Application
The Action Detector Tube is designed for a quick orientative check of ambient atmosphere for hazardous concentrations of vapors of easily oxidizable halogenated hydrocarbons.
Detector Tube Sampling Pump
Compatible with KWIK DRAW (formerly MSA AUER) Gas-Tester® IIH, Gas-Tester® I / ThumbPump™-Sampler, Toximeter® II, Uniphos Kwik-Draw™-Pump, or other suitable detector tube pumps. Users should follow the respective instructions for use.
Measuring Range
The detector tube has two marks indicating the following concentrations: Mark 1: 50 ppm trichloroethylene at n=2 (2 strokes); Mark 2: 150 ppm trichloroethylene at n=2 (2 strokes).
Chemical Reaction and Color Change
The oxidative decomposition of halogenated hydrocarbons occurs in the conversation layer by a chromate/sulfuric acid reagent, forming chlorine or bromine. This leads to the oxidation of an aromatic amine by chlorine or bromine in the indicating layer, resulting in a color change from white to orange.
Ambient Conditions During Sampling
The detector tubes can be used without compensation of the reading between 5 °C and 35 °C (40 °F and 95 °F) and between 10% rh [0.7 g/m3 at 5 °C (40 °F)] and 90% rh [36 g/m3 at 35 °C (95 °F)].
Interferences and Cross Sensitivities
  • No interference from hydrogen, methane, ethane, carbon monoxide, carbon dioxide, propane, butanes, chloromethane, dichloromethane, carbon tetrachloride, bromomethane, fluorinated methanes, fluorinated ethanes up to 5,000 ppm, ammonia, sulfur dioxide, hydrogen cyanide up to 100 ppm.
  • Higher saturated hydrocarbons (e.g., hexanes), olefinic hydrocarbons (e.g., ethylene), aromatic hydrocarbons (e.g., benzene), hydrogen sulfide, carbon disulfide, alcohols, ketones, ethers, esters produce no indication. In the presence of these substances, part of the conversation layer will be consumed, potentially leading to a lower indication of halogenated hydrocarbons than actually present. High concentrations of these substances may discolor the conversation layer from brown to greenish, and the detector tube should not be used in such cases.
  • Halogens (chlorine, bromine), hydrogen chloride, phosgene, nitric oxide, nitrogen dioxide are indicated, with varying sensitivity.
See more

Catalog excerpts

D5085771-1

Information Data Sheet Action Detector Tube Quick orientative check of ambient atmosphere for hazardous concentrations of vapors of several easiy oxidizable halogenated hydrocarbons. KWIK DRAW(formerly MSA AUER) Gas-Tester® IIH, Gas-Tester® I / ThumbPump™-Sampler, Toximeter® II, Uniphos Kwik-Draw™-Pump or other suitable detector tubes pumps. Observe respective instructions for use. The action detector tube has two marks conforming the following concentrations: Mark 1: 50 ppm trichloroethylene at n=2 (2 strokes). Mark 2: 150 ppm trichloroethylene at n=2 (2 strokes). Oxidative decomposition of halogenated hydrocarbons in the conversation layer by a chromate/sulfuric acid reagent, forming chlorine or bromine. Oxidation of an aromatic amine by chlorine resp. bromine in the indicating layer. Color change: white ^ orange 5. Ambient Conditions During Sampling Detector tubes can be used without compensation of the reading between 5 °C and 35 °C (40 °F and 95 °F) and between 10% rh [0.7 g/m3 at 5 °C (40 °F)] and 90% rh [36 g/m3 at 35 °C (95 °F)]. - hydrogen, methane, ethane, carbon monoxide, carbon dioxide. - propane, butanes, chloromethane, dichloromethane, carbon tetrachloride, bromomethane, fluorinated methanes, fluorinated ethanes up to 5,000 ppm. - ammonia, sulfur dioxide, hydrogen cyanide up to 100 ppm. Marketing Office: Uniphos Envirotronic Pvt. Ltd Readymoney Terrace, 167, Dr. Annie Besant Road, Worli, Dist: Valsad, Gujarat, India Tel. : +91(260) 2730156 / 57 / 58 Fax : +91(260) 2730160

 Open the catalog to page 1
D5085771-2

Higher saturated hydrocarbons (e.g. hexanes), olefinic hydrocarbons (e.g. ethylene), aromatic hydrocarbons (e.g. benzene), hydorgen sulfide, carbon disulfide, alcohols, ketones, ethers, esters produce no indication. Inthe presence of these substances part of conversation layer will be consumed. Indication of halogenated hydrocarbons then may be lower than actually present. High concentrations of those accompanying substances discolor conversation layer from brown to greenish. Do not use detector tube in this case. halogens (chlorine, bromine), hydrogen chloride, phosgene, nitric oxide, nitrogen...

 Open the catalog to page 2

All Uniphos Envirotronic Pvt. Ltd. catalogs and technical brochures

  1. SCO- 6M

    1  Page

  2. SCL-3

    1  Page

  3. D7086765

    1  Page

  4. D5019708/709

    1  Page

  5. D5085848

    1  Page

  6. D5085854

    2  Pages

  7. D5085843

    1  Page

  8. D5085816

    1  Page

  9. D5019704

    1  Page

  10. D7086882

    1  Page

  11. 10017882

    1  Page

  12. Uniphos 351M

    1  Page

  13. DCY- 4M

    1  Page

  14. SXY- 4

    1  Page

  15. SNO-2M

    1  Page

  16. SEA-7

    1  Page

  17. ASP-11

    1  Page

  18. ASP-40

    2  Pages

  19. Kwiksense Pro

    6  Pages

  20. KwikSense

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.