Overview: The 12 Series switches are engineered for hazardous environments, featuring 316 stainless steel construction, hermetically sealed micro-switches, and vibration resistance due to the Belleville spring assembly. They are globally applicable with UL, cUL, ATEX, and IECEx approvals.
Key Features: These switches comply with ANSI/ISA 12.27.01 and NEC 501.17, offer optional materials like Hastelloy® and Monel® for corrosive media, and include a snap-acting Belleville spring for durability. They come with 72" lead wires, a 3-year warranty, and mounting brackets for retrofitting.
Specifications: Operating temperatures range from -58 to 176°F, with media temperatures varying by sensor type. Set point accuracy is ±1% for temperature models and ±1.5% for some pressure models. The enclosure is 316 stainless steel, certified to Type 4X and IP66, with SPDT and DPDT switch output options.
Applications: Suitable for offshore platforms, rotating equipment, chemical plants, and refineries, especially in space-constrained environments.
Compliance and Certifications: The 12 Series meets UL, ATEX, IECEx, and PED standards, complying with directives like the Low Voltage Directive and Pressure Equipment Directive.
Model Chart: Detailed specifications for sensor types include adjustable set point ranges, deadband, over-range, and proof pressure values, ensuring durability under various conditions.
Procedures and Recommendations: Avoid metallic diaphragms in high-pressure shock environments. Over Range Pressure is the maximum continuous pressure without damage, while Proof Pressure is the maximum occasional pressure without permanent damage.
Ordering Information: Instructions for constructing part numbers include series designation, housing material, electrical rating, and more. Options include factory-set switches and compliance with safety standards.
Accessories and Optional Features: Available accessories include mounting bracket kits, junction boxes, and thermowells. Optional materials for corrosive media include Hastelloy and Monel diaphragms.
Dimensional Drawings: Available online, these drawings provide detailed measurements for various models and optional mounting kits.
Product Options: Customization options include mounting brackets, cover locks, junction boxes, and more, with specific compliance notes.
Alternative Products: Alternatives like the Vanguard Gas Detector and One Series Safety Transmitter offer features such as WirelessHART communication and SIL2 IEC 61508 certification.
Recommended Practices and Warnings: Recommendations include adhering to pressure and temperature limits, using backup units, proper installation, and regular maintenance.
Limited Warranty: A 36-month warranty covers defects in material and workmanship, excluding tampering or misuse.
Limitation of Liability: Liability is limited to repair and replacement, with no responsibility for indirect damages.
Additional Information: Specifications may change without notice. Visit www.ueonline.com for sales office information.
See more

Catalog excerpts

12 Series-1

PRESSURE, VACUUM, DIFFERENTIAL PRESSURE, AND TEMPERATURE SWITCHES PRESSURE, DIFFERENTIAL PRESSURE, AND TEMPERATURE SWITCHES DUAL SEAL CERTIFIED • 316 Stainless Steel Construction withstands the harshest environments • Hermetically Sealed Micro-switch • Vibration Resistant Belleville provides set point stability • UL, cUL, ATEX and IECEx approved • Dual Seal provides process sealing between electrical system and combustible process fluids LEADERS IN SAFETY, ALARM & SHUTDOWN

 Open the catalog to page 1
12 Series-2

12 Series hazardous location switches are ideal for operation in tough applications where space is at a premium. A snap-action Belleville spring assembly is used in most models to provide vibration resistance and prolonged switch life. The 316 stainless steel enclosure and hermetically sealed switch provide rugged protection from the environment. Approved for use in hazardous locations worldwide, the 12 Series is installed within applications ranging from offshore oil rigs to rotating equipment, and more. • UL, cUL, ATEX and IECEx approved for Div. 1 or Zone 1 hazardous locations; CE compliant...

 Open the catalog to page 2
12 Series-3

WORLDWIDE COMPLIANCE Quadruple approvals (UL, cUL, ATEX and IECEx) mean the 12 Series meets the demanding requirements of critical applications within hazardous locations. Additionally, the 12 Series complies with ANSI/ISA 12.27.01, "secondary seal requirements for process sealing between electrical systems and flammable or combustible process fluids," and NEC 501.17, "process sealing." It can be used in a variety of applications where space is at a premium. Metal wetted parts comply with NACE MR0175 and the 316 stainless steel, type 4X enclosure rating assure long-term performance in the harshest...

 Open the catalog to page 3
12 Series-4

SPECIFICATIONS OPERATING AMBIENT TEMPERATURE MEDIA TEMPERATURE -58 to 176°F (-50 to 80°C); Sensor Type K: 0°F to 160°F (-18°C to 71°C). Set point shifts less than 1% of range for a 50°F (28°C) ambient temperature change. Slight ambient effects for 25-50’ extra capillary length on temperature switch models, consult factory. Pressure models: Sensor types 2, 7, 9: -50 to 400°F (-45 to 204°C) Sensor types 3, 4, 8: -20 to 200°F (-28 to 93°C) Sensor types 5, 6: 0 to 320°F (-18 to 160°C) Sensor type P, W: 0 to 200°F (-18 to 93°C); 20 to 250°F (-7 to 121°C) for optional Viton sensor Differential pressure...

 Open the catalog to page 4
12 Series-5

Bulb and capillary: Non-toxic oil fill; 6 feet 304 stainless steel. Optional lengths available Immersion Stem: 316 stainless steel TEMPERATURE DEADBAND Typically 2% of range under laboratory conditions (70°F ambient circulating bath at a rate of 1/2°F per minute change) PRESSURE CONNECTION 1/2" NPT (female) or 1/4" NPT (female). Differential pressure: 1/8" NPT (female) Optional pressure connection materials available, see page 12. Pressure: May be pipe mounted or bracket mounted using kit 62169-13 Differential Pressure: Should be mounted using 2 mounting holes on attached mounting bracket Temperature:...

 Open the catalog to page 5
12 Series-6

MODEL CHART Model Adjustable Set Point Range Lower end of range on fall; High end of range on rise Over Range Pressure* Proof Pressure** Sensor Type 2, 316 stainless steel 1/2” NPT (female) pressure connection and welded diaphragm, 23/32” orifice for clean out purposes. High proof pressure. Not recommended for high cycling applications. Belleville actuation. (NACE MR0175 compliant with M401 option) psi A B C D E F G Sensor Type 3, 316L stainless steel 1/2” NPT (female) pressure connection, Teflon® coated Polyimide (Kapton®) diaphragm, Buna N O-ring, 1/2” orifice for clean out purposes. Belleville...

 Open the catalog to page 6
12 Series-7

Adjustable Set Point Range Over Range Pressure* Lower end of range on fall; High end of range on rise Proof Pressure** Sensor Type 5, 316L stainless steel 1/2” NPT (female) pressure connection and diaphragm, Viton® O-ring, 1/2” orifice for clean out purposes. Belleville actuation. (NACE MR0175 compliant with M401 option) Sensor Type 6, 316L stainless steel 1/4” NPT (female) pressure connection and diaphragm, Viton® O-ring, 1/8” orifice. Belleville actuation. (NACE MR0175 compliant with M401 option) psi A B C D E F G H Sensor Type 7, 1/2” 316L stainless steel NPT (female) pressure connection and...

 Open the catalog to page 7
12 Series-8

MODEL CHART Model Adjustable Set Point Range Over Range Pressure* Lower end of range on fall; High end of range on rise Proof Pressure** Sensor Type 9, 316L stainless steel 1/2” NPT (female) pressure connection and welded diaphragm. Large 23/32” orifice for clean-out purposes. Non-Belleville actuation. (NACE MR0175 compliant with M401 option) psi A B C mbar (unless noted) Sensor Type P, 316 stainless steel piston and Buna N O-Ring with 316 stainless steel 1/4" NPT (female) pressure connection. Non-Belleville actuation. (NACE MR0175 compliant with M401 option) psi 0 1 2 3 4 Sensor Type P, 316...

 Open the catalog to page 8
12 Series-9

DIFFERENTIAL PRESSURE MODEL CHART Model Adjustable Set Point Range Working Pressure Range*** Lower end of range on fall; High end of range on rise Proof Pressure** Sensor Type K, Buna N diaphragm and sealing diaphragms with epoxy coated aluminum housing and 1/8” NPT (female) pressure connections. Non-Belleville actuation. 303/304 stainless steel mounting bracket attached. SPDT Switch (single pole double throw)‡ "wcd mbar "wc mbar Sensor Type K, Buna N diaphragm and sealing diaphragms with epoxy coated aluminum housing and 1/8” NPT (female) pressure connections. Non-Belleville actuation. 303/304...

 Open the catalog to page 9
12 Series-10

HOW TO ORDER Select letter or number "codes" to construct part number Part # Housing Electrical Switch Electrical Sensor Material Rating Output Conduit Type ORDERING CODE SERIES 12 DESIGNATION 12 Designation for 12 series product line HOUSING MATERIAL S 316 Stainless Steel ELECTRICAL RATING* L 1 amp H 5 amp SWITCH OUTPUT S SPDT D DPDT. Available for pressure models only. ELECTRICAL CONDUIT N 1/2" NPT male M M20 metric thread SENSOR TYPE (Belleville actuated unless noted) 2 Welded 316 stainless steel diaphragm, 1/2” NPT (female) pressure connection 3 Teflon® coated Polyimide (Kapton®) diaphragm,...

 Open the catalog to page 10

All United Electric Controls catalogs and technical brochures

  1. 55 Series

    8  Pages

  2. J6 Series

    8  Pages

  3. 24 Series

    8  Pages

  4. J21K Series

    8  Pages

  5. 800 series

    8  Pages

  6. 400 series

    16  Pages

  7. 117 Series

    12  Pages

  8. Sensor Box

    8  Pages

  9. 120 Series

    28  Pages

  10. 100 Series

    15  Pages

  11. 10 Series

    8  Pages

  12. One Series

    16  Pages

  13. AST Catalog

    12  Pages

  14. PSI Catalog

    8  Pages

  15. 54 Series

    12  Pages

  16. J40 Series

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.