1. Catalogs
  2. ultrafilter Skandinavien Aps
  3. VX1 element & VLR filterhus

VX1 element & VLR filterhus

VX1 element & VLR filterhus

VX1 element & VLR filterhus

Product catalog summary
Overview
This document provides technical specifications and features of vacuum pump protection filters designed for various applications including chemical, dental, electronics, emissions monitoring, food & beverage, fume extraction, laboratories, manufacturing, medical, military, packaging, paint applications, pharmaceutical manufacturing, pneumatic conveying, and printing & paper industries.

Design and Construction
The filters are manufactured with an optimized modular housing design using cast aluminium alloy with Walker E-Coat protection, ensuring robustness and corrosion resistance. They are suitable for both rough and high vacuum applications.

Filtration Media
The filters use oleophobic borosilicate media with a custom-engineered anti re-entrainment layer, providing exceptional dirt holding and drainage capabilities. This unique construction minimizes pressure drop, enhancing energy efficiency and ensuring reliable filtration.

Element Features
High-efficiency elements prevent liquid contamination and damage to vacuum pump parts. The elements feature a unique self-centralizing, drop-fit, anti-vibration design with color-coded end caps for easy identification and stability.

Technical Specifications
  • Airflow direction is inside to out through the filter element.
  • Pop-up indicators and differential pressure gauges are fitted to specific models.
  • Manual drain valves are standard, with options for adaptation.
  • Threaded filters comply with PED 97/23/EC for group 2 gases.
  • Connections are available in Rp (BSP parallel) or NPT standards.
  • Filter elements should be replaced every 12 months or 8000 hours.

Performance Parameters
  • Particle removal: 5 micron (VLR) and 1 micron (VX1).
  • Maximum oil carryover: 1 mg/m³ at 20°C.
  • Maximum temperature: 120°C (248°F).
  • Pressure loss: 20 mbar (clean & dry) and 100 mbar (element change).
  • Maximum working pressure: 16 barg (232 psig).
  • Maximum working vacuum: full vacuum.

Model Specifications
The document includes detailed specifications for various models, including pipe size, exhaust flow rate, dimensions, weight, and element model. Correction factors for maximum flow rate based on operating vacuum are also provided.
See more

Catalog excerpts

VX1 element & VLR filterhus-1

Vacuum Pump Protection Applications include Chemical Dental The vacuum pump protection filter range covers the most popular size of vacuum pumps and is suitable for both rough vacuum and high vacuum applications. Electronics Emissions Monitoring Food & Beverage Fume Extraction Optimised modular housing design ensures high performance and ease of installation. Manufactured in cast aluminium alloy with Walker E-Coat protection for a robust and corrosion resistant product. Laboratories Manufacturing Medical Unique media delivers exceptional filtration Oleophobic borosilicate media and a custom engineered anti re-entrainment layer guarantees exceptional dirt holding and drainage capabilities. Unique material construction minimises pressure drop delivering reliable filtration with improved energy efficiency. High efficiency elements prevent liquid contamination and damage to rotating parts in the vacuum pump. Unique self centralising, drop-fit, anti-vibration, colour coded elements Our advanced element end cap design improves stability, prevents vibration and assists with drainage by engaging within the bowl. They are also colour coded for easy grade identification. Independent testing and validation guarantees peace of mind. Military Packaging Paint Applications Pharmaceutical Manufacturing Pneumatic Conveying Printing & Paper

 Open the catalog to page 1
VX1 element & VLR filterhus-2

Vacuum Pump Protection D Technical Specification filter model exhaust flow rate (vacuum displacement) Nm3/h A038 (grade) A058 (grade) D A059 (grade) A078 (grade) A079 (grade) A108 (grade) A109 (grade) A128 (grade) A158 (grade) A A159 (grade) B A208 (grade) A209 (grade) A254 (grade) C A340 (grade) A360 (grade) A390 (grade) element model Particle removal Maximum temperature Pressure loss - change element Pressure loss - clean & dry Maximum working pressure Maximum working vacuum full vacuum full vacuum technical notes Direction of air flow is inside to out through the filter element. Pop up indicators...

 Open the catalog to page 2

All Ultrafilter Skandinavien Aps catalogs and technical brochures

  1. UltraDry HP

    4  Pages

  2. UltraDry UD

    2  Pages

  3. AG-Z cyklon

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.