1. Catalogs
  2. A. u. K. Müller
  3. 2/2-way drain valve NC, DN 40 IP 65, IP 68

2/2-way drain valve NC, DN 40 IP 65, IP 68

2/2-way drain valve NC, DN 40 IP 65, IP 68

2/2-way drain valve NC, DN 40 IP 65, IP 68

Product catalog summary
Product Overview: The document provides detailed information about the 2/2-way direct acting drain valves, specifically the Series 04.040.116, designed by A.u.K. Müller GmbH & Co. KG. These valves are used for controlling low aggressive media such as cleaning or disinfection agents and operate in a normally closed (NC) mode.
Specifications: The valves have a nominal diameter of DN 40 and are available with protection types IP 65 and IP 68. They are constructed with a single chamber valve body, with the inlet positioned at ninety degrees to the outlet. The valve bodies can be made from PPE, PVDF, or stainless steel, each offering different levels of resistance to chemicals and temperature.
Applications: These valves are suitable for use in industrial washing machines, dishwashers, medical equipment cleaning devices, and disinfection systems in the dairy industry and process engineering.
Technical Features: The valves feature a potted coil system protected against corrosion, optional flush spouts, and an emergency manual override for drainage during power failures. They can handle a maximum medium temperature of 98°C (208°F) and do not require minimal pressure for operation.
Materials and Construction: The valve body materials include PPE, PVDF, and stainless steel, with stainless steel also used for the plunger guide, plunger, spring, and optional flush spout. The membrane and sealings are made from EPDM or FKM, and the coil coating is PBT with PU potting.
Electrical Specifications: The valves operate with a nominal voltage range from 12 V DC to 400 V AC/DC, with a voltage tolerance of ±10%. They have a duty cycle of 100% and a nominal power of 24 W.
Options and Accessories: The valves can be equipped with an emergency manual override and are available with different cable lengths. The stainless steel valve body combined with an FKM diaphragm is recommended for sterilization and disinfection equipment.
See more

Catalog excerpts

2/2-way drain valve NC, DN 40 IP 65, IP 68-1

Product Information 2/2-way drain valves NC, DN 40, IP 65, IP 68 A. u. K. Müller Solenoid valves Control valves Special valves and systems A.u.K. Müller GmbH & Co. KG Dresdener Str. 162 D-40595 Düsseldorf/Germany e-mail: [email protected] Internet: www.akmueller.de Characteristics Direct acting Protection type IP 68 using cable, respectively IP 65 using connector Normally closed (NC) Potted coil Coil system protected against corrosion by separation to medium by membrane Optional valve body made of PVDF or stainless steel and FKM membrane for higher resistance to chemicals Optional flush spout on valve body Valve body: PVDF Valve body: Stainless steel Optional manual emergency override Long term performance capability Maximum medium Applications Description 2/2-way direct acting drain valve of nominal diameter DN 40 for controlling low aggressive media, such as cleaning or disinfection agents, with normally closed operation mode NC (normally closed). Industrial washing machines and dishwashers Cleaning devices for medical equipment Cleaning and disinfection systems in the dairy industry and process engineering Valves of this type are medium separated having a single chamber valve body with the inlet at ninety degrees to the outlet. They can be manufactured in various materials and equipped with threaded or hose connections. Electrical operating safety is achieved by insulation class F and supported by an integrated protective circuit. temperature 98 °C (208 °F) No minimal pressure required Suitable for spray- and jet water UL approved versions available High operating safety by the use of high quality materials and 100% final testing of the products Typical performance curve p / psi 0,0 Protection type IP 68 is achieved in conjunction with cable connection, IP 65 by using a mounted connector. The smooth internal shape improves liquid flow and avoids dirt traps. The valve bodies can be equipped with an additional flush spout. Valve housing made of PPE or stainless steel are suitable for hot water. Valve housing made of PVDF have a higher resistance to chemicals where stainless steel has both features. The valves can be equipped with an emergency manual override, to ensure the drainage of tanks even in the case of a voltage breakdown. p / mbar © copyright A.u.K. Müller, subject to changes without prior notice

 Open the catalog to page 1
2/2-way drain valve NC, DN 40 IP 65, IP 68-2

Product Information 2/2-way drain valves NC, DN 40, IP 65, IP 68 Optional flush spout Technical Data Type drain valve 2/2-way-solenoid valve, direct acting Fitting position solenoid pointing upwards low aggressive media, such as cleaning or disinfection agents within potable water T-Medium PPE Stainless steel PVDF Coil type MS.010 integrated protection circuit (high voltage peak limitation) and rectifier Nominal voltage Thickness of the mounting flange for all valve bodies: 5 mm (0.197 in) Valve body: PVDF V DC V DC V AC/DC *) V AC/DC V AC/DC V AC/DC Voltage tolerance ±10% Duty cycle Nominal...

 Open the catalog to page 2
2/2-way drain valve NC, DN 40 IP 65, IP 68-3

Product Information 2/2-way drain valves NC, DN 40, IP 65, IP 68 without emergency manual override Series 04.040.116 Options Material H with emergency manual override H without emergency manual override © copyright A.u.K. Müller, subject to changes without prior notice

 Open the catalog to page 3
2/2-way drain valve NC, DN 40 IP 65, IP 68-4

Product Information 2/2-way drain valves NC, DN 40, IP 65, IP 68 with emergency manual override Pull ball handle to open the valve © copyright A.u.K. Müller, subject to changes without prior notice

 Open the catalog to page 4
2/2-way drain valve NC, DN 40 IP 65, IP 68-5

Product Information 2/2-way drain valves NC, DN 40, IP 65, IP 68 without emergency manual override Series 04.040.116 Options Material Without emergency manual override Stainless steel on request With emergency manual override © copyright A.u.K. Müller, subject to changes without prior notice

 Open the catalog to page 5
2/2-way drain valve NC, DN 40 IP 65, IP 68-6

Product Information 2/2-way drain valves NC, DN 40, IP 65, IP 68 with emergency manual override Pull ball handle to open the valve © copyright A.u.K. Müller, subject to changes without prior notice

 Open the catalog to page 6

All A. u. K. Müller catalogs and technical brochures

  1. Series 11.000

    4  Pages

  2. Vending

    16  Pages

  3. Industry

    16  Pages

  4. Sanitary

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.