DCY- 4M

DCY- 4M

Product catalog summary
Introduction: The Uniphos Cyanide Ion Detector Tube is designed for rapid and quantitative analysis of cyanide ion concentration in water without the need for a pump, utilizing capillary action.
Specifications:
  • Measurement Range: 50 – 500 ppm
  • Sampling Time: 10 minutes
  • Color Change: Off white to Gray/blue
  • Sample Water pH Range: 4 - 12
  • Storage Condition: Below 10˚C (50˚F)
  • Calibration Method: Sodium cyanide standard solution at 20˚C
  • Active Reagents: Cupric sulphate and o-toluidine
Measurement Procedure:
  1. Collect sample water in a 100 ml beaker.
  2. Break both ends of the tube using the provided ceramic tip breaker.
  3. Immerse the tube in the sample with the arrow mark pointing upwards.
  4. Read the concentration at the interface of stained and unstained reagent once the water reaches the upper end plug.
  5. If the stain exceeds the highest calibration mark, dilute the sample and retest.
  6. Check for cross-sensitivities.
Notes:
  • Readings should be taken promptly. Mark the stain end if reading later.
Correction for Temperature: No correction needed between 0 - 40˚C (32 - 104˚F).
Possible Interferences:
  • Carbonate ion (1700 ppm): No interference, higher readings.
  • Chloride ion (100 ppm): No interference, higher readings.
  • Sulphate ion (2700 ppm): No interference, lower readings.
  • Thiocyanate ion (100 ppm): Higher readings.
  • Sulphide ion (500 ppm): No interference, higher readings.
Caution:
  • Use eye and hand protection when breaking tube ends.
  • Keep tubes away from unauthorized persons and children.
  • Dispose of used tubes according to local regulations.
Important: Specifications may change without notice due to product improvements.
User Responsibility: Users must operate and maintain the device according to instructions and ensure tubes are not used past expiration. The manufacturer is not liable for incorrect measurements or damages from user negligence.
See more

Catalog excerpts

DCY- 4M-1

Carbonate ion Chloride ion Sulphate ion Thiocyanate ion Sulphide ion Higher readings are given Higher readings are given Lower readings are given Higher readings are given Higher readings are given Uniphos Detector Tube Instruction Sheet Direct Reading Length of Stain Type Before using this product, carefully read this instruction sheet and strictly follow the recommended instructions. The Uniphos Cyanide ion Detector tube provides a rapid, fully quantitative analysis of cyanide ion concentration in water. The tube requires no pump because the inherent capillary action of water through the support material provides the driving force for the sample to rise. 5. If stain exceeds the highest calibration mark dilute the sample with pure cyanide ion free water and re-test using a fresh tube. The true concentration is to be obtained by multiplying the tube reading by the dilution factor. 6. Check for possible cross-sensitivities. If tailing occurs read at the midpoint of the taper. It is advisable to take the reading within a few minutes of sampling. If necessary mark the end of stain if it is to be read later. Temperature - Not necessary between 0 - 40"C (32 - 104"F). Higher readings are given No 1. The process of breaking the tube ends can generate flying glass bits and leave the tube with sharp edges. Use eye and hand protection while breaking the tube ends. 2. Keep tubes out of reach of unauthorized persons, especially children. 3. Dispose of used tubes according to local regulations. As we are continuously working on the improvement of products, we reserve the right to change the specifications without any prior notice. It is entirely the responsibility of the user of the device to see that the device is operated, and maintained in strict accordance with the manufacturer's instructions provided with the device. It is also the sole responsibility of the user to ensure that the tubes are not used beyond their expiration date. The manufacturer and manufacturer's distributors are not otherwise liable for any incorrect measurement and its consequences or any damages resulting from user's negligence or otherwise. 1. Take sample water into a clean beaker of approximately 100 ml capacity. 2. Break both ends of the tube using the ceramic tip breaker supplied with each box of tubes. 3. Immerse one end of the tube into the sample water so that the indicating ‘arrow mark' points upwards (Fig-1). Due to the capillary action the sample water starts rising through the sensing reagent column. If the sample water contains the cyanide ion, the off white sensing reagent in the tube turns to gray/blue color. 4. When the sample water rises upto the upper end plug remove the tube from the beaker and read the concentration at the interface of the stained to unstained reagent. Manufactured By: Uniphos Envirotronic Pvt. Ltd.(100% EOU) Nahuli (PO), Umbergaon (Tal.) Valsad (Dist), Gujarat, India - 396108

 Open the catalog to page 1

All Uniphos Envirotronic Pvt. Ltd. catalogs and technical brochures

  1. SCO- 6M

    1  Page

  2. SCL-3

    1  Page

  3. D7086765

    1  Page

  4. D5019708/709

    1  Page

  5. D5085848

    1  Page

  6. D5085854

    2  Pages

  7. D5085843

    1  Page

  8. D5085816

    1  Page

  9. D5019704

    1  Page

  10. D7086882

    1  Page

  11. D5085771

    2  Pages

  12. 10017882

    1  Page

  13. Uniphos 351M

    1  Page

  14. SXY- 4

    1  Page

  15. SNO-2M

    1  Page

  16. SEA-7

    1  Page

  17. ASP-11

    1  Page

  18. ASP-40

    2  Pages

  19. Kwiksense Pro

    6  Pages

  20. KwikSense

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.