Catalog excerpts
COMPONENTS PRESSURE F I LT E R S PC MATERIALS Head: Cast iron Bowl: Steel Bypass valve: NBR Nitrile (FKM - on request uoroelastomer) Seals: NBR Nitrile (FKM - on request uoroelastomer) Indicator housing: Brass PRESSURE (ISO 10771-1:2002) Max. working: 31,5 MPa (315 bar) Test: 47 MPa (470 bar) Bursting: 95 MPa (950 bar) Collapse, differential for the lter element (ISO 2941): series standard 2 MPa (20 bar) serie H+ 21 MPa (210 bar) APPLICATION EXAMPLE BYPASS VALVE Setting: 600 kPa (6 bar) ± 10% WORKING TEMPERATURE From -25° to +110° C COMPATIBILITY (ISO 2943:1999) Full with uids: HH-HL-HM-HV-HTG (according to ISO 6743/4) For uids different than the above mentioned, please contact our Sales Department.
Open the catalog to page 1P R E S S U R E F I LT E R S ORDERING AND OPTION CHART P C TYPE F = FILTER COMPLETE B = FILTER HOUSING F F B 21 B PORT TYPE B = BSP - thread PORT SIZE 04 = 1/2" 06 = 3/4" 08 = 1" 22 04 06 FAMILY, SIZE & LENGTH B 04 06 E P B 08 08 BYPASS VALVE ELEMENT FAMILY SIZE & LENGTH W = without C = 600 kPa (6 bar) SEALS SEALS N = NBR F = FKM N = NBR Nitrile F = FKM Fluoroelastomer FILTER MEDIA FA = fiber 5 m(c) >1.000 ∆p 2MPa (20 bar) FB = fiber 7 m(c) >1.000 ∆p 2MPa (20 bar) FC = fiber 12 m(c) >1.000 ∆p 2MPa (20 bar) FD = fiber 21 m(c) >1.000 ∆p 2MPa (20 bar) HA = fiber 5 m(c) >1.000 ∆p 21MPa (210...
Open the catalog to page 3PC P R E S S U R E F I LT E R S FLUID SPEED when selecting the lter size, we suggest to consider also the max recommended uid speed (in pressure lines normally 5 < v < 10 m/s). 350 Recommended range 5 < v < 10 m/s FLOW RATE [l/min] 300 250 200 150 100 50 0 1/2” 3/4” 1” PORT SIZE PRESSURE DROP CURVES (∆p) The “Assembly Pressure Drop (∆p)” is obtained by adding the pressure drop values of the Filter Housing and of the Clean Filter Element corresponding to the considered Flow Rate and it must be lower than 120 kPa (1,2 bar). FILTER HOUSING PRESSURE DROP (mainly depending on the port size) Δp...
Open the catalog to page 4P R E S S U R E F I LT E R S CLOGGING INDICATOR A visual or visual-electrical differential indicator is available as an option and allows monitoring of the element conditions, giving an exact indication of the right time to replace the element. CLOGGING INDICATOR FILTER HOUSING Head and bowl are made by high performance aluminium alloy ensuring the best fatigue resistance. FILTER ELEMENT The filter element is manufactured with filter medias selected in the UFI laboratory and mechanically supported to maintain the highest performance even at high differential pressures. PC SEAL GUARANTEED A...
Open the catalog to page 5All UFI HYDRAULIC catalogs and technical brochures
-
AIR SENTRY
2 Pages
-
CSE – SBB
2 Pages
-
CBS – SAB
2 Pages
-
CBF – FA
2 Pages
-
CBE – FA
2 Pages
-
CBD – FA
2 Pages
-
CBC – TSP
2 Pages
-
CBB – FA
2 Pages
-
CBA-TM
2 Pages
-
FAB
3 Pages
-
CLB – LME
2 Pages
-
CFA-TM
3 Pages
-
CATALOGUE 2018/2019
284 Pages
-
AIR FILTERS
11 Pages
-
SA -SB
4 Pages
-
MA
5 Pages
-
CLOGGING INDICATORS
7 Pages
-
PG
5 Pages
-
HYDRO DRY
2 Pages
-
UOW
2 Pages
-
OF
6 Pages
-
CBA - CBB - Air breathers
11 Pages
-
RH
8 Pages
-
RG
6 Pages
-
RF
14 Pages
-
RD
6 Pages
-
RC
6 Pages
-
RB
6 Pages
-
RA
7 Pages
-
PM
6 Pages
-
PL
10 Pages
-
PH
6 Pages
-
PE
9 Pages
-
PD
8 Pages
-
PB
10 Pages
-
PA
5 Pages
-
SE
5 Pages
-
SD
6 Pages
-
sc_heavy
5 Pages
-
SC
5 Pages