PE - 1

COMPONENTS PRESSURE F I LT E R S PE MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile (FKM - on request uoroelastomer) Indicator housing: Brass PRESSURE (ISO 10771-1:2002) Max working: 1,2 MPa (12 bar) Test: 1,5 MPa (15 bar) Bursting: 2,5 MPa (25 bar) Collapse, differential for the lter element (ISO 2941): 400 kPa (4 bar) APPLICATION EXAMPLE BYPASS VALVE Setting: 170 kPa (1,7 bar) ± 10% WORKING TEMPERATURE From -25° to +110° C COMPATIBILITY (ISO 2943:1999) Full with uids: HH-HL-HM-HR-HV-HTG (according to ISO 6743/4) For uids different than the above mentioned, please contact our Sales Department.

Open the catalog to page 1
PE - 3

P R E S S U R E F I LT E R S ORDERING AND OPTION CHART TYPE F = FILTER COMPLETE B = FILTER HOUSING F F F F B B B F B F B F B F B 11 12 21 22 31 32 41 42 B - B - B - B - B - B - B B 06 06 10 - - - 10 - - - - 12 12 12 12 W B W W B W B W W W B W B N N F N F N F N F N F N N FILTER MEDIA FA = fiber 5 m(c) >1.000 FB = fiber 7 m(c) >1.000 FC = fiber 12 m(c) >1.000 FD = fiber 21 m(c) >1.000 CC = cellulose 10 m >2 CD = cellulose 25 m >2 FA FB FC FD CC CD FA FB FC FD CC CD FA FB FC FD CC CD FA FB FC FD CC CD FA FB FC FD CC CD FA FB FC FD CC CD FA FB FC FD CC CD FA FB FC FD CC CD CLOGGING INDICATOR 06...

Open the catalog to page 3
PE - 5

P R E S S U R E F I LT E R S ORDERING AND OPTION CHART F F F F F F F F B 06 = 3/4 B B B B A2 B1 B2 31 32 41 42 B - B - B - B - B - B B 06 PORT SIZE B B - PORT TYPE B = BSP thread F = SAE flange 3000 psi B A1 FAMILY NOMINAL SIZE & LENGTH B 06 - 10 - 10 - - - 12 12 12 12 - 10 = 1" 1/4 - 12 = 1" 1/2 BYPASS VALVE W = without B = 170 kPa (1,7 bar) SEALS - - - - F - - F - - W B B W B W B W B W B W B N N N N F N F N N FA FB FC FD CC CD FA FB FC FD CC CD FA FB FC FD CC CD FA FB FC FD CC CD FA FB FC FD CC CD FA FB FC FD CC CD FA FB FC FD CC CD FA FB FC FD CC CD 0U U0 N0 0U U0 N0 0U U0 N0 03 03 03 03...

Open the catalog to page 5
PE - 6

PE P R E S S U R E F I LT E R S FLUID SPEED when selecting the filter size, we suggest to consider also the max recommended fluid speed (in pressure lines normally 5 < v < 10 m/s). 800 750 Recommended range 700 5 < v < 10 m/s 650 FLOW RATE [l/min] 600 550 500 450 400 350 300 250 200 150 100 50 0 3/4” 1” 1/4 1” 1/2 PORT SIZE PRESSURE DROP CURVES (∆p) The “Assembly Pressure Drop (∆p)” is obtained by adding the pressure drop values of the Filter Housing and of the Clean Filter Element corresponding to the considered Flow Rate and it must be lower than 50 kPa (0,5 bar). FILTER HOUSING PRESSURE...

Open the catalog to page 6
PE - 7

P R E S S U R E F I LT E R S PRESSURE DROP CURVES (∆p) PE The “Assembly Pressure Drop (∆p)” is obtained by adding the pressure drop values of the Filter Housing and of the Clean Filter Element corresponding to the considered Flow Rate and it must be lower than 50 kPa (0,5 bar). CLEAN FILTER ELEMENT PRESSURE DROP WITH F+ AND C+ MEDIA (depending both on the internal diameter of the element and on the filter media) Δp (bar) Δp (kPa) 1 0,75 75 0,5 50 0,25 ESE 11 100 25 0 FA FC FD CC 25 50 75 0,5 50 0,25 ESE 21 100 0,75 25 0 CD FA FB FC FD CC 50 1 0,75 75 0,5 50 0,25 CD 100 150 200 250 300 l/min...

Open the catalog to page 7
PE - 8

PE P R E S S U R E F I LT E R S CLOGGING INDICATOR A visual or electrical indicator is available as an option and allows monitoring of the element conditions, giving an indication of the right time to replace the element. BYPASS VALVE In the head, a full-flow bypass valve can be mounted as an option; the bypass flow is designed in such a way that the contaminant is retained in the filter element during bypass conditions. “LONG LIFE” FILTER ELEMENT The filter elements are designed with a very large filter area giving a highest dirt holding capacity. EASY MAINTENANCE The spin-on cartridge...

Open the catalog to page 8
PE - 9

P R E S S U R E F I LT E R S VERSION WITH DIFFERENTIAL INDICATOR CLOGGING INDICATOR A visual or visual-electrical differential indicator is available as an option and allows monitoring of the element conditions, giving an exact indication of the right time to replace the element. CLOGGING INDICATOR For further technical informations and other options see page 182-183. BYPASS VALVE In the head, a full-flow bypass valve can be mounted as an option; the bypass flow is designed in such a way that the contaminant is retained in the filter element during bypass conditions. “LONG LIFE” FILTER...

Open the catalog to page 9

All UFI HYDRAULIC catalogs and technical brochures

  1. AIR SENTRY

    2 Pages

  2. CSE – SBB

    2 Pages

  3. CBS – SAB

    2 Pages

  4. CBF – FA

    2 Pages

  5. CBE – FA

    2 Pages

  6. CBD – FA

    2 Pages

  7. CBC – TSP

    2 Pages

  8. CBB – FA

    2 Pages

  9. CBA-TM

    2 Pages

  10. FAB

    3 Pages

  11. CLB – LME

    2 Pages

  12. CFA-TM

    3 Pages

  13. AIR FILTERS

    11 Pages

  14. SA -SB

    4 Pages

  15. MA

    5 Pages

  16. PG

    5 Pages

  17. HYDRO DRY

    2 Pages

  18. UOW

    2 Pages

  19. OF

    6 Pages

  20. RH

    8 Pages

  21. RG

    6 Pages

  22. RF

    14 Pages

  23. RD

    6 Pages

  24. RC

    6 Pages

  25. RB

    6 Pages

  26. RA

    7 Pages

  27. PM

    6 Pages

  28. PL

    10 Pages

  29. PH

    6 Pages

  30. PD

    8 Pages

  31. PC

    5 Pages

  32. PB

    10 Pages

  33. PA

    5 Pages

  34. SE

    5 Pages

  35. SD

    6 Pages

  36. sc_heavy

    5 Pages

  37. SC

    5 Pages

Archived catalogs