KATflow 100
12Pages

{{requestButtons}}

Catalog excerpts

KATflow 100 - 1

KATflow 100 Standard Clamp-On Ultrasonic Flow Transmitter SMALL. SIMPLE. STURDY. The KATflow 100 is a compact clamp-on ultrasonic flow transmitter with a robust and practical design for permanent installation and flow measurement on single pipes. The instrument offers a cost-effective option owing to its simplified specification and the availability of a range of transducer types. The varied functionality and simple operation of the KATflow 100 make it the perfect product for large projects and customer specific solutions.

Open the catalog to page 1
KATflow 100 - 2

Fixed Installation Specification • Pipe diameter range 10 mm to 3,000 mm • Temperature range for sensors -30 °C to +80 °C (-22 °F to +176 °F) • Weight 750 g • Robust IP 66 aluminium enclosure • Sturdy unit with LCD display and five-key keypad • Wall or pipe mounted Features • Low cost of ownership • Process outputs including RS 485, Modbus RTU and HART* compatible output • PT100 inputs for heat quantity (thermal energy) measurement • Bi-directional measurement with totaliser function • Innovative installation wizard for quick and intuitive programming • Configuration can be changed to suit...

Open the catalog to page 2
KATflow 100 - 3

The Technology Behind the Measurement The KATflow non-invasive flowmeters work on the transit time ultrasonic principle. This involves sending and receiving ultrasonic pulses from a pair of sensors and examining the time difference in the signal. Katronic uses clamp-on transducers that are mounted externally on the surface of the pipe and which generate pulses that pass through the pipe wall. The flowing liquid within causes time differences in the ultrasonic signals, which are then evaluated by the flowmeter to produce an accurate flow measurement. The key principle of the method applied...

Open the catalog to page 3
KATflow 100 - 4

KATflow 100 Technical Data: Transmitter Performance Measurement principle Ultrasonic transit-time difference Flow velocity range Volume flow: ±1 ... 3 % of measured value depending on application ±0.5 % of measured value with process calibration Flow velocity (mean): ±0.5 % of measured value Turn down ratio Measurement rate Response time Damping of displayed value Gaseous and solid content of liquid media

Open the catalog to page 4
KATflow 100 - 5

General Enclosure type Wall mounted, optional pipe stands and brackets available Operating temperature Housing material Die-cast aluminium Measurement channels Power supply 100 ... 240 V AC, 50/60 Hz 9 ... 36 V DC Special solutions (e.g. solar panel, battery) on request LCD graphic display, 128 x 64 dots, backlit 120 (h) x 160 (w) x 81 (d) mm (without cable glands) Power consumption Operating languages English, French, German, Dutch, Spanish, Italian, Russian, Czech, Turkish, Romanian (others on request) Communication Type RS 232 (used for external programming and data transfer), USB cable...

Open the catalog to page 5
KATflow 100 - 6

KATdata+ software Functionality Download of measured values/parameter sets, graphical presentation, list format, export to third party software, online transfer of measured data Operating systems Windows 8, 7, Vista, XP, NT, 2000 Linux Quantity and units of measurement Volumetric flow rate m 3 /h, m 3 /min, m 3 /s, l/h, l/min, l/s USgal/h (US gallons per hour), USgal/min, USgal/s bbl/d (barrels per day), bbl/h, bbl/min Flow velocity Mass flow rate Heat flow W, kW, MW (with heat quantity measurement option) Heat quantity J, kJ, kW/h (with heat quantity measurement option) °C (with heat...

Open the catalog to page 6
KATflow 100 - 7

KATflow 100 Technical Data: Transducers K1P, K1L Pipe diameter range Dimensions of sensor heads Material of sensor heads Type K1L: Stainless steel Type K1P: Plastic Material of cable conduits Temperature range Standard cable lengths

Open the catalog to page 7
KATflow 100 - 8

K4P, K4L Pipe diameter range Dimensions of sensor heads Material of sensor heads Type K4P: Plastic Type K4L: Stainless steel Material of cable conduits Temperature range Standard cable lengths K4N transducers mounted using straps and clamps

Open the catalog to page 8
KATflow 100 - 9

Extension cable Available lengths Cable type Material of cable jacket Operating temperature Minimum bend radius Cable connection Connection types Termination into transmitter Direct cable connection (terminal block) Technical Data: Transducer Mounting Accessories Diameter range and mounting types Clamping set (metal strap with screw), stainless steel: DN 10 ... DN 40 Metallic straps and clamps: Metallic straps and clamps: Metallic mounting rail and straps (available on request): DN 50 ... DN 250 or DN 50 ... DN 3,000 Mounting fixture for flexible hoses Custom made mounting bracket,...

Open the catalog to page 9
KATflow 100 - 10

KATflow 100 Technical Data: PT100 Clamp-On Sensors General Type Measurement range Response time Dimensions of sensor heads Material of sensor heads Material of cable jacket Cable length PT100 transducer fixed to pipe PT100 with wired cable connection

Open the catalog to page 10
KATflow 100 - 11

KATflow 100 Configuration Code: Transmitter and Accessories KF 100 Ultrasonic flow transmitter KATflow 100, one measurement channel, serial interface RS 232, operating instructions Configuration 2 With LCD graphic display, 128 x 64 dots, backlit and 5-key keypad Internal code 03 Internal code Power supply 1 100 … 240 V AC, 50/60 Hz 2 9 … 36 V DC Z Special (please specify) Enclosure type 1 Die-cast aluminium, wall mounted, IP 66 Z Special (please specify) Communication 0 Without 1 RS 485 serial interface 2 Modbus RTU protocol 1) Z Special (please specify) Process inputs/outputs (select a...

Open the catalog to page 11
KATflow 100 - 12

KATflow 100 Configuration Code: Transducers and Accessories K4L K1P K1L Z Transducer pair, pipe diameter range 10 ... 250 mm, process temperature -30 ... +80 °C, including acoustic coupling paste Transducer pair, pipe diameter range 50 ... 500 mm, process temperature -20 ... +50 °C, including acoustic coupling paste Transducer pair, pipe diameter range 50 ... 3,000 mm, process temperature -30 ... +80 °C, including acoustic coupling paste Special (please consult factory) Internal code 03 Internal code Degree of protection 1 IP 66 (standard) 2 IP 67 (please consult factory) 3 IP 68 (please...

Open the catalog to page 12