T Series Encoders with CANopen Interface User Manual TWK-ELEKTRONIK GmbH · PB. 10 50 63 · D-40041 Düsseldorf
Open the catalog to page 1COPYRIGHT: The TXN 11551 operating instructions are owned by TWK-ELEKTRONIK GMBH and are protected by copyright laws and international treaty provisions. © 2009 by TWK-ELEKTRONIK GMBH POB 10 50 63 ■ 40041 Dusseldorf ■ Germany Tel. +49/211 /63 20 67 ■ Fax +49/211 /63 77 05 info@twk.de ■ www.twk.de
Open the catalog to page 21. General The electromagnetic T Series encoders are designed for direct connection to the CAN bus. This is achieved internally via the CAN bus controller T89C51 CC02 SO 28 (Atmel). The following specifications have been implemented: Device Profile for Encoders CiA Draft Standard 406, Version 3.0 /1/ CANopen Application Layer and Communication Profile CiA Draft Standard 301, Version 4.02 /2/ The CANopen specifications can be obtained from the user organisation CiA (www.can-cia.org). The following T Series encoders with CANopen interface have been taken into consideration: 2. CANopen...
Open the catalog to page 53. Installation instructions 3.1 Electrical connection CiA Draft Recommendation Proposal 303-1, Version 1.1.1 CANopen Cabling and Connector Pin Assignment /3/ must be adhered to when connecting the encoder. This particularly applies with regard to the terminal resistors, the lead characteristics, the length of the branch lines and the transmission length. The bus terminal resistors must be implemented internally. The precise connector assignment is enclosed with each device. Principle bus structure: 3.2 Baud rates and lead lengths Note: The encoder has no galvanic separation between the...
Open the catalog to page 64. Process data exchange In the case of CANopen, I/O data traffic takes place via the PDO (Process Data Object) message. The T Series encoders provide two PDOs. Their transmission behaviour (transmission type) can be set independently of each other. 4.1 Operating modes The following operating modes can be set: Polling Mode (asynchronous-RTR): The encoder transmits the current, actual position value, after the current position value has been polled via a „Remo-te Frame“ message by the master. Asynchronous Mode (cyclic / acyclic): Without being requested to do so by the master, the encoder...
Open the catalog to page 74. Process data exchange 4.2 Data format The definition of the output data (mapping) and their depiction is identical for both PDOs. The position value is output in steps and, in the case of the variant with speed signal, the speed value is output in steps per 100 ms. The position and speed value can also be called up in the object directory under indices 6004h - Position value and 2010h - Speed value. The position and speed values are depicted in Intel format. The following tables show encoders with 13 bits single turn resolution. For encoders with 12 bit resolution the positi-onvalue is...
Open the catalog to page 85. Emergency messages Each time the internal error status register (Index 1001 h) changes, the encoder transmits an emergency message with the identifier: 80h + node ID (even if an error which has occurred has been rectified). An emergency message is comprised of 8 data bytes and is structured as follows:
Open the catalog to page 96. Programming and diagnosis (object directory) 6. Programming and diagnosis (object directory) In the case of CANopen, all parameters and diagnostic information are contained in the object directory. There, they may be changed and/or read with the SDO (Service Data Object) message, specifying their index and sub-index. The object directory is sub-divided into the following areas: Communication parameters Index 1000h - 1FFFh Manufacturer-specific parameters Index 2000h - 5FFFh Standardised device parameters Index 6000h - 9FFFh Those parameters marked with “rw” in this chapter can be set by...
Open the catalog to page 106.2 Communication parameters 6.2.1 Object 1000h - Device type Contains the manufacturer software version, e.g.: „TBN Std“
Open the catalog to page 116. Programming and diagnosis (object directory) 6.2.7 Object 1010h - Store parameters The information in object 1018h (also see Chapter 3.3) is required to use the Layer Setting Service (LSS, /5/).
Open the catalog to page 126.2.13 Object 1800h - First transmit PDO
Open the catalog to page 136. Programming and diagnosis (object directory)
Open the catalog to page 146.3 Standardised device parameters 6.3.1 Object 6000h - Operating parameters Values in brackets represent an encoder with 13 bit single turn resolution. The „Scaling function control" bit (object 6000h) must be enabled in order to change the parameter.
Open the catalog to page 156. Programming and diagnosis (object directory) Note: For parametration of TRN it must be noted that the calculation of the number of revolutions is carried out in 2n powers internally within the encoder. Regardless of this requirement, the user may programme the desired total measuring range in units and the desired single turn resolution in accordance with the application. During calculation, the encoder accesses the next highest 2n power if required. In this case, the values are designated as the actual single turn resolution or as the actual total measuring range in units, and are...
Open the catalog to page 166.4 Standardised device diagnosis 6.4.1 Object 6500h - Operating status Only the alarms listed under object 6503h are supported.
Open the catalog to page 176. Programming and diagnosis (object directory) 6.4.6 Object 6506h - Supported Warnings The object contains the device‘s serial number.
Open the catalog to page 186.5 Manufacturer-specific parameters 6.5.1 Object 2000h - Node ID Gate time for speed measurement in ms. The updating time of the speed signal is equal to the gate time.
Open the catalog to page 197. Examples Message traffic between a master and the TBN encoder (single-turn encoder without speed signal) during boot-up and when setting the slave address with LSS is shown in the following. The identifier (ID), the transmission direction (Rx/Tx), the Data Length Code (DLC) and the data bytes are shown in tabular form. The following applies: - The encoder has the address 1 (default) and is the only slave - Encoder with default parameter values - Tx: Master transmits data to the encoder - Rx: Encoder transmits data 7.1 Boot-up The following Table shows encoder boot-up, from switching on...
Open the catalog to page 20All TWK-ELEKTRONIK GmbH catalogs and technical brochures
-
Rotary encoder TBN58/C3 manual
50 Pages
-
Rotary encoder TBN58/C3
22 Pages
-
Rotary encoder TBD Manual
26 Pages
-
Rotary encoder TBD
12 Pages
-
Rotary encoder TBE58
16 Pages
-
Rotary encoder KRP - Manual
19 Pages
-
Rotary encoder KRP
7 Pages
-
Rotary encoder TBN58/S4 SIL2
22 Pages
-
Rotary encoder TBN50/C3 manual
20 Pages
-
Rotary encoder TBN50/C3
22 Pages
-
Rotary encoder HBN/S3 SIL2
16 Pages
-
Product range 2022
64 Pages
-
Image brochure TWK
28 Pages
-
Inclinometer NBA51
6 Pages
-
Incremental encoder FOI
7 Pages
-
Rotary encoder TBA42
16 Pages
-
Rotary encoder TRA42
16 Pages
-
Rotary encoder TRN58/S4 SIL2
22 Pages
-
Rotary encoder TRN58/C3 manual
50 Pages
-
Rotary encoder TRN58/C3
22 Pages
-
Rotary encoder TRN42/S4 SIL2
22 Pages
-
Manual TRN50/C3
86 Pages
-
Rotary encoder TRN50/C3
22 Pages
-
Rotary encoder TRN42/C3 manual
86 Pages
-
Rotary encoder TRN42/C3
22 Pages
-
Rotary encoder TBN42/S4 SIL2
22 Pages
-
Rotary encoder TBN42/C3 manual
86 Pages
-
Rotary encoder TBN42/C3
22 Pages
-
Rotary encoder TRE58
16 Pages
-
Rotary encoder TRT manual
40 Pages
-
Rotary encoder TRT
14 Pages
-
Switching cam encoder NOCE
14 Pages
-
Switching cam encoder NOCA
17 Pages
-
Vibration sensor NVT/S3 PLd
12 Pages
-
Vibration sensor NVA
12 Pages
-
Inclinometer NBN
17 Pages
-
Incremental encoder TBI42
6 Pages
-
Vibration sensor NVA/S3 PLd
15 Pages
-
Rotary transducer PMR411
1 Pages
-
Rotary encoder TRT/S3 SIL2
13 Pages
-
Rotary transducer VP12
1 Pages
-
Switching cam encoder NOCN
22 Pages
-
Inclination sensor NBT manual
21 Pages
-
Inclination sensor NBT
10 Pages
-
Inclinometer NBA
17 Pages
-
Inclinometer NBT/S3 SIL2/PLd
12 Pages
-
Inclinometer NBN/S3 SIL2
13 Pages
-
Rotary encoder TBE50
16 Pages
-
Rotary encoder HBE
14 Pages
-
Rotary encoder TRK manual
18 Pages
-
Rotary encoder TRK
11 Pages
-
Rotary encoder TMN50 manual
22 Pages
-
Rotary encoder TMN50
6 Pages
-
Rotary encoder TRK/S3 SIL2
14 Pages
-
Rotary encoder TRE42
6 Pages
-
Rotary encoder TRE50
6 Pages
-
Rotary encoder TRA50
6 Pages
-
Rotary encoder TBE42
6 Pages
-
Rotary encoder TME42
6 Pages
-
Rotary encoder TRD manual
26 Pages
-
Rotary encoder TRD
12 Pages
-
Rotary encoder TME50
6 Pages
-
Rotary encoder TBN36
6 Pages
-
Rotary encoder TMA50
6 Pages
-
Rotary encoder TMN42
6 Pages
-
Rotary encoder TMA42
6 Pages
-
Rotary encoder TBA50
16 Pages
-
Rotary encoder TBE36 manual
22 Pages
-
Rotary encoder TBE36
6 Pages
-
Rotary encoder TBN42
6 Pages
-
Rotary encoder TBN37
8 Pages
-
Rotary encoder TBA37
7 Pages
-
Rotary encoder TBB50
16 Pages
-
Rotary encoder PBA12
2 Pages
-
Rotary encoder TBA36
6 Pages
-
Rotary encoder TKA60
2 Pages
-
Rotary encoder TKN46 manual
22 Pages
-
Rotary encoder TKN46
7 Pages