1. Catalogs
  2. Tyco
  3. rapid response Home Fire Sprinkler System

rapid response Home Fire Sprinkler System
1 /16Pages

rapid response Home Fire Sprinkler System

rapid response Home Fire Sprinkler System
1 /16Pages

Catalog excerpts

rapid response Home Fire Sprinkler System-1

rapid nesponse Ktfl Home Fire Sprinkler System SERIES LFII SPRINKERS BLAZEM ASTER" CPVC PIPE & FITTINGS Sprinkler System Components

 Open the catalog to page 1
rapid response Home Fire Sprinkler System-4

Sries LFII Sprinklers lfU{TV2234) Pendent Recessed Pendent and Domed Concealed ► Fast response 3 mm bulb type 镕 Approved for spcial applications with beamed ceilings ► Used in wet pipe rsidentiel sprinkler Systems for one- and two-family dwellings and mobile homes per NFPA 13D 驕 Used in wet pipe rsidentiel occupancies up to and including four stories in height per NFPA 13R » Used in wet pipe sprinkler Systems for the residential portions of any occupancy per NFPA 13 KFactor K=4.9 (70,6) Thread&ze 72" Il 5 mm Escutcheon Style 20 Hniati White, Chrome, Brass, Custom Tech Data TFP400 MAXIMUM COVERAGE...

 Open the catalog to page 4
rapid response Home Fire Sprinkler System-5

Lfii(TYi334) Horizontal and Recessed Horizontal Sidewall Fast response Օ 3 mm bulb type Used in wet pipe rթsidentiel sprinkler Systems for one- and two-family dwellings and mobile homes per NFPA 130 Used in wet pipe rթsidentiel occupancies up to and including four stories in height per NFPA 13R Used in wet pipe sprinkler Systems for the residential portions of any occupancy per NFPA 13 K Factor '42 (60,5) Thread Size 1/2' (15 mm; Escutcheon Style 20 Finish White, Chrome, Brass Tech Data TFP410 MINIMUM FLOW & RESIDU A MAXIMUM COVERAGE AREA MAXIMUM SPAC1NG SSURE ft x It (m x m) ft{m> 4-BP MOOmm-150...

 Open the catalog to page 5
rapid response Home Fire Sprinkler System-6

Sries LFII Sprinklers LFIHTY2596) Fiat Plate Concealed Pendent FftSt response K Factor K=4.2 (60.5) 镕 Solder type Thread Size 1/2' [15 mm) * Can be used for horizontal and Finish White, Chrome, Brass, Custom sloped ceilings Tech Data TFP440 Usedm wetpipe rթsidentiel sprinkler Systems (or one- and two-farnily dwellings and mobile homes per NFPA13D Used in wet pipe residential sprinkler Systems lor residential occupancies up to and including four stones in height per NFPA 13R Օ Cover plate conceals sprinkler components above the ceiling MAXIMUM COVERAGE AREA hk ft (mx ml MAXIMUM SPAONG H M MINIMUM...

 Open the catalog to page 6
rapid response Home Fire Sprinkler System-7

LFIKTY2284) Flush Pendent Fost response Solder type Approved lor spcial applications with beamed ceilings Aesthetically plessing Used in wet pipe rsidentiel sprinkler Systems for one- and tvw>famity dwellings &nd mobile homes per NFPA 13D Used in wet pipe r驩sidentiel sprinkler Systems for rsidentiel occupancies up to and ncluding four stories in height per NFPA 13R Used in wet pipe sprinkler Systems (or the residentia portions of any occupancy per NFPA 13 < Fiic <=4,2 (60.5] Thread Size 1/2" (15 mm) Finish WNte, Chrome, Brass, Black MAXIMUM MAXIMUM MINIMUM FL0W & COVRAGE AREA SPACING RESIDUAL...

 Open the catalog to page 7
rapid response Home Fire Sprinkler System-8

NFPA 13 Optimized Sprinklers The large orifice 6.9 K( 5.6 K and 5.8 K sprinklers are primarily intended for residential use where there is a 0.1 gpm/sq. ft. densily NFPA 13 design requirement, and are generally used for installations in excess of four stories, They are optimized for residential applications where this higher water-flow demand is required. and can meet those requirements with less pressure and smalier pipe sizes. lfihty4234) Pendent, Recessed Pendent and Domed Concealed : Fast response 3 mm bulb type Used in wet pipe rsidentiel sprinkler Systems for one- and two-family dwellings...

 Open the catalog to page 8
rapid response Home Fire Sprinkler System-9

lfii(TY4334) Horizontal and Recessed Horizontal Sidewall Fast response K Factor K=5.8 (80.6) Օ 3 mm bulb type Tnread Si/e 1/2' (15 mm) Used in wet pipe residential sprinkler Systems for one- and two-family dwellings and mobile homes per Escutcheon Stvle20 NFPA 130 Օ Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R Finish Brass, Chrome, Whrte Tech Data TFP415 Used in wet pipe spnnkler Systems for the residential portions of any occupancy per NFPA 13 MAXIMUM MAXIMUM COVERAGE AREA SPAONG MINIMUM FLOW & RESIDUAL PRESSURE ft x ft (m x m) Mm) 4'-6* <10?...

 Open the catalog to page 9
rapid response Home Fire Sprinkler System-10

BlazeMaster® CPVC Pipe & Fittings The RapidResponse Home Fire Sprinkler System features CPVC Pipe and Fittings manufactured with Lubrizol's BlazeMaster* compound- listed by Underwriters Laboratories, Inc. (or use in: Light hazard occupantes as defined in the Standard for Installation of Fire Sprinkler Systems, NFPA 13 Օ Rsidentiel occupancies as defined in the Standard for Installation of Fire Sprinkler Systems in Rsidentiel Occupancies up to Four Stories in Height, NFPA 13R 驕 Rsidentiel occupancies as defined in the Standard for Fire Sprinkler Systems in One- and Two-Famify DwelHngs and Manufactured...

 Open the catalog to page 10
rapid response Home Fire Sprinkler System-11

Install With Confidence Tyco BlazeMastef* CPVC Piping Systems are UL- and cUL-listed, FM opproved. and exceed ASTM standards. Benefits over traditional piping Systems include: Rթsistant to rust, scale and foreign contaminant burldup Supenor llow charocteristics (or increased hydreulic capabilities (C-Factor«150) Օ Easity transported, handled and modified on site Can be easily connected to copper and steel pi ping Օ Resist sweating and condensation Immune to Microbiologically Influenced Corrosion (MIC) BACK-TO BACK CROSS SPRINKLER HEAD ADAPTER SPIGOT SPRINKLER HEAD ADAPTER (SUPXF1PT) Fire...

 Open the catalog to page 11
rapid response Home Fire Sprinkler System-12

System Components Residential Domestic Shutoff Valve 1" (25.4 mm) is used in piping Systems that supply water to both domestic service and the fire sprinkler system designed per NFPA 13D or 13R in one/two-family dwellings and mobile homes Օ In the set position, water is available on demand to the domestic system, and the valve acts as a check valve for the fire protection system When a sprinkler operates, the supply to the domestic system is automatically shut off, maximizing the available water supply for fire protection Օ Eliminates the need for expensive pumps, pressurized tanks, or electrically...

 Open the catalog to page 12
rapid response Home Fire Sprinkler System-13

"Butterball" Butterfly Valves Ideal for use in residential sprinkler Systems as main control valves Օ An alternative to bulky OS&Y valves Mandated visual indicator showing that the valve is open or closed Available from 1" through 2-1/2" Electric Alarm Bell Ideally suited for residential applications Օ Unobtrusive to the homeowner, yet absolutely dependable in a fire event When used with a flow switch, if water flow occurs in a sprinkler system protecting residential occupancies, an audible alarm sounds to alert the occupants and neighbors of trouble Sprinkler Head Cabinet Spare sprinkler...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.