 90° INCREMENTS FLOW IN FLOW OUT Class 150 Raised Face Flange E F C Option C3 Option C3 JUNCTION BOX B .500-14 NPT CONDUIT CONNECTION A Size A B CP24 CT24 7.75 [197mm] 3.88 [99 mm] C D G D E F G H 8.90 11.13 4.44 6.03 5.73 7.50 [226 mm] [283 mm] [113 mm] [153 mm] [146 mm] [191 mm] CP32 10.75 5.38 9.46 12.57 4.44 6.03 6.43 9 CT32 [273 mm] [137 mm] [240 mm] [319 mm] [113 mm] [153 mm] [163 mm] [229 mm] ACCESSORY CABLES AVAILABLE FOR PIN CONNECTOR METERS Series Description CP 5...
Open the catalog to page 3PIN CONNECTOR PINOUTS CP (FLOW ONLY) WHITE 4-20 mA FLOW SIGNAL OUT BROWN 2 1 5 GRAY +24 Vdc SUPPLY * FLOW RELAY CONTACT Use pull up resistor (2-10K Ohm) to turn open collector signal (ow relay contact) into a pulse. 4 3 BLACK BLUE FLOW RELAY CONTACT SUPPLY GROUND CONFIGURATION: • 1: + 24 VDC power supply • 2: 4-20 mA ow signal out • 3: supply ground • 4: ow relay contact • 5: ow relay contact CT (FLOW AND TEMPERATURE) WHITE BROWN 2 1 5 GRAY BLACK BLUE N I V E R S A L ® F L O W +24 Vdc SUPPLY FLOW RELAY CONTACT 4 3 U 4-20 mA FLOW SIGNAL OUT M O N I T O R S FLOW RELAY CONTACT SUPPLY & CHASSIS...
Open the catalog to page 4All UNIVERSAL FLOW MONITORS catalogs and technical brochures
-
FLOMEC® QSE
2 Pages
-
TM SERIES
2 Pages
-
G2 SERIES
2 Pages
-
Piston Inline PI
6 Pages
-
FS series
4 Pages
-
FP series
4 Pages
-
FD series
4 Pages
-
Coolpoint Large Series
4 Pages
-
cam 5400
2 Pages
-
MX
6 Pages
-
XHF
5 Pages
-
LN series
5 Pages
-
CAM 5200
2 Pages
-
OFS simplified single gas
3 Pages
-
CPM
4 Pages
-
Insite Lit no TX
6 Pages
-
P420 Plastic Vortex Meter
2 Pages
-
CP V8
2 Pages
-
LL AX0 lube
3 Pages
-
Flow Sensor
2 Pages
-
Vortex Shedding Flowmeter
4 Pages