Magnetostrictive displacement transducer MPA
3Pages

{{requestButtons}}

Catalog excerpts

Magnetostrictive displacement transducer MPA - 1

MAGNOSENSMagnetostrictive Displacement Transducers Model series MPA / MSA: Analogue output, programmable ■ MPA model: Profile version ■ MSA model: Rod version ■ Measuring strokes from 50 to 7600 mm ■ Contactless, robust system ■ Resolution 0.0015% (16-bit) ■ Linearity 0.01% ■ Option: 2 position magnets or speed signal ■ Measurement signals 0(4) ... 20 mA, 0 ... 10 V or ± 10V ■ Protection types up to IP 68 ■ Operating temperature range - 40 °C ... + 75 °C ■ Rod version pressure stability up to 350 bar Structure and operation The displacement transducers operate according to the principle of run time measurement between two points of a magnetostrictive waveguide. One point is determined by a moveable position magnet, whose distance from the null point corresponds to the section to be measured. The run time of an emitted impulse is directly proportionate to this section. Conversion to an analogue measuring signal takes place in the downstream electronics. The waveguide is housed in a pressure-resistant stainless steel tube or extruded profile. To the rear of this is a die-cast aluminium housing containing the electronics in SMD technology. Electrical connection is implemented via a circular connector. In the rod version, the position magnet is located in a ring, which is guided over the rod without contact. In the profile version, it is located either in a slider, which is linked to the moving part of the machine via a ball joint, or it moves as a liftable position magnet, without wear, over the profile. Standard measuring strokes: □ Up to 1000 mm in 50 mm steps □ Up to 5000 mm in 250 mm steps (profile version: MPA) □ Up to 7600 mm in 250 mm steps (rod version: MSA) TWK-ELEKTRONIK GmbH ■ PB. 10 50 63 ■ D-40041 Dusseldorf ■ Tel.: +49/211/63 20 67 ■ Fax: +49/211/63 77 05 ■ info@twk.de ■

Open the catalog to page 1
Magnetostrictive displacement transducer MPA - 2

Technical data Order code format ■ Supply voltage range VS: ■ Supply current IS: ■ Resolution: ■ Linearity: ■ Repeatability: ■ Hysteresis: ■ Measuring frequency: ■ Temperature drift: ■ Operating temperature range: ■ Shock test: ■ Vibration test: ■ Protection type: □ Profile: □ Rod: ■ Current output: ■ Output signal: ■ Apparent ohmic resistance: ■ Voltage output: ■ Output signal: ■ Permissible load: 24 VDC (+20 / -15%) 100 mA typical 16-bit; 0.0015% (min. 1 pm) < ± 0.01% (min. ± 50 pm) < ± 0.001% (min. ± 1 pm) < 4 pm 500 to 2000 Hz depending on measuring length < 30 ppm / °C - 40 °C to + 75...

Open the catalog to page 2
Magnetostrictive displacement transducer MPA - 3

Magnetostrictive Displacement transducers MPA / MSA Dimensions in mm Threaded connection Model: MSA (rod version) Sensor head Position ring Measuring range Installation zone With measuring strokes of 1000 mm and over, mechanical rod support is recommended. The sensor’s fastening should be manufactured from non-magnetic materials (e.g.: brass, plastic). Note installation instruction MWA10318 on installation in magnetisable materials. Option: Cable outlet Model: MPA (profile version) Front ball joint PS02 Central ball joint PS01 Damping zone Sensor head Metal connector Liftable position...

Open the catalog to page 3