Overview: The document provides technical information on UGA-Wallcollars MK, designed for hydrostatic sealing of various pipe materials passing through structural elements like walls and floors. It highlights the product's suitability for situations where retrofitting wall sleeves or drilling holes is not feasible.
Specifications: UGA wallcollars are effective against groundwater and pressing water. They are tested for pipes with outer diameters from Ø 32 mm to Ø 315 mm up to 5 bar, and from Ø 355 mm up to 4 bar. The material used is high-quality rubber with a tensile strength of 9.5 N/mm², elongation at break of 500%, and a Shore hardness of 45 +/- 5°. The service temperature ranges from -40°C to 80°C.
Installation Instructions: The installation involves cleaning the pipe surface, sliding the wallcollar to the center of the concrete or wall, attaching fastening straps, and securing them with a turnbuckle. It is crucial to note that the UGA-wallcollar is not an anchoring device for pipes.
Dimensions and Article Numbers: The document lists dimensions and corresponding article numbers for various pipe outer diameters, ranging from Ø 32 mm to Ø 1400 mm, providing a comprehensive guide for selecting the appropriate wallcollar size.
Additional Information: UGA SYSTEM-TECHNIK GmbH & Co. KG offers a guarantee of quality for all products and provides a 24-hour delivery service on demand. They also offer replacement parts for material defects affecting functionality, excluding those caused by transport, storage, or incorrect installation.
See more

Catalog excerpts

Wallcollars MK-1

Building Technology Systems www.uga.eu Cable- and pipe entries SYSTEM-TECHNIK UGA-Wallcollars MK Technical information 24 hour delivery service Global distribution network Service-Hotline Tel. +49 7324 9696-33 we are happy to assist you

 Open the catalog to page 1
Wallcollars MK-2

► General information Hydrostatic sealing of pipes made of steel, cast iron, copper, plastic, fibre reinforced concrete, concrete and vitrified clay that pass through walls, ceilings, floors, shaft openings, swimming pools and groundwater troughs. UGA wallcollars are the ideal solution wherever it is not possible to retrofit wall sleeves or drill holes. Note: The UGA-wallcollar is not an anchoring for pipes! • Tight against groundwater and pressing water • For pipes with outer diameter of 0 32 mm until 0 315 mm tested up to 5 bar • From pipe outer diameters 355 mm tested up to 4 bar ► Dimensions...

 Open the catalog to page 2

All UGA System-Technik catalogs and technical brochures

  1. FHE

    2  Pages

  2. GE

    2  Pages

  3. FU

    8  Pages

  4. GPD

    6  Pages

  5. KSS

    6  Pages

  6. BKD 90

    6  Pages

  7. KD 110

    6  Pages

  8. RRD/RDZ

    4  Pages

  9. SBT

    4  Pages

  10. MSD/MFD

    6  Pages

  11. KR

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.