Model BFV-300/BFV-300C Butterfly Valve Grooved End - 1

Worldwide www.tyco-fire.com Contacts Model BFV-300/BFV-300C Butterfly Valve Grooved End General Description Technical Data The TYCO Models BFV-300 and BFV300C Grooved End Butterfly Valves are indicating type valves designed for use in fire protection systems where a visual indication of open or closed valve condition is required. They are used, for example, as system, sectional and pump water control valves. They have grooved inlet and outlet connections that are suitable for use with grooved end pipe couplings listed or approved for fire protection systems. For applications requiring supervision of the open or closed state of the valve, the Gear Operators for the Model BFV-300/BFV-300C Butterfly Valves feature two sets of factory installed internal switches each having SPDT contacts, see Figure 3. The supervisory switches transfer their electrical contacts when there is movement from the open or closed disc position during the first two revolutions of the handwheel. Note: If the butterfly valve is required in a foam system, verify the valve is compatible by referring to the foam concentrate manufacturer technical literature for information about foam compatibility, and acceptable system equipment materials of construction. NOTICE The Model BFV-300 /BFV-300C Grooved End Butter fly Valves described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. Contact the installing contractor or product manufacturer with any questions. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. UL and ULC Listed FM Approved CE Certified VdS Approved Russian Fire Certificate CNPP R1 Listed – APSAD Listed by California State Fire Marshall For specific information about approvals, see Tables A, B, and C. Note: All laboratory listings and approvals are for indoor and outdoor use. MODEL BFV-300 OPEN SUPERVISORY SWITCHES UL/ULC/FM Maximum Working Pressure VdS Maximum Working Pressure Maximum Working Temperature Body ��������������������������������������������������Ductile Iron Body Coating ���������������������� RILSAN PA11 Black Disc ����������������������������������������������������Ductile Iron Disc Seal. . . . . . . . . . . . . . . EPDM Encapsulated Upper & Lower Stem �������������������� Stainless Steel Handwheel ����������������������������������������Ductile Iron (BFV-300 red painted; BFV-300C black painted) Actuator, 2 in.–6 in. (DN50–DN150): • IP65, bronze traveling nut gearbox, ductile iron housing Actuator, 8 in.–12 in. (DN200–DN300): • IP65, brass segmented gearbox, ductile iron housing MODEL BFV-300C CLOSED SUPERVISORY SWITCHES Silicone Free Model Availability Silicone free models are available. Contact TYCO sales for information. Tapping Bosses Two factory-plugged NPT threaded tapping bosses i

Open the catalog to page 1
Model BFV-300/BFV-300C Butterfly Valve Grooved End - 2

TFP1511 Page 2 of 8 Nominal Dimensions Inches (mm) Nominal Valve Size Inches (DN) INDICATOR FLAG (VALVE CLOSED) SEGMENTED GEAR OPERATOR 8 TO 12 INCH (DN200 TO DN300) VALVE SIZES INDICATOR FLAG (VALVE OPEN) TAPPING BOSSES DISC ELECTRICAL CONNECTOR TRAVELLING NUT GEAR OPERATOR 2 TO 4 INCH (DN50 TO DN100) VALVE SIZES FIGURE 1 MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE NOMINAL DIMENSIONS TRAVELLING NUT GEAR OPERATOR 5 TO 6 INCH (DN125 TO DN150) VALVE SI

Open the catalog to page 2
Model BFV-300/BFV-300C Butterfly Valve Grooved End - 3

Bolt (Round) Material ASTM A-228 ASTM A-619 Upper Stem Lower Stem Material ASTM A-167 ASTM A-167 Plate Washer Switch Assembly Cover Gasket Worm Shaft Traveling Nut 2–6 Inch Segment Gear 8–12 Inch Spring Washer ASTM A-167 ASTM A-167 ASTM A-167 Headless Wrench Bolt M5 x 7L Stem Housing Headless Plug 3/8 NPT 2–3 Inch 41 Headless Plug 1/2 NPT 4–12 Inch BFV-300 Normally Open Valve Supervisory Switch Arrangement BFV-300C Normally Closed Valve Supervisory Switch Arrangement

Open the catalog to page 3
Model BFV-300/BFV-300C Butterfly Valve Grooved End - 4

FLOW RATE IN LITERS PER MINUTE (LPM) (1 GPM = 3,785 LPM) 1000 2000 4000 6000 NOMINAL PRESSURE DROP IN BAR (1 PSI = 0,06895 BAR) NOMINAL PRESSURE DROP IN POUNDS PER SQUARE INCH (PSI) 200 400 600 800 1000 FLOW RATE IN GALLONS PER MINUTE (GPM) GRAPH A MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE NOMINAL PRESSURE DROP VERSUS FLOW YELLOW COMMON (WHITE) COMMON (WHITE) MODEL BFV-300/BFV-300C GEAR OPERATOR FIRE ALARM CONTROL PANEL SUPERVISORY CIRCUIT CONTACT RATINGS: 16A 125V/250 VAC 5A 24VDC SWITCH S-1, 2 LEADS PER CONTACT SWITCH S-2, 1 LEAD PER CONTACT VOLTAGE SOURCE COMMON (BLACK) END OF...

Open the catalog to page 4
Model BFV-300/BFV-300C Butterfly Valve Grooved End - 5

Part Number BFV-300 BFV-300C Supv. Switch Supv. Switch OPEN CLOSED Agency Listing/Approval Russian CA Fire CE UL ULC FM VdS Marshall CNPP PAVUS Fire Cert. TABLE A MODEL BFV-300/BFV-300C GROOVED END BUTTERFLY VALVE WITH INTERNAL SUPERVISORY SWITCHES PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS Nominal Valve Size Inches (DN) 2 (DN50) 2-1/2 (DN65) — DN65 3 (DN80) 4 (DN100) — DN125 5 (DN125) — DN150 6 (DN150) 8 (DN200) 10 (DN250) 12 (DN300) Part Number BFV-300 BFV-300C Supv. Switch Supv. Switch OPEN CLOSED

Open the catalog to page 5
Model BFV-300/BFV-300C Butterfly Valve Grooved End - 6

Agency Listing/Approval Part Number Russian CA Fire CE UL ULC FM VdS Marshall CNPP PAVUS Fire Cert. ✓ TABLE C MODEL BFV-300 GROOVED END BUTTERFLY VALVE WITHOUT INTERNAL SUPERVISORY SWITCHES PART NUMBER SELECTION AND AGENCY LISTINGS/APPROVALS Nominal Valve Size Inches (DN) Part Number Gear Operator Type Mounting Bracket with Mounting Bolts Bernstein i88-IP65 Regular Switch Bernstein GC-SU1Z Ex IP-66/67 ATEX (Ex II2G Ex dIIC T6 Gb) Switch Notes: 1. Install a single switch in either bracket mounting position to monitor Open or Closed valve condition

Open the catalog to page 6
Model BFV-300/BFV-300C Butterfly Valve Grooved End - 7

Installation The Model BF V-300 / BF V-300C Grooved End Butterfly Valves may be installed with flow in either direction and can be positioned either horizontally or vertically. The grooved end pipe couplings used with the Model BFV-300/BFV300C must be listed or approved for fire protection service and installed in accordance with the manufacturers instructions. The Model BFV-300/BFV-300C Butterfly Valve may be installed with any schedule of pressure class of pipe or tubing that is listed or approved for fire protection. Conduit and electrical connections are to be made in accordance with...