UFL-UHL_UNIVERSAL Manual Power clamps
11Pages

{{requestButtons}}

Catalog excerpts

UFL-UHL_UNIVERSAL Manual Power clamps - 1

UFL-UHL UNIVERSAL Manual Power clamps UF/UH = UNIVERSAL Manual Power clamps fully adjustable opening angle: 0° to 135° max The opening angle range may vary according to the arm position and style UNIVER GROUP C = Central , 15 mm offset N = No sensor (with protection plate) D = Right, 15 mm offset E = Electronic sensor with M12 S = Left, 15 mm offset swivel connector E = Central, 45 mm offset F = Right, 45 mm offset L = Left, 45 mm offset N = No arm X = Central, oversized dowel holes Ø 8 H7, 15 mm offset Y = Right, oversized dowel holes Ø 8 H7, 15 mm offset Z = Left, oversized dowel holes Ø 8 H7, 15 mm offset

Open the catalog to page 1
UFL-UHL_UNIVERSAL Manual Power clamps - 2

UNIVERSAL Manual clamp MinVMax. operating pressure: 0,4 / 0,6 MPa Opening angle: adjustable With manual lever Electronic sensor with M12 swivel connector that can be orientated at 0°or 90° * : TOLERANCE BETWEEN DOWEL HOLES ± 0.02, TO SCREW HOLES ± 0.1 ** : AREA TO ACCESS ANGLE ADJUSTMENT *** : DIMENSIONS TO BE RESPECTED IN CASE OTHER MANUAL LEVERS ARE USED Subject to technical modifications without notice

Open the catalog to page 2
UFL-UHL_UNIVERSAL Manual Power clamps - 3

UNIVERSAL Manual clamp MinVMax. operating pressure: 0,4 / 0,6 MPa Opening angle: adjustable With manual lever Electronic sensor with M12 swivel connector that can be orientated at 0°or 90° * : TOLERANCE BETWEEN DOWEL HOLES ± 0.02, TO SCREW HOLES ± 0.1 ** : AREA TO ACCESS ANGLE ADJUSTMENT *** : DIMENSIONS TO BE RESPECTED IN CASE OTHER MANUAL LEVERS ARE USED Subject to technical modifications without notice

Open the catalog to page 3
UFL-UHL_UNIVERSAL Manual Power clamps - 4

UNIVERSAL Manual clamp Mln./Max. operating pressure: 0,4 / 0,6 MPa Opening angle: adjustable from 0° to 105° Horizontal arm mount position With manual lever Electronic sensor with M12 swivel connector that can be orientated at 0°or 90° * : TOLERANCE BETWEEN DOWEL HOLES ± 0.02, TO SCREW HOLES ± 0.1 * * : AREA TO ACCESS ANGLE ADJUSTMENT *** : DIMENSIONS TO BE RESPECTED IN CASE OTHER MANUAL LEVERS ARE USED Subject to technical modifications without notice

Open the catalog to page 4
UFL-UHL_UNIVERSAL Manual Power clamps - 5

Min./Max. operating pressure: 0,4 / 0,6 MPa Opening angle: adjustable from 0° to 105° Horizontal arm mount position With manual lever Electronic sensor with M12 swivel connector that can be orientated at 0°or 90° * : TOLERANCE BETWEEN DOWEL HOLES ± 0.02, TO SCREW HOLES ± 0.1 * * : AREA TO ACCESS ANGLE ADJUSTMENT *** : DIMENSIONS TO BE RESPECTED IN CASE OTHER MANUAL LEVERS ARE USED Subject to technical modifications without notice

Open the catalog to page 5
UFL-UHL_UNIVERSAL Manual Power clamps - 6

Min./Max. operating pressure: 0,4 / 0,6 MPa Opening angle: adjustable from 0° to 105° Horizontal arm mount position With manual lever Electronic sensor with M12 swivel connector that can be orientated at 0°or 90° * : TOLERANCE BETWEEN DOWEL HOLES ± 0.02, TO SCREW HOLES ± 0.1 * * : AREA TO ACCESS ANGLE ADJUSTMENT *** : DIMENSIONS TO BE RESPECTED IN CASE OTHER MANUAL LEVERS ARE USED Subject to technical modifications without notice

Open the catalog to page 6
UFL-UHL_UNIVERSAL Manual Power clamps - 7

UNIVERSAL Manual clamp arm at 45 mm from pivot point Min./Max. operating pressure: 0,4 / 0,6 MPa Opening angle: adjustable from 0° to 105° Horizontal arm mount position With manual lever Electronic sensor with M12 swivel connector that can be orientated at 0°or 90° * : TOLERANCE BETWEEN DOWEL HOLES ± 0.02, TO SCREW HOLES ± 0.1 * * : AREA TO ACCESS ANGLE ADJUSTMENT *** : DIMENSIONS TO BE RESPECTED IN CASE OTHER MANUAL LEVERS ARE USED Subject to technical modifications without notice

Open the catalog to page 7
UFL-UHL_UNIVERSAL Manual Power clamps - 8

UNIVERSAL Manual clamp Min./Max. operating pressure: 0,4 / 0,6 MPa Opening angle: adjustable from 0° to 135° Vertical arm mount position With manual lever Electronic sensor with M12 swivel connector that can be orientated at 0°or 90° * : TOLERANCE BETWEEN DOWEL HOLES ± 0.02, TO SCREW HOLES ± 0.1 * * : AREA TO ACCESS ANGLE ADJUSTMENT *** : DIMENSIONS TO BE RESPECTED IN CASE OTHER MANUAL LEVERS ARE USED Subject to technical modifications without notice

Open the catalog to page 8
UFL-UHL_UNIVERSAL Manual Power clamps - 9

Min./Max. operating pressure: 0,4 / 0,6 MPa Opening angle: adjustable from 0° to 135° Vertical arm mount position With manual lever Electronic sensor with M12 swivel connector that can be orientated at 0°or 90° * : TOLERANCE BETWEEN DOWEL HOLES ± 0.02, TO SCREW HOLES ± 0.1 * * : AREA TO ACCESS ANGLE ADJUSTMENT *** : DIMENSIONS TO BE RESPECTED IN CASE OTHER MANUAL LEVERS ARE USED Subject to technical modifications without notice

Open the catalog to page 9
UFL-UHL_UNIVERSAL Manual Power clamps - 10

UNIVERSAL Manual clamp Min./Max. operating pressure: 0,4 / 0,6 MPa Opening angle: adjustable from 0° to 135° Vertical arm mount position With manual lever Electronic sensor with M12 swivel connector that can be orientated at 0°or 90° * : TOLERANCE BETWEEN DOWEL HOLES ± 0.02, TO SCREW HOLES ± 0.1 * * : AREA TO ACCESS ANGLE ADJUSTMENT *** : DIMENSIONS TO BE RESPECTED IN CASE OTHER MANUAL LEVERS ARE USED Subject to technical modifications without notice

Open the catalog to page 10
UFL-UHL_UNIVERSAL Manual Power clamps - 11

UNIVERSAL Manual clamp arm at 45 mm from pivot point Min./Max. operating pressure: 0,4 / 0,6 MPa Opening angle: adjustable from 0° to 135° Vertical arm mount position With manual lever Electronic sensor with M12 swivel connector that can be orientated at 0°or 90° * : TOLERANCE BETWEEN DOWEL HOLES ± 0.02, TO SCREW HOLES ± 0.1 * * : AREA TO ACCESS ANGLE ADJUSTMENT *** : DIMENSIONS TO BE RESPECTED IN CASE OTHER MANUAL LEVERS ARE USED Subject to technical modifications without notice

Open the catalog to page 11

All UNIVER Group catalogs and technical brochures

  1. JLE

    5 Pages

  2. HZRS

    2 Pages

  3. HZ9N

    1 Pages

  4. HE/HF tubes

    1 Pages

  5. PRODUCT RANGE

    44 Pages

  6. NEWS 2017-2018

    32 Pages

  7. NEWS 2016

    16 Pages

  8. Product range

    44 Pages

  9. NEWS 2017

    32 Pages

  10. Valves

    210 Pages

  11. PRODUCT RANGE

    32 Pages

  12. RISERS

    4 Pages

  13. M series

    1 Pages

  14. POWER PIVOTS

    2 Pages

  15. PIN CLAMPS

    2 Pages

  16. CLAMPS

    2 Pages

  17. ACCESSORIES

    54 Pages

  18. AIR TREATMENT

    14 Pages

  19. HIGH TECH

    75 Pages

  20. CYLINDERS

    67 Pages

  21. fittings

    36 Pages