Catalog excerpts
HX-EP SERIES DIGITAL OUTPUT Utilizing an incremental encoder as the sensor, the UniMeasure HX-EP Series position transducer provides a two channel square wave current sinking output signal in quadrature. The standard output is a single-ended TTL compatible square. The resolution values shown in the specifications table indicate resolution for times 1 counting mode where a count is registered for one up transition in channel A. With interface electronics capable of times 2 or times 4 counting mode, a true resolutional increase of 2 or 4 may be obtained. For example, the HX-EP-50 has a resolution of approximately .004" per count in times 1 counting mode whereas the resolution is approximately .001" per count in times 4 counting mode. The actual resolution of a HX-EP transducer differs from unit to unit because of tolerances associated with the wire rope diameter and the capstan upon which the wire rope winds. The nylon jacketed wire rope option will have the effect of slightly reducing the resolution. Linearity and repeatability remain independent of resolution. In applications where the output count is interpreted as a percentage of total travel, resolutional differences from unit to unit are not critical. However, in applications where the digital output is to be interfaced to a digital display to give an output in engineering units, the calibration constant supplied with the transducer may be used to calculate a suitable scale multiplier to produce the correct engineering units. Alternative outputs shown in the Electrical Outputs table below are available to facilitate interfacing to a variety of different types of equipment. ALL RANGES GREATER THAN 100” ELECTRICAL OUTPUT For electrical output description, waveform and wiring, See Page 3. FOOTNOTES TO SPECIFICATIONS 1. Supplemental Data section located at end of HX Series pages. 2. Submersion to 2m (6.5’) maximum depth in fresh water. 3. The resolution shown is a calculated number based upon the capstan diameter, wire rope diameter and line count of the encoding device. The tolerance on the resolution accounts for resolutional differences from unit to unit due to manufacturing tolerances on the capstan and wire rope. In practice, the output count in a given unit of travel is an integer. MODEL NUMBER CONFIGURATION Basic Configuration RANGE Select Measurement Range From S u p p l e m e n t a l D a t a , Ta b l e 12 Table 12 (next page), Insert Corresponding Measurement Range Designator (See Supplemental Data, Table 12) INGRESS PROTECTION ELECTRICAL OUTPUT For Description See TABLE 8 on next page Nylon Jacketed Stainless Steel Ranges to 80” (2m) only. (formerly NJC) WIRE ROPE TENSION WIRE ROPE EXIT DIRECTION Use Number designators shown NOTES FOR OPTION BOXES (NEMA 4): Transducer equipped with body mounted connector and with or without mating connector. Mating connector with electrical cable available separately as part number 10119-xM where ‘x’ is length of electrical cable in meters. IP-68–NEMA 6 CABLE MOUNTED CONNECTOR (NEMA 6): Transducer equipped with bulkhead fitting and length of electrical cable. Remote end of electrical cable may be outfitted with water proof connector. Mating connector with electrical cable available separately as part number 10424-xM where ‘x’ is length of electrical cable in meters. 4175 SW Research Way, Corvallis, Oregon 97333 U.S.A. | Tel
Open the catalog to page 1SUPPLEMENTAL DATA ADDITIONAL OPTIONS Use value from this column to indicate overall measurement range MEASUREMENT RANGE DESIGNATOR STANDARD MEASUREMENT RANGES APPLICABLE SERIES HX-PA HX-PB HX-P420 HX-P510 Check mark indicates available measurement range WIRE ROPE TENSION (NOMINAL) WIRE ROPE DIAMETER TRANSDUCER WEIGHT Product Photo Specifications subject to change without notice 4175 SW Research Way, Corvallis, Oregon 97333 U.S.A. | Tel: 541-757-3158 | Fax: 541-757-0858 | Email: sales@unimeasure.com
Open the catalog to page 2SUPPLEMENTAL DATA ADDITIONAL OPTIONS EP, HX-EP SERIES OPTIONAL ELECTRICAL OUTPUTS OPTION OUTPUT DESCRIPTION WAVEFORM CONNECTOR WIRING OUTPUT STAGE 5 VDC TTL compatible output. Input Voltage: 5 VDC. Current sinking output with 10KΩ internal pullup resistors. Input Voltage: 8 to 28 VDC. 5 VDC Push-Pull Differential Line Drive Push-Pull, current sourcing and current sinking output. Output is compliant with requirements of TIA/EIA-422-B. Input Voltage: 5 VDC input. 8 to 28 VDC Push-Pull Differential Line Drive Push-Pull, current sourcing and current sinking output. Input Voltage: 8 to 28 VDC....
Open the catalog to page 3SUPPLEMENTAL DATA OPTION DESCRIPTIONS OPTION OPTION DESIGNATOR NYLON JACKETED WIRE ROPE RANGES TO 80” ONLY NYLON JACKETED WIRE ROPE RANGES 100" TO 500" ONLY ALTERNATE WIRE ROPE EXIT RANGES TO 80” (2.0 m) DESCRIPTION Replaces standard stainless steel wire rope with Ø.018 nylon jacketed wire rope. This option increases wire rope life dramatically but may increase non-linearity by as much as ±.05% of full scale. Replaces standard stainless steel wire rope with Ø.037 nylon jacketed wire rope. Dimensions in brackets are millimeters ALTERNATE WIRE ROPE EXIT RANGES 100” (2.5 m) and GREATER 1, 2, 3...
Open the catalog to page 4SUPPLEMENTAL DATA DIMENSIONAL INFORMATION HX SERIES – RANGES TO 80” (2 m) HX SERIES – RANGES GREATER THAN 80” (2 m) 1. Transducer mounts with Ø.25 or M6 Socket head cap bolts. Dimensions in brackets are millimeters 1. ransducer mounts with Ø.50 or M12 socket head cap bolts. T 2. Dimension "C" is the cable offset that occurs as the cable is extended from the transducer. For "C" in inches, C = .0016 x E where E = extension in inches. For "C" in millimeters, C = .0016 x E where E = extension in mm. Dimensions in brackets are millimeters 4175 SW Research Way, Corvallis, Oregon 97333 U.S.A. |...
Open the catalog to page 5All UniMeasure catalogs and technical brochures
-
HX-V SERIES
4 Pages
-
HX-VP SERIES
4 Pages
-
HX-P510 SERIES
4 Pages
-
HX-P420 SERIES
4 Pages
-
HX-PB SERIES
4 Pages
-
HX-PA SERIES
4 Pages
-
LX-EP2 SERIES
2 Pages
-
LX-EM SERIES
2 Pages
-
MICRO-P DISPLAY
2 Pages
-
FX-HM SERIES
2 Pages