CAM 5200
2Pages

{{requestButtons}}

Catalog excerpts

CAM 5200 - 1

FLOWMETER FOR COMPRESSED-AIR SYSTEMS Digital display Milliamp and pulse outputs No calibration or setup required Complete flowmeter in one package Optional RS-485 output for networking The CAM 5200 clamps onto a pipe, with two flowsensing probes projecting into the pipe through 3/16-in. drilled holes. It seals directly to the pipe; no cutting or welding is required for instal- lation. Because each flowmeter is made and calibrated for a specific size of pipe, the digital display indicates flow directly with no setup or adjustment. The meter measures flow by maintaining one probe warmer than the other. It calculates the mass velocity from the amount of heat required, and then calculates the flow on the basis of pipe area. The flow rate, in scfm, is shown on a large, four-digit display; a 4-20 mA output and a pulse output permit remote display, totalizing and data collection. (a) Accuracy will be reduced when flow is outside of specified range. Milliamp scale ranges differ. 5 percent of reading plus one percent of full scale at air temperatures between 40 and 120 Operating pressure: 15 to 170 psig for best accuracy 200 psig maximum on Sch. 40 steel and Type Input power: Output resistance: Wetted materials: Stainless steel, gold, thermal epoxy and Viton® Ring material: Response time: One second to 63 percent of final value Viton® is a registered trademark for DuPont Performance Elastomers.

Open the catalog to page 1
CAM 5200 - 2

APPLICATION MILLIAMP AND PULSE OUTPUTS The meter is designed for use with compressed air and nitrogen. If the meter will be used at pressures below 15 psig, consult factory about velocity limitations. The air must be free of oil, dirt that could foul the probes, and suspended water droplets. If the meter must be mounted near a compressor, isolate it from the compressor by placing it downstream of a dryer or storage tank. Each meter is calibrated for a specic size and type of pipe. The meter has an isolated, unpowered, milliamp output. This output may, optionally, be powered from the...

Open the catalog to page 2

All UNIVERSAL FLOW MONITORS catalogs and technical brochures

  1. FLOMEC® QSE

    2 Pages

  2. TM SERIES

    2 Pages

  3. G2 SERIES

    2 Pages

  4. FS series

    4 Pages

  5. FP series

    4 Pages

  6. FD series

    4 Pages

  7. cam 5400

    2 Pages

  8. MX

    6 Pages

  9. XHF

    5 Pages

  10. LN series

    5 Pages

  11. CPM

    4 Pages

  12. CP V8

    2 Pages

  13. LL AX0 lube

    3 Pages

  14. Flow Sensor

    2 Pages

Archived catalogs