Ultrasonic Fixed Flow Meter UF 831 Overview
The UF 831 is a high-performance ultrasonic fixed flow meter designed for accurate and reliable flow measurement across various applications. It supports pipe diameters up to 10,000mm and offers advanced functionalities for diverse industrial needs.
Key Specifications
  • Supports up to eight speed chords on a single pipe for optimized accuracy.
  • Offers up to 10 input/output modules, both analogue and digital.
  • Features a graphic screen displaying echo, gain, and quality index.
  • Accuracy up to 0.5% with repeatability up to 0.1%.
  • Automatic zero calibration for enhanced precision.
Advanced Functions
  • Includes a mathematical functions generator and a multi-parameter data logger.
  • Field bus options available: Modbus TCP/Modbus RTU.
Typical Applications
  • Water and wastewater management, including flow measurement and process control.
  • Climate engineering for water metering in air conditioning systems.
  • Handling of chemical products, food, farming products, crude oil, and refined oil products.
  • Energy sector applications, such as hydroelectric power station yield calculations.
Competitive Advantages
  • Supports up to eight measurement points with a single device.
  • Rapid installation with no moving parts, reducing maintenance needs.
  • Adaptable to connect with all Ultraflux probes or existing probes.
Models and Media
  • Available in single pipe and multi-pipe models.
  • Measures various liquids with internal pipe diameters from 8mm to 9,900mm and external diameters up to 10,000mm.
Input/Output Options
  • Field bus option allows up to 5 programmable modules; without it, up to 10 modules.
  • Includes mandatory base modules and optional modules for additional functionalities.
Communication and Display
  • Supports Modbus TCP and Modbus RTU protocols.
  • Features a numeric and graphical backlit LCD screen.
Troubleshooting and Setup
  • Oscilloscope function for troubleshooting with echo display, gain, and quality index.
  • Quick setup via a 7-key touchpad or dedicated software.
Data Storage and Operating System
  • 8MB data logger with time-stamping capabilities for up to 536,886 data items.
  • Compatible with Windows for data transfer and logger operation.
Technical Specifications
  • Accuracy up to 0.5%, repeatability up to 0.1%, and linearity up to 0.1%.
  • Continuous bidirectional measurement with advanced signal analysis.
  • Temporal resolution of 0.1ns and flow calculation every 100ms.
  • Memory capacity for up to 11 configurations.
Additional Features
  • Considers laminar and turbulent transitions with Reynolds number calculations.
  • Flexible probe mounting options in various modes.
See more

Catalog excerpts

Uf 831 - Fixed ultrasonic flow meter for full pipe-1

Uf 831 Full pipe Ult rasonic fixed flow meter media measured liquids models single pipe multi-pipe pipe diameters up to 10 000mm high performance accu r ate advanced functions ›U p to eight speed chords on a single pipe ›A ccurate up to 0.5% › athematical functions M generator ›U p to 10 input/output modules (analogue, digital) › epeatability up to 0.1% R › ulti-parameter M data logger › utomatic zero A calibration ›G raphic screen › ield bus option: F Modbus TCP/Modbus RTU ›E cho, gain and quality index displayed COMPETITIVE › p to eight measurement U points with a single device › Rapid installation › No moving parts, no mechanical wear: little or no maintenance required adaptable › Connection of all Ultraflux probes or probes already installed* typical Applications UF 831 M1 M2 M3 M4 M5 M6 A1 M7 M8 B1 M9 M10 C1 D1 D2 UF831 LEXAN INF V3V7V11V15C Waste water and drinking water: Flow measurement and metering, process control, system supervision Waste water: Measurement of inlet and outlet flows, and flows within the treatment process Climate engineering: Water metering (hot or cold) for air conditioning Chemical products, even aggressive liquids: Process control, system management Food/farming products Crude oil: Management of samplers for controlling loading/unloading Refined oil products or liquefied gas (LPG): Regulation and control of transport system Energy: calculation of the yield from hydroelectric power stations * please enquire expert in flow meters s i n c e 1 974

 Open the catalog to page 1
Uf 831 - Fixed ultrasonic flow meter for full pipe-2

Uf 831 model si ngl e p i p e mult i-pipe Fixed Internal diameter of pipe From 8mm to 9,900mm approximately (depending on wall thickness) external diameter of pipe From 10mm to 10,000mm in put/o ut put › With Field bus option: Up to 5 programmable input/output modules › Without Field bus option: Up to 10 programmable input/output modules 2 man dato r y base mo d ul e s › isolated active analogue output: current 4-20mA, 0-20mA, 0-24mA 1 › static relay digital outputs (50 V - 10 mA) usable on frequency outputs 2 i n op ti on, othe r mo d ul e s avail abl e › › › › › › i n op ti on, calorimetric...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.