Carbonate ion Chloride ion Sulphate ion Thiocyanate ion Sulphide ion Higher readings are given Higher readings are given Lower readings are given Higher readings are given Higher readings are given Uniphos Detector Tube Instruction Sheet Direct Reading Length of Stain Type Before using this product, carefully read this instruction sheet and strictly follow the recommended instructions. The Uniphos Cyanide ion Detector tube provides a rapid, fully quantitative analysis of cyanide ion concentration in water. The tube requires no pump because the inherent capillary action of water through the support material provides the driving force for the sample to rise. 5. If stain exceeds the highest calibration mark dilute the sample with pure cyanide ion free water and re-test using a fresh tube. The true concentration is to be obtained by multiplying the tube reading by the dilution factor. 6. Check for possible cross-sensitivities. If tailing occurs read at the midpoint of the taper. It is advisable to take the reading within a few minutes of sampling. If necessary mark the end of stain if it is to be read later. Temperature - Not necessary between 0 - 40"C (32 - 104"F). Higher readings are given No 1. The process of breaking the tube ends can generate flying glass bits and leave the tube with sharp edges. Use eye and hand protection while breaking the tube ends. 2. Keep tubes out of reach of unauthorized persons, especially children. 3. Dispose of used tubes according to local regulations. As we are continuously working on the improvement of products, we reserve the right to change the specifications without any prior notice. It is entirely the responsibility of the user of the device to see that the device is operated, and maintained in strict accordance with the manufacturer's instructions provided with the device. It is also the sole responsibility of the user to ensure that the tubes are not used beyond their expiration date. The manufacturer and manufacturer's distributors are not otherwise liable for any incorrect measurement and its consequences or any damages resulting from user's negligence or otherwise. 1. Take sample water into a clean beaker of approximately 100 ml capacity. 2. Break both ends of the tube using the ceramic tip breaker supplied with each box of tubes. 3. Immerse one end of the tube into the sample water so that the indicating ‘arrow mark' points upwards (Fig-1). Due to the capillary action the sample water starts rising through the sensing reagent column. If the sample water contains the cyanide ion, the off white sensing reagent in the tube turns to gray/blue color. 4. When the sample water rises upto the upper end plug remove the tube from the beaker and read the concentration at the interface of the stained to unstained reagent. Manufactured By: Uniphos Envirotronic Pvt. Ltd.(100% EOU) Nahuli (PO), Umbergaon (Tal.) Valsad (Dist), Gujarat, India - 396108
Open the catalog to page 11 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
2 Pages
4 Pages
3 Pages
6 Pages
6 Pages