QALCOSONIC E2
1 /6Pages

QALCOSONIC E2

QALCOSONIC E2
1 /6Pages

Catalog excerpts

QALCOSONIC E2-1

ULTRASONIC HEAT METER Ultrasonic heat meter QALCOSONIC E 2 is designed for metering of consumed heating or cooling energy in closed or open heating/cooling systems, installed in dwelling houses, office buildings or energy plants. Heat meter QALCOSONIC E 2 consists of the primary flow sensor and the calculator with type approved pair of temperature sensors with Pt500 elements. • High accuracy SPECIAL FEATURES • Heat meter can be used for heat and flow measurements in closed or open loop heat supply systems. • Two flow measurement channels. • Two pressure measurement channels. • Two pulse inputs for additional flow sensors. • Pre-programmed or measured pressure values may be used for energy calculation. • Cold water temperature for open loop application can be measured, or pre-programmed temperature value can be used. • Optional integrated regulation or alarm function. • Flexible menu setup - list of parameter values displayed on the LCD may be configured according to the customer's needs. • Power supply - from internal battery or 230 V AC power source. • Battery lifetime not less than 11 years. • Optical data interface according to EN 61107. • Optional communication modules.

 Open the catalog to page 1
QALCOSONIC E2-2

NOMINAL FLOW PARAMETERS

 Open the catalog to page 2
QALCOSONIC E2-3

*Values of the minimum flow rates for measurement schemes U1L and U2L (accounting of heating-cooling energy ) are presented in brackets. MOUNTING ON ULTRASONIC FLOW SENSOR Brass housing Steel housing

 Open the catalog to page 3
QALCOSONIC E2-4

TECHNICAL DATA DATA RECORDING AND STORAGE Following daily, weekly and monthly parameter values are recorded in heat meter memory: • absolute integral instantaneous parameter values • hourly, weekly and monthly alterations of integral parameters • hourly, weekly and monthly average values for all mea sured temperature and pressure values • error (fault) and information codes (see paragraph. 8.2.2) that occurred during the last hour, day and month Data logger capacity: • up to 110 days (3,5 months) - for hourly records. • up to 1461 days (36 last months) -. for daily and monthly records, Archive...

 Open the catalog to page 4
QALCOSONIC E2-5

The device is equipped with 8-digits LCD (Liquid Crystal Display) with special symbols to display parameters, measurement units and operation modes: 2. Parameter numbers 3. Operation mode 4. Measurenent units tm'/hkPa'GJcalMkWh 1. Groups of parameters The following information can be displayed: • Integral and instantaneous measured parameters; • Archive data; • Device configuration information; • Report printing control information; Display resolution (directly corresponding with pulse output value), depending on programmed maximum flow rate value Power supply for extra sensors • Voltage for...

 Open the catalog to page 5
QALCOSONIC E2-6

Axioma Metering UAB / Kulautuvos str. 45a / Kaunas LT-47190 / Lithuania / [email protected] / www.axiomametering.com