CLOGGING INDICATORS-1

CLOGGING INDICATORS DESCRIPTION During the system operation, the pressure drop through the lter increases as the element clogs, due to the contaminant retained. The lter element must be replaced when clogged and anyway before the pressure drop reaches the bypass valve set value. For this reason it is recommended a clogging indicator on the lter. It gives a visual or electrical indication and must have a set value lower than the bypass valve set value, to get an exact indication of the right time for lter element replacement. PRESSURE FILTERS INDICATORS Pressure gauges Pressure switches Differential, visual Differential, electrical Differential, el. + LED Differential, el. + thermostat Differential, el. + visual Differential, el. Vandal proof Differential, el. ATEX RETURN FILTERS INDICATORS Pressure gauges Pressure switches Differential, visual Differential, electrical Differential, el. + LED Differential, el. + thermostat Differential, el. + visual Differential, el. ATEX OFF-LINE FILTERS INDICATORS SUCTION FILTERS INDICATORS Differential, visual Differential, electrical Differential, el. + LED Differential, el. + thermostat Differential, el. + visual Differential, el. ATEX Vacuum gauges Vacuum switches On return and low pressure lters the clogging indicator can be a pressure gauge or a pressure switch, measuring the pressure upstream the lter. On some return lters and on high pressure lters, the clogging indicator can be of differential type: measuring the pressure upstream and downstream the lter and activating a signal when the differential pressure reaches the set value. On suction lters the clogging indicator is a vacuum gauge or a vacuum switch, measuring the depressure downstream the lter. All the UFI lters have the port for the indicator as a standard feature; if the lter is ordered without indicator the port is plugged with a removeable plug allowing the indicator to be added easily at any time.

 Open the catalog to page 1
CLOGGING INDICATORS-2

DIFFERENTIAL PRESSURE INDICATION PRESSURE FILTERS FOR PRESSURE FILTERS SERIES Pressure gauge Pressure gauge stainless steel, glycerine filled Pressure switch Setting 1,5 bar (150 kPa) SPDT, Max voltage 250V - 50 Hz - Max current 6 A resistive, 1 A inductive - Protection IP65 connector DIN 43650 SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectively C.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Differential VISUAL indicator Differential VISUAL indicators Recommended tightening torque 90 Nm Differential VISUAL...

 Open the catalog to page 2
CLOGGING INDICATORS-3

FOR PRESSURE FILTERS SERIES SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectively C.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Differential ELECTRICAL indicators with LED (24 V) for visual indication SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectively C.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Differential ELECTRICAL indicators with THERMOSTAT 30° C SPDT differential switch. C.C. 14 - 30 V: > max resistive or...

 Open the catalog to page 3
CLOGGING INDICATORS-4

PRESSURE INDICATION DIFFERENTIAL PRESSURE INDICATION RETURN FILTERS FOR RETURN FILTERS SERIES Pressure gauge stainless steel, glycerine filled ø 40 Pressure gauge stainless steel, glycerine filled ø 40 Pressure switch SPDT, Max voltage 250V - 50 Hz - Max current 6 A resistive, 1 A inductive - Protection IP65 connector DIN 43650

 Open the catalog to page 4
CLOGGING INDICATORS-5

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectively C.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Differential ELECTRICAL indicators with LED (24 V) for visual indication SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectively C.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Differential ELECTRICAL indicators with THERMOSTAT 30° C Setting 1,3 bar (130 kPa) SPDT differential switch. C.C. 14 - 30 V: > max resistive or...

 Open the catalog to page 5
CLOGGING INDICATORS-6

DIFFERENTIAL PRESSURE INDICATION SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectively C.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Differential ELECTRICAL indicators with LED (24 V) for visual indication SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectively C.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Differential ELECTRICAL indicators with THERMOSTAT 30° C Differential ELECTRICAL indicators SPDT differential switch....

 Open the catalog to page 6
CLOGGING INDICATORS-7

CLOGGING INDICATORS SUCTION FILTERS FOR SUCTION FILTERS SERIES Vacuum gauge Vacuum gauge Vacuum switch Setting 0,2 bar (20 kPa) SPDT SPDT, Max voltage 250V - 50 Hz - Max current 6 A resistive, 1 A inductive - Protection IP65 connector DIN 43650 Is this datasheet the latest release? Please check on our website. Technical data subject to variations without prior notice. INDICATORS - EN - 07/2013 Vacuum gauge Glycerine filled - 2 Scales

 Open the catalog to page 7

All UFI HYDRAULIC catalogs and technical brochures

  1. CSE – SBB

    2  Pages

  2. CBS – SAB

    2  Pages

  3. CBF – FA

    2  Pages

  4. CBE – FA

    2  Pages

  5. CBD – FA

    2  Pages

  6. CBC – TSP

    2  Pages

  7. CBB – FA

    2  Pages

  8. CBA-TM

    2  Pages

  9. FAB

    3  Pages

  10. CLB – LME

    2  Pages

  11. AIR FILTERS

    11  Pages

  12. PC

    5  Pages

  13. SA -SB

    4  Pages

  14. MA

    5  Pages

  15. PG

    5  Pages

  16. HYDRO DRY

    2  Pages

  17. UOW

    2  Pages

  18. OF

    6  Pages

  19. RH

    8  Pages

  20. RG

    6  Pages

  21. RF

    14  Pages

  22. RD

    6  Pages

  23. RC

    6  Pages

  24. RB

    6  Pages

  25. RA

    7  Pages

  26. PM

    6  Pages

  27. PL

    10  Pages

  28. PH

    6  Pages

  29. PE

    9  Pages

  30. PD

    8  Pages

  31. PB

    10  Pages

  32. PA

    5  Pages

  33. SE

    5  Pages

  34. SD

    6  Pages

  35. sc_heavy

    5  Pages

  36. SC

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.