Overview: The document provides comprehensive information about Tyco Fire & Building Products, a leader in fire suppression systems for special hazard risks. It covers the types of hazards, product offerings, and systems designed to mitigate these risks.
Special Hazards: Special hazards refer to areas or equipment that standard sprinkler systems cannot adequately protect, such as flammable liquid storage and critical process equipment. The document stresses the importance of identifying these hazards and implementing suitable protection systems.
Product Offerings: Tyco offers over 250 fire protection items and 1,200 components for system fabrication, including sprinklers, nozzles, and valves. The company is dedicated to research and development to address current and future market needs.
System Types: The document details various fire protection systems:
  • Nozzles & Accessories: Designed for special hazards, including Protectospray®, MULSIFYRE®, and high-velocity spray nozzles.
  • RED-E CABINET®: Integrated fire protection packages with preassembled riser assemblies and electrical controls, available in deluge, single, and double interlock preaction configurations.
  • Single Interlock Preaction Systems: Used where water damage from accidental sprinkler activation is a concern, requiring a fire detection system to activate the deluge valve.
  • Double Interlock Preaction Systems: Provide maximum protection against accidental operation, requiring both a loss of air pressure and activation of a fire detection device.
Technical Specifications: Includes technical data for nozzles and systems, specifying K factors, thread sizes, finishes, and approval listings. Emphasizes consulting technical data sheets for installation and maintenance.
Approvals and Listings: Tyco's products are listed and approved by various fire protection organizations, ensuring compliance with industry standards.
Customer Service and Distribution: Tyco serves a diverse group of specifiers and distributes products through strategically located facilities and independent distributors for quick delivery.
Deluge Valves: Automatic water control valves used in systems like deluge and preaction, crucial for areas needing full water application. Details models (DV-5, DV-1, DV-3) with specifications like size, installation type, and pressure ratings.
Trim Assemblies: Lists trim assemblies for wet pilot, dry pilot, and electric actuation, specifying compatibility with deluge valve models.
AquaMist Systems: Use advanced nozzles for fire protection, offering an alternative to traditional systems by using less water at higher pressures. Effective in reducing water damage and costs, emphasizing efficiency in heat extraction and oxygen displacement.
Nozzle Specifications: Provides specifications for AquaMist nozzles, including coverage area, pressure ratings, and approvals, highlighting their use in protecting flammable liquids and gas turbines.
Contact Information: Includes contact details for Tyco Fire & Building Products' headquarters and regional offices worldwide.
See more

Catalog excerpts

 Fire Protection Systems-2

Tyco Fire & Building Products is a leading manufacturer and distributor of water-based fire suppression systems and components for special hazard risks, offering one of the broadest lines of fire protection system equipment worldwide for Special Hazard Systems to meet your needs. Our complete line of standard sprinklers have a fantastic record of performance, consistency, and dependability. However, many plants and buildings contain fire hazards that standard automatic sprinklers cannot control or extinguish. These are termed "Special Hazards". In general, a special hazard is an area, process,...

 Open the catalog to page 2
 Fire Protection Systems-4

Breadth of Line Tyco Fire & Building Products (TFBP) offers more than 250 fire protection products and over 1,200 items used in the fabrication of fire protection systems, including sprinklers, nozzles, valves, devices, CPVC pipe, fittings and hangers, and sprinkler system accessories. Research and Development TFBP is backed by one of the largest research, design, development group and facilities in the industry. Our experienced staff of engineers is continually working to develop new types of sprinklers and valves, as well as special hazard fire protection devices to fill present and future...

 Open the catalog to page 4
 Fire Protection Systems-5

Power Plants Chemical Plants Offshore Platforms Aircraft Hangars Cooling Towers Computer Rooms Switchgear Rooms Transformers Wet Benches Ammunition Plants Engine Test Cells LPG Storage Spray Paint Booths Battery Rooms Oil Quenching Pits Petrochemical Storage Records Vaults Electronic/Telephone Rooms Solvent Tanks and Storage Shipboard Machinery Rooms Flammable Liquid Storage Hydraulic Oil, Lubricating Oil Rooms Tank Farm/Truck Loading Facility Ss3 J 0 5

 Open the catalog to page 5
 Fire Protection Systems-6

Nozzles & Nozzle Accessories are designed for use in a variety of spcial hazards applications. Their uses include, but are not limited to, exposure protection, fire control, fire extinguishment, and explosion prevention. Many types of nozzles may be required to provide a properly designed special hazard fire protection system. D-3 K Factor K=1.2 (17,3) K=1.8 (25,9) K=2.3 (33,1) 镕 K=3.0 (43,2) K=4.1 (59,0) K=5.6 (80,6) K=7.2 (108,7) Thread Size 1/2"" (15 mm) Finish Natural brass, chrome plated, electroless nickel plated, lead coated or Teflon coated. Stainless steel, plain only. Tech Data TD620A...

 Open the catalog to page 6
 Fire Protection Systems-7

F822 through F834 Mulsifyre® Nozzles K Factor K=2.3 (33,1) K=2.6 (37,4) K=2.7 (38,9) Օ K=4.6 (66,2) K=5.1 (73,4) Thread Size 3/4" (20 mm) Finish Natural Brass, Chrome Plated Tech Data TD675 Օ Designed to discharge a filled cone of water droplets at a relatively high velocity Used in either open or water primed systems Օ A blow-off cap is available with the nozzle for a primed system (chrome plated finish only) UL, ULC, FM Օ Open, internai scroll type nozzles Six different orifice sizes and spray angles afford a variety of design options HV "High Velocity" Spray Nozzles K Factor K=1.6 (23,0)...

 Open the catalog to page 7
 Fire Protection Systems-8

Cooling Tower Nozzles Type 1 and 2 K Factor K=2.9 (41,8) Thread Size 3/4" (20 mm) Tech Data TD730 Installed under the distribution basin, they discharge water in a relatively narrow, elongated spray pattern Օ Type 1 has a waterway designed for use in towers with diffusion decks, Type 2 for those without diffusion decks UL, FM Intended for use in fire protection Systems for cross flow cooling towers with combustible fill sections Open nozzle design for use in water spray deluge system F800 Nozzles K Factor K=1.8 (26,0) K=2.6 (37,4) K=4.1 (59,0) Specifically designed to spray a water pattern...

 Open the catalog to page 8
 Fire Protection Systems-9

Red-E Cabinet® Integrated Fire Protection Packages Tech Data TD1110 Can be piped from either side for supply and drain functions Օ Discharge is vertical Available with DV-1, DV-3, and DV-5 valves Օ Listings and Approvals: All components - UL, C-UL, ULC, and FM Complըte riser assembly enclosed within a free-standing cabinet Package is preassembled with all trim installed and electric switches prewired, making the connections for power, local, remote alarms, and other external electrical functions the only electrical connections needed to complete the installation Օ Cabinet is constructed from...

 Open the catalog to page 9
 Fire Protection Systems-10

Single Interlock Preaction Systems Electric Shown Single interlock preaction Systems are used to protect areas where there is danger of serious water damage that might result from damaged automatic sprinklers or piping. Typically, such areas include computer rooms, storage areas for valuable artifacts, libraries and archives. Also, preaction systems are effectively used to protect properties where a prealarm of a possible fire condition may allow time for fire extinguishment by alternate suppression means, prior to a sprinkler discharge. In the event the fire cannot otherwise be extinguished,...

 Open the catalog to page 10
 Fire Protection Systems-11

Double Interlock Preaction Systems Pneumatic/Electric Shown Double interlock preaction Systems are designed for applications such as refrigerated areas that require the maximum degree of protection against an inadvertent operation that could result in unnecessary flooding of the sprinkler system piping. The double interlock system consists of a deluge valve and swing check valve with releasing trim featuring both a solenoid valve and a dry pilot actuator in a series configuration. The swing check valve isolates the body of the deluge valve from the system air or nitrogen pressure that holds the...

 Open the catalog to page 11
 Fire Protection Systems-12

Dluge Valve & Dluge Systems Electric Shown The "d驩luge valve" is the automatic water control valve that is used to control water flow into deluge, preaction, and special types of fire protection systems in response to a fire. Deluge fire protection systems are normally used in special hazard installations where an entire area application of water is required for protection. Typical applications may include flammable liquid handling and storage areas, aircraft hangars, and other high- hazard installations where water is the most effective extinguishing agent. Deluge systems employ open sprinklers...

 Open the catalog to page 12
 Fire Protection Systems-13

DV-5 Dluge Valve, External Resetting Diaphragm Style - 1-1/2" through 8" Tech Data TFP1305 ■ Features external resetting Diaphragm operation For most seawater & brackish water supplies for deluge systems For deluge, preaction & foam systems Available as Flange x Flange, Flange x Groove, or Groove x Groove body styles Rated for 250 psi (17,2 bar) service Listings and Approvals: UL, C-UL, and FM Available sizes:1-1/2" (DN40), 2" (DN50), 3" (DN80), 4" (DN100), 6" (DN150), 8" (DN200) Vertical or horizontal installation One internal working part No linkage or clapper assembly Light weight ductile...