Overview: The 400 Series includes pressure, vacuum, differential pressure, and temperature switches designed for applications needing single or multiple switching capabilities. These are used in industries like gas production, energy generation, and water treatment for alarm and shutdown functions, high/low limits, or level staging.
Features: The switches provide 1, 2, or 3 switch outputs, an epoxy-coated enclosure meeting type 4X standards, and various pressure sensors and materials. They are FM approved with adjustable ranges for vacuum, pressure, differential pressure, and temperature.
Specifications: Operating within -40 to 160°F, the switches have set point shifts typically less than 1% for a 50°F change and repeatability within ±1% to ±3% of full scale range. Enclosures are die-cast aluminum, epoxy powder-coated, meeting type 4X requirements. Electrical ratings include 15 A at 125/250/480 VAC resistive, with limited DC capabilities.
Approvals: The 400 Series is UL listed, cUL certified, FM approved, and compliant with European ATEX and Low Voltage Directives, with certifications for Russia and Brazil.
Model Specifications: Detailed specifications for models include adjustable set point ranges, deadband, over range pressure, and proof pressure. Models offer different materials and connection types, like stainless steel and brass.
Specifications and Options: Options for pressure and temperature sensors include materials and configurations. Optional materials for WC sensors include aluminum and 316L stainless steel with various diaphragm and O-ring combinations. Union connectors and thermowells are available in brass and stainless steel for bulb & capillary switches.
Ordering Options: Instructions emphasize consulting the factory for specific configurations, especially for DC capabilities and models without switch options.
Dimensional Drawings: Dimensions for models are provided in inches and millimeters, including pressure, differential pressure, and temperature sensors.
Recommended Practices and Warnings: United Electric Controls Company advises considering pressure and temperature limits to avoid damage. Backup units are recommended for critical applications. Installation should avoid shock, vibration, and temperature fluctuations. Regular maintenance and monitoring are advised.
Warranty and Liability: A limited warranty covers defects in material and workmanship for 24 months from manufacture. It disclaims other warranties and limits liability to repair or replacement of defective products, excluding special, indirect, or consequential damages.
For more information, including dimensional drawings and sales office locations, visit the company's website at www.ueonline.com.
See more

Catalog excerpts

400 series-1

PRESSURE, VACUUM, DIFFERENTIAL PRESSURE AND TEMPERATURE SWITCHES FEATURES • 1, 2 & 3 switch outputs • Epoxy-coated enclosure designed to meet enclosure type 4X • Wide variety of pressure sensors and materials • Setting via reference dial or hex screw adjustment • FM approved • Adjustable Ranges: "WC ranges: 300 "wc vacuum to 250 “wc pressure (-746,7 to 622,3 mbar) Pressure: 30 “Hg Vac to 6000 psi (-1,0 to 413,7 bar) Differential Pressure: 1"wcd to 200 psid (2.5 mbar to 13,8 bar) Temperature: -125 to 650 °F (-87.2 to 343.3 °C) LEADERS IN SAFETY, ALARM & SHUTDOWN

 Open the catalog to page 1
400 series-2

The 400 Series is a versatile family of vacuum, pressure, differential pressureandtemperatureswitchesforapplicationsthatrequiresingle or multiple switching capabilities. Dual and triple switch versions provide multi-output for alarm and shutdown, pre-alarm and alarm, high/low limit or level staging functions. UL listed and cUL certified. FM approved. CE compliant to low voltage directive and pressure equipment directive. A wide variety of microswitch and process connection options, along with a weather-tight enclosure, make the 400 Series an ideal choice for most ordinary location applications....

 Open the catalog to page 2
400 series-3

specifications AMBIENT TEMPERATURE LIMITS -40 to 160°F (-40 to 71°C); set point typically shifts less than 1% of range for a 50°F (28°C) ambient temperature change Temperature models: ± 2% of full scale range Pressure: models 126-376, 520-535, 540-547, 570-572, S126B-S164B: ± 2% of full scale range; models 440-457, 550-559: ± 1% of full scale range; models 610-614: ± 3% of full scale range Set point repeats after 15 G, 10 millisecond duration Set point repeats after 2.5 G, 5-500 Hz Die cast aluminum, epoxy powder coated, gasketed, captive cover screws ENCLOSURE CLASSIFICATION Designed to meet...

 Open the catalog to page 3
400 series-4

approvals UNITED STATES AND CANADA Type 400 & 402 UL Listed, cUL Certified Pressure: UL 508; CSA C22.2 No. 14, file # E42272 Temperature: UL 873; CSA C22.2 No. 24, file # E10667 Type 403 UL Recognized, cUL Recognized Pressure: UL 508; CSA C22.2 No. 14, file # E42272 Temperature: UL 873; CSA C22.2 No. 24, file # E10667 INMETRO (OPTIONAL – code M391) Ex ia IIC T6 Ga -50°C ≤ Ta ≤ +60°C UL-BR 15.0169X ABNT NBR IEC 60079-0 ABNT NBR IEC 60079-11 ABNT NBR IEC 60079-26 All Types FM Approved Pressure: Class 3510 Temperature: Class 3545 EUROPE ATEX Directive (2014/34/EU) II 1 G Ex ia IIC T6 Ga (OPTIONAL...

 Open the catalog to page 4
400 series-5

pressure model chart Type J400, single switch output with internal hex screw adjustment Type J402, dual switch output with internal hex screw adjustment Type J403, triple switch output with internal hex screw adjustment Model Adjustable Set Point Range Low end of range on fall; High end of range on rise Deadband doubles for 2 and 3 switch types Over Range Pressure* Proof Pressure** Buna-N diaphragm and O-Ring with epoxy coated aluminum 1/2” NPT (female) pressure connection, large 0.72” orifice for clean-out purposes. Other wetted materials available, see pg. 12; Option M449 recommended 520† 521†...

 Open the catalog to page 5
400 series-6

pressure model chart Type J400, single switch output with internal hex screw adjustment Type J402, dual switch output with internal hex screw adjustment Type J403, triple switch output with internal hex screw adjustment Adjustable Set Point Range Low end of range on fall; High end of range on rise Deadband doubles for 2 and 3 switch types Over Range Pressure* (unless noted) (unless noted) Proof Pressure** (unless noted) 303 stainless steel piston with Buna-N O-Ring and 303 stainless steel 1/4” NPT (female) pressure connection (not recommended for gas service since drying of the O-Ring seal can...

 Open the catalog to page 6
400 series-7

pressure model chart Type H400, single switch output with internal adjustment via reference dial Type H402, dual switch output with internal adjustment via reference dial Type H403, triple switch output with internal adjustment via reference dial Model Adjustable Set Point Range Proof Pressure** High end of range on rise Low end of range on fall; Deadband doubles for 2 and 3 switch types Scale Division (unless noted) (unless noted) (unless noted) (unless noted) (unless noted) Welded 316L stainless steel bellows and 1/2” NPT (female) pressure connection S126B S134B S137B† S144B S146B S156B S164B...

 Open the catalog to page 7
400 series-8

pressure model chart Type H400, single switch output with internal adjustment via reference dial Type H402, dual switch output with internal adjustment via reference dial Type H403, triple switch output with internal adjustment via reference dial Adjustable Set Point Range Proof Pressure** Scale Division Low end of range on fall; High end of range on rise Deadband doubles for 2 and 3 switch types (unless noted) (unless noted) (unless noted) (unless noted) (unless noted) Teflon® diaphragm and Viton® O-Ring with 316L stainless steel 1/4” NPT (female) pressure connection and cap 550†† 552†† 553††...

 Open the catalog to page 8
400 series-9

differential pressure model chart Type J400K, single switch output with internal hex screw adjustment Type J402K, dual switch output with internal hex screw adjustment Model Adjustable Set Point Range Low end of range on fall; High end of range on rise Working Pressure*** Proof Pressure** Deadband doubles for 2 switch types (unless noted) (unless noted) (unless noted) (unless noted) Buna-N diaphragms and o-ring with epoxy coated aluminum 1/8” NPT (female) pressure connections (J402K only); Option M449 recommended 540† 541† 542† 543† 544† 545† 546† 547† Teflon® and Buna-N diaphragms, Buna-N O-Ring...

 Open the catalog to page 9
400 series-10

temperature model chart Type B400, single switch output, immersion stem, internal adjustment via reference dial Type B402, dual switch output, immersion stem, internal adjustment via reference dial Type B403, triple switch output, immersion stem, internal adjustment via reference dial Type C400, single switch output, immersion stem, internal hex screw adjustment Type C402, dual switch output, immersion stem, internal hex screw adjustment Type C403, triple switch output, immersion stem, internal hex screw adjustment Type E400, single switch output, bulb & capillary***, internal adjustment via...

 Open the catalog to page 10

All United Electric Controls catalogs and technical brochures

  1. 55 Series

    8  Pages

  2. J6 Series

    8  Pages

  3. 24 Series

    8  Pages

  4. J21K Series

    8  Pages

  5. 800 series

    8  Pages

  6. 117 Series

    12  Pages

  7. Sensor Box

    8  Pages

  8. 120 Series

    28  Pages

  9. 100 Series

    15  Pages

  10. 10 Series

    8  Pages

  11. One Series

    16  Pages

  12. 12 Series

    16  Pages

  13. AST Catalog

    12  Pages

  14. PSI Catalog

    8  Pages

  15. 54 Series

    12  Pages

  16. J40 Series

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.