Coolpoint Large Series
4Pages

{{requestButtons}}

Catalog excerpts

Coolpoint Large Series - 1

Maximum ow ranges from Max pressure Temperature range UNIVERSAL Flow Monitors ® Vortex Shedding Flowmeter Coolpoint™ with Rotatable Enclosure Instrument Specications This owmeter is made for water, water/glycol coolant or low viscosity uids. It has the following features: • Flow transmitter 4-20 mA • Solid state relay congureable as alarm set points or pulse output • LED digital display • No moving parts to clog or wear • Certied CSA and CE • Optional temperature transmitter Electrical Specications • • • Input Power: 10 - 30 VDC @ 80 mA Output: 4-20 mA with 25 pulses per gallon from the solid state relay Electrical Connection Pin Connector (standard) Pigtails (optional) Junction Box with terminal strip (optional) Material Specications Flow bodies of brass with PVDF sensors and Viton® seals standard. PEEK sensors used for high temp for uids above 150° F. Flow Visual readout: 3 digit LED, 0.3" digit height Response time: 7.5 seconds Deadband for Alarm: 5% of full scale (maximum ow) Accuracy: ±2% of full scale (maximum ow) Repeatability: ±.25% of indicated ow Turndown (ratio of maximum to minimum): 10:1 • Temperature (CT units only) Response time: 1.8 seconds Deadband for Alarm: ±2% Accuracy: ±1% F.S. Repeatability: ± .25% of indicated ow Output: 4 mA @32°F, 20mA @210°F linear • Pressure 200 PSIG (13 Bar) operating pressure • General Fluid temperature limits: 35-150° F (2-66° C) standard, 150-210° F (66-99° C) optional. • Back pressure of 10 PSIG required. (See manual for elevated temperature.) Enclosure rating: IP 65, Type 1, 3, 4, 12 and 13 • Pipe Connections: ANSI Class 150 R.F. Flanges User-Congurable Options Features that are selectable on 4-20 mA/pulse out units include: • Selectable alarm state (N.O. or N.C.) • Set point or pulse output • Rotatable control box standard for all units • Engineering units (GPM, LPM) Viton® is a registered trademark for DuPont Performance Elastomers.

Open the catalog to page 1
Coolpoint Large Series - 2

Select the appropriate symbols to build a model code: MODEL CODES FLOW FLOW AND TEMPERATURE Pipe size in inches 3 4 3 4 Model code Connector or conduit box options available -C1*=Pin connector -C2=Pig tails -C3=Conduit box, terminal strip Special options * Indicates default selection. If no selection is made, this option is assumed. Example: CP24 is the same as CP24-C1 PRESSURE DROP (PSID) PRESSURE DROP

Open the catalog to page 2
Coolpoint Large Series - 3

INSTALLATION DRAWING – 3" AND 4" PORT SIZE H FLANGE DIA. CONTROL BOX CAN BE ROTATED TO ANY OF (4) DETENTED POSITIONS IN 90° INCREMENTS FLOW OUT Class 150 Raised Face Flange ACCESSORY CABLES AVAILABLE FOR PIN CONNECTOR METERS Series

Open the catalog to page 3
Coolpoint Large Series - 4

PIN CONNECTOR PINOUTS CP (FLOW ONLY) WHITE * FLOW RELAY CONTACT Use pull up resistor (2-10K Ohm) to turn open collector signal (ow relay contact) into a pulse. BLACK BLUE FLOW RELAY CONTACT SUPPLY GROUND CONFIGURATION: • 1: + 24 VDC power supply • 2: 4-20 mA ow signal out • 3: supply ground • 4: ow relay contact • 5: ow relay contact CT (FLOW AND TEMPERATURE) WHITE BROWN 2 GRAY BLACK BLUE +24 Vdc SUPPLY FLOW RELAY CONTACT FLOW RELAY CONTACT SUPPLY & CHASSIS GROUND CONFIGURATION: • 1: + 24 VDC power supply • 2: 4-20 mA ow signal out • 3: supply & chassis ground • 4: ow relay contact • 5: ow...

Open the catalog to page 4

All UNIVERSAL FLOW MONITORS catalogs and technical brochures

  1. FLOMEC® QSE

    2 Pages

  2. TM SERIES

    2 Pages

  3. G2 SERIES

    2 Pages

  4. FS series

    4 Pages

  5. FP series

    4 Pages

  6. FD series

    4 Pages

  7. cam 5400

    2 Pages

  8. MX

    6 Pages

  9. XHF

    5 Pages

  10. LN series

    5 Pages

  11. CAM 5200

    2 Pages

  12. CPM

    4 Pages

  13. CP V8

    2 Pages

  14. LL AX0 lube

    3 Pages

  15. Flow Sensor

    2 Pages

Archived catalogs