Cable Protection Systems Overview
The KSS Cable Protection System is engineered for effective sealing and flexible cable management, allowing for immediate directional changes post-building emergence. It is compatible with standard protective tubes and ensures cables remain undamaged by building or soil movements, providing gas- and watertight connections without costly earthworks.

System Components and Variants
The system includes a flexible, stress-resistant plastic spiral hose. Components can be mixed within a system or hose size, facilitating connections to sealing collars or drilled holes. Variants include KSS B150, KSS 150, KSS 110, and KSS 85, each catering to different connection needs. System covers with various connection pieces are available for sealing cables using shrink-on techniques, and the Rubber Press Seal GPD ensures gas- and watertight connections.

Application and Function
Cables are sealed using heat or cold shrink-on sleeves, with unused connections sealed with plugs for future use. The system offers replacements for parts with material faults but not for transport or installation defects.

Technical Specifications
The system provides spiral hoses in various sizes with specific bending radii and wall thicknesses. Accessories include pipe clamps, sealing plugs, and installation tools.

Testing and Certification
Fraunhofer Gesellschaft Bremen conducted tests confirming the system's gas- and watertight properties, including gastightness, presswater tightness, and shock wave resistance.

Water Tightness at Low Temperatures
Specimens were tested for presswater tightness using a water/antifreeze solution at low temperatures for 24 hours. The BKD 150-D3/60 cover was tested for helium gastightness and presswater tightness, confirming excellent sealing capabilities.

Test Parameters
Tests included gastightness with air at 1 bar, presswater tightness at 5 bars, gastightness with helium at 5 bars, and presswater tightness at low temperatures at 5 bars at -27°C / -25°C.

Shock Wave Test Results
Results for KD 85, KD 110, and KD 150 showed varying pressure resistances, with the highest being 21.92 bars for KD 150 D3/60.

Gastightness Test Result
The partial pressure after setup was 5.4 x 10-6 mbars, superior to the atmospheric helium partial pressure of approximately 4.8 x 10-6 mbars.

Presswater Tightness Test Result
No liquid emerged, indicating the effective structure of the sealing collar and expansion seal, ensuring the connection remains intact as concrete dries.

Contact Information
UGA SYSTEM-TECHNIK GmbH & Co. offers technical systems and products for building integration. Contact them via phone, fax, or email for more information.
See more

Catalog excerpts

KSS Cable Protection Systems-1

KSS KSS KSS KSS B150 150 110 85 Cable Protection Systems iinng id eas e ad L SYSTEM-TECHNIK

 Open the catalog to page 1
KSS Cable Protection Systems-2

KSS Cable Protection System Your advantage Cable Protection System KSS offers many ways of application. The most common are shown under ᕡ to ᕨ. The KSS system consists of a flexible, very stress-resistant plastic spiral hose. The system components can be chosen at random and ensure connection to an imbedded sealing collar or diamond tipped drilled hole on one side. On the other side, connection to rigid or flexible cable protective tubes or sealing of the inserted cables is possible. ᕡ D/K ̈ ̈ ̈ ̈ ̈ ̈ ̈ ̈ Cable Protection System, one side for connection to concreted sealing collar. Other side...

 Open the catalog to page 2
KSS Cable Protection Systems-3

System Components Application and Function KSS system components can be combined at random within one system size or hose size. The components shown here can be chosen for this purpose. System connection D (for BKD 150) for gas- and watertight connection to a bayonet sealing collar. Available for system: KSS B150. Sealing collar with combination frame K for reception of a system connection or a system cover. Available for systems: KSS B150, KSS 150, KSS 110, KSS 85 System connection D (for KD 150, KD 85) for gas- and watertight screw connection to a sealing collar. Available for systems: KSS...

 Open the catalog to page 3
KSS Cable Protection Systems-4

KSS Variants KSS B150 / KSS 150 / KSS 110 / KSS 85 ᕡ ᕢ ᕣ ᕤ ᕥ ᕦ ᕧ ᕧ ᕧ ᕨ ᕡ ᕢ ᕣ ᕤ ᕥ ᕦ ᕧ ᕧ ᕧ ᕨ ᕡ ᕢ ᕣ ᕤ ᕥ ᕦ ᕧ ᕧ ᕧ ᕨ ᕡ ᕢ ᕣ ᕤ ᕥ ᕦ ᕧ ᕧ ᕧ ᕨ side one side two with sealing collar BKD 150 KSS B150/110/D/K/ (L) with sealing collar BKD 150 with sealing collar BKD 150 KSS B150/110/K(B)2/ (L) for connection to sealing collar BKD 150 for connection to sealing collar BKD 150 KSS B150/110/D2/ (L) for connection to sealing collar BKD 150 without connecting element KSS B150/110/D/0/ (L for connection to sealing collar BKD 150 with glue-type sleeve for connection of a pipe Øo 110 mm KSS B150/110/D/KM110/ (L) with...

 Open the catalog to page 4
KSS Cable Protection Systems-5

Accessory Pipe Clamp RS for parallel guiding of KSS systems next to each other or one on top of the other (extendable). ✎ order no.: RS 90 for hose Øi 80 mm ✎ order no.: RS 125 for hose Øi 110 mm ✎ order no.: RS 140 for hose Øi 125 mm ✎ order no.: RS 170 for hose Øi 150 mm Double Pipe Clamp RSD for parallel guiding of two KSS systems. ✎ order no.: RSD 90 for hose Øi 80 mm ✎ order no.: RSD 125 for hose Øi 110 mm ✎ order no.: RSD 140 for hose Øi 125 mm ✎ order no.: RSD 170 for hose Øi 150 mm GSS VMS Sealing Plugs VS for sealing unused cover connection pieces. Plugs can be removed for using the...

 Open the catalog to page 5
KSS Cable Protection Systems-6

Test Report UGA Systems BKD 150 and KD The tests with systems BKD 150 and KD were carried out at the Fraunhofer Gesellschaft Bremen (IFAM). These tests were to show if UGA’s cable bushings type KD 85, KD 110, KD 150, BKD 150 and system KSS are gas- and watertight. A special test specimen consisting of a concrete part and a test bell was developed for this test. The corresponding sealing collar was imbedded into the concrete part with a waterproof concrete. The surface of the concrete part was sealed as this test was to reveal the bonding characteristics of the sealing collar to the concrete and...

 Open the catalog to page 6

All UGA System-Technik catalogs and technical brochures

  1. FHE

    2  Pages

  2. GE

    2  Pages

  3. FU

    8  Pages

  4. GPD

    6  Pages

  5. KSS

    6  Pages

  6. BKD 90

    6  Pages

  7. KD 110

    6  Pages

  8. RRD/RDZ

    4  Pages

  9. SBT

    4  Pages

  10. MSD/MFD

    6  Pages

  11. KR

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.