Overview
Unitronics' UniStream® Built-in series are all-in-one programmable controllers that integrate a CPU, HMI panel, and built-in I/Os. The series includes two versions: UniStream Built-in and UniStream Built-in Pro, which differ in features like system memory, audio jack, video support, web server, and SQL client capabilities.
General Features
The controllers come with resistive color touch-screens, a comprehensive graphic library, built-in trends and gauges, auto-tuned PID, and data tables. They offer multi-level password protection, built-in alarms, and various I/O configurations.
Communication Options
These controllers include built-in Ethernet, USB host, and Mini-B USB device ports, with options to add serial and CANbus ports. They support multiple communication protocols such as CANopen, MODBUS, and EtherNetIP.
Installation Guidelines
Before installation, verify the kit contents and read the guide thoroughly. Ensure proper ventilation and avoid areas with excessive dust, moisture, or heat. Maintain a safe distance from high-voltage cables.
Kit Contents
The kit includes a PLC+HMI controller, mounting brackets, a panel mounting seal, panel supports, power terminal block, I/O terminal blocks (for models with built-in I/Os), and a battery.
Installation Space and Panel Mounting
Allocate space for the controller and any additional modules. Follow specific dimensions for panel cut-outs and ensure proper mounting using the provided brackets.
Battery Installation
The battery is pre-installed but requires user activation by removing a protective tab. Follow ESD precautions during installation or replacement.
Wiring Instructions
Use SELV/PELV/Class 2 power environments. Ensure all wiring is done with power off and use over-current protection. Follow specific guidelines for wiring digital and analog inputs, temperature inputs, and power supply connections.
Environmental and Safety Considerations
Ensure proper earthing and use shielded cables to prevent electromagnetic interference. Follow local regulations for disposal and installation.
RTD Wiring Instructions
Ensure all RTD wires are of the same type, width, and length for accuracy. For 4-wire RTDs, use a 3-wire cable and leave the unused wire unconnected and short.
Relay Outputs Wiring
Use a limited current source or a current limiting device to prevent fire or damage. Relay outputs are in two isolated groups: O0-O3 (CM3) and O4-O7 (CM4). To extend relay contact life, use a clamping diode for DC loads and an RC snubber circuit for AC loads.
Source Transistor Outputs Wiring
An external 24VDC power supply is required. Connect +VO and 0VO terminals as shown in the figure. Outputs O0-O9 share common return 0VO.
Analog Outputs Wiring
Outputs are not isolated and can be set to voltage or current mode independently. Hardware configuration in the software application determines the mode. CM5 should only be used for connecting the analog output load to avoid damage.
Installing and Uninstalling Modules
Refer to the Installation Guides for Uni-I/O™ & Uni-COM™ Modules. Turn off system power before connecting or disconnecting modules. Prevent Electro-Static Discharge (ESD) during installation. For uninstallation, disconnect power, remove wiring, and unscrew mounting brackets carefully.
Disclaimer
Information is provided "as is" without warranty. Unitronics is not liable for any damages arising from the use of this information. Product features and specifications may change without notice.
See more

Catalog excerpts

US7-x10-TA30-1

Installation Guide UniStream® Built-in This guide provides basic installation information for specific UniStream® models with built-in I/O. Technical specifications may be downloaded from the Unitronics website. General Features Unitronics’ UniStream® Built-in series are PLC+HMI All-in-One programmable controllers that comprise a built-in CPU, an HMI panel, and built-in I/Os. The series is available in two versions: UniStream Built-in and UniStream Built-in Pro. Note that a model number that includes: • B5/C5 refers to UniStream Built-in B10/C10 refers to UniStream Built-in Pro. These models offer additional features, detailed below. ▪ Resistive Color Touch-screens ▪ Rich graphic library for HMI design Power Features ▪ Built-in Trends and Gauges, auto-tuned PID, data tables, data sampling, and Recipes ▪ UniApps™: Access & edit data, monitor, troubleshoot & debug and more – via HMI or remotely via VNC ▪ Security: Multi-level password protection ▪ Alarms: Built-in system, ANSI/ISA standards ▪ Built-in I/O configuration, varies according to model ▪ Local I/O via UAG-CX series I/O expansion adapters and standard UniStream Uni-I/O™ modules ▪ Remote I/O using UniStream Remote I/O or via EX-RC1 ▪ Built-in ports: 1 Ethernet, 1 USB host, 1 Mini-B USB device port ▪ Serial and CANbus ports may be added via UAC-CX modules ▪ Fieldbus: CANopen, CAN Layer2, MODBUS, EtherNetIP and more. Implement any serial RS232/485, TCP/IP, or CANbus third-party protocols via Message Composer ▪ Advanced: SNMP Agent/Trap, e-mail, SMS, modems, GPRS/GSM, VNC Client, FTP Server/Client Programming Software All-in-One software for hardware configuration, communications, and HMI /PLC applications, available as a free do

 Open the catalog to page 1
US7-x10-TA30-2

UniStream® Built-in Comparison table System Memory Audio Jack Video/RSTP Support Before You Begin Before installing the device, the user must: ▪ Read and understand this document. ▪ Verify the Kit Contents. Alert Symbols and General Restrictions When any of the following symbols appear, read the associated information carefully. Symbol The identified danger causes physical and property damage. Warning Caution The identified danger could cause physical and property damage. ▪ All examples and diagrams are intended to aid understanding, and do not guarantee operation. Unitronics accepts no responsibility...

 Open the catalog to page 2
US7-x10-TA30-3

UniStream® Built-in Kit Contents ▪ 1 PLC+HMI controller ▪ 1 power terminal block ▪ 2 I/O terminal blocks (provided only with models comprising built-in I/Os) ▪ 1 panel mounting seal ▪ 2 panel supports (US7/US10 only) Product Diagram Front and Rear View 1 Screen Protection A plastic sheet attached to the screen for protection. Remove it during installation of the HMI Panel. Battery Cover The battery is supplied with the unit, but must be installed by the user. Power Supply Input Connection point for the controller power source. microSD Slot Supports standard microSD cards. Provides the interface...

 Open the catalog to page 3
US7-x10-TA30-4

UniStream® Built-in Installation Space Considerations Allocate space for: ▪ the controller ▪ any modules that will be installed ▪ access to ports, jacks, and the microSD card slot For exact dimensions, please refer to the Mechanical Dimensions shown below. Mechanical Dimensions

 Open the catalog to page 4
US7-x10-TA30-5

UniStream® Built-in

 Open the catalog to page 5
US7-x10-TA30-6

UniStream® Built-in Allow space for modules to be snapped onto the back of the controller, if required by your application. Modules are available by separate order.

 Open the catalog to page 6
US7-x10-TA30-7

UniStream® Built-in Panel Mounting NOTE ▪ Mounting panel thickness must be less or equal to 5mm (0.2”). ▪ Ensure that the space considerations are met. 1. Prepare a panel cut-out according to the dimensions as shown in the previous section. 2. Slide the controller into the cut-out, ensuring that the Panel Mounting Seal is in place as shown below. 3. Push the mounting brackets into their slots on the sides of the panel as shown below. 4. Tighten the bracket screws against the panel. Hold the brackets securely against the unit while tightening the screws. The torque required is 0.35 N·m (3.1 in-lb)....

 Open the catalog to page 7
US7-x10-TA30-8

UniStream® Built-in

 Open the catalog to page 8
US7-x10-TA30-9

UniStream® Built-in Battery: Back-up, First Use, Installation, and Replacement Back-up In order to preserve back-up values for RTC and system data in the event of power off, the battery must be connected. First Use The battery is protected by a removable cover on the side of the controller. The battery is supplied installed inside the unit, with a plastic tab preventing contact which must be removed by the user. Battery Installation and Replacement ▪ Use proper precautions to prevent Electro-Static Discharge (ESD) while servicing the battery. Caution ▪ To preserve back-up values for RTC and system...

 Open the catalog to page 9
US7-x10-TA30-10

UniStream® Built-in Wiring ▪ This equipment is designed to operate only at SELV/PELV/Class 2/Limited Power environments. ▪ All power supplies in the system must include double insulation. Power supply outputs must be rated as SELV/PELV/Class 2/Limited Power. ▪ Do not connect either the ‘Neutral’ or ‘Line’ signal of the 110/220VAC to device’s 0V point. ▪ Do not touch live wires. ▪ All wiring activities should be performed while power is OFF. ▪ Use over-current protection, such as a fuse or circuit breaker, to avoid excessive currents into the power supply connection point. ▪ Unused points should...

 Open the catalog to page 10
US7-x10-TA30-11

UniStream® Built-in ▪ Earthing the cables' shield: ➢ Keep shield connections as short as possible. Connect the cable shield to the earth of the system (preferably to the metal cabinet chassis). Note that the shield must be connected only at one end of the cable; it is recommended to earth the shield at the PLC-side. Ensure shield continuity when extending shielded cables. For detailed information, refer to the document System Wiring Guidelines, located in the Technical Library in the Unitronics’ website. Wiring the Power Supply The controller requires an external power supply. ▪ In the event...

 Open the catalog to page 11
US7-x10-TA30-12

UniStream® Built-in The IOs for these models are arranged in three groups of fifteen points each, as shown in the figures to the right. Top groups Input connection points Bottom group Output connection points The function of certain I/Os may be adapted via wiring and software settings.

 Open the catalog to page 12

All Unitronics catalogs and technical brochures

  1. US7-x10-RA28

    18  Pages

  2. US7-x5-RA28

    18  Pages

  3. US7-x10-T42

    18  Pages

  4. US7-x5-T42

    10  Pages

  5. US7-x10-R38

    10  Pages

  6. US7-x5-R38

    10  Pages

  7. US7-x10-T24

    9  Pages

  8. US7-x5-T24

    9  Pages

  9. US7-x10-TR22

    9  Pages

  10. US7-x5-TR22

    9  Pages

  11. US7-x10-B1

    9  Pages

  12. US7-x5-B1

    9  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.