Catalog excerpts
TECHNICAL SPECIFICATION 44 and 55 Compact Sterilizer Series FEATURE SUMMARY DEVICE PICTURE Chamber volume from 120 to 310 liters Working pressure meets ASME and PED requirements Temperature range 105 °C (221 °F) to 138 °C (280 °F) 18 kW / 27 kW integral steam generator or external steam source User friendly control system with touch screen display 30 Programs: 8 factory set programs, 2 test programs, 20 programmable cycle programs Built-in printer Ethernet connection port for PC access via network USB port to download cycle data to memory device Pressure gauges on front panel 316L stainless steel chamber and door Chamber has a mirror-like finish Stainless steel piping Conforms to Medical Device Directive 93/42 EEC and PED 97/23 EC, FDA Clearance Conforms to standards: ASME, AAMI/ANSI-ST8, EN 285, UL Company approved for 21 CFR 820, ISO 9001:2008 and ISO 13485:2003 (Medical Devices) Optional configurations available 44 Compact Series with Hinged Door PRODUCT DESCRIPTION This autoclave series is designed to cover a large field of applications for hospitals, CSSD and medical centers. The autoclave series has a chamber volume range from 120 liters to 310 liters. The autoclave operates with saturated steam as the sterilizing agent with a temperature range from 105 °C (221°F) to 138 °C (280 °F) and a working pressure that meets ASME and PED requirements. The autoclave is equipped with an 18kW and 27kW integral electrical steam generator which supplies the necessary steam for the sterilization process. The sterilizer may also be steam fed from an external steam source. APPLICATIONS Central Sterilizing Supply Department (CSSD) Operating Theater Out Patient Clinic Information furnished by Tuttnauer is believed to be accurate and reliable. However, no responsibility is assumed by Tuttnauer for its use. This specification is subject to change without notice. 44 Compact Series with Vertical Sliding Door Tuttnauer - Your Sterilization & I
Open the catalog to page 1TECHNICAL SPECIFICATION 44 and 55 Compact Sterilizer Series PRODUCT SPECIFICATION VOLTAGE SUPPLY CHAMBER VOLUME & SIZE Voltage: 415V 3-Phase with Neutral 380V / 400V 3-Phase with Neutral 230V 3-Phase with Neutral 208V 3-Phase with or without Neutral 220V / 230V 1-Phase (not 55120 model) 110V / 115V 1-Phase * Three phase or one phase electricity supply is available. VOLUME (liter) * For 18kW with building steam supply (optional vacuum by ejector) 50 Hz or 60 Hz STEAM GENERATOR POWER (kW) DOOR SELECTION Single door Double door (pass through) Manual right hinged Manual left hinged...
Open the catalog to page 2TECHNICAL SPECIFICATION 44 and 55 Compact Sterilizer Series CHAMBER CONSTRUCTION Materials The sterilizer chamber is constructed from solid, high quality materials. Chamber and door thickness is no less than 5 mm. Standard Configuration Materials: Chamber + Door: 316L stainless steel Jacket: 304L stainless steel Optional Materials (Stainless Steel): Chamber + Door: 316Ti Jacket: 316L or 316Ti Chamber Design The chamber is fully jacketed. A stainless steel mesh strainer protects the drain port from blockage by debris. The chamber is mounted on a steel framework which is height adjustable....
Open the catalog to page 3TECHNICAL SPECIFICATION 44 and 55 Compact Sterilizer Series AIR FILTER A disposable microbiological air filter is provided to filter all air entering the sterilizer chamber. The air is used to equalize the chamber pressure to atmospheric pressure at the end of the sterilization cycle. The filter is rated for a particle size of 0.2 µm. CONTROL SYSTEM (ALLEN-BRADLEY) The controls system is based on the Allen Bradley MicroLogix 1400 PLC platform, and controls and monitors the physical parameters of the sterilization process, and performs the operation sequence of the machine, according to the...
Open the catalog to page 4TECHNICAL SPECIFICATION 44 and 55 Compact Sterilizer Series CONTROL PANEL The autoclave uses both audible and visual alarm indicators. Automatic process checking and failure detection are provided by the control system. In the event of a failure during the sterilization cycle, the system enters an alarm phase which will safely end the process automatically. The range of alarms includes: The control system is operated via an easy to use full color touch screens (7” TFT LCD) found on both sides of the autoclave. One or both touch screens may be upgraded to 10” display. The touch screen...
Open the catalog to page 5TECHNICAL SPECIFICATION 44 and 55 Compact Sterilizer Series STERILIZER DOCUMENTATION A number of copies of the manuals are provided. Operator and service manuals are in selected language. Other manuals are in English. Manuals include electrical and piping diagram. Furthermore, a CD is provided containing the following: Operators manual Technical manual Serial number for specific autoclave Factory test report prior to shipping Optional - technical specifications for component, etc. MAINTENANCE / SERVICE PLAN A global network of skilled service specialists can provide periodic...
Open the catalog to page 6TECHNICAL SPECIFICATION 44 and 55 Compact Sterilizer Series UTILITY DATA / REQUIREMENTS External Steam Source 1. 97 – 100 % dry saturated steam 2a. Steam rate 46 kg/h for 6690, 66120, and 6671130 models 2b. Steam rate 80 kg/h for 6671162 Model 3. Protected by certified safety valve - max. 2.8 bar 4. Final steam pipe to the autoclave at least pipe 1" diameter 5. Install a shut-off valve at end of steam pipe Electrical With generator (all models) 3-Phase, 208 / 220 / 230 / 380 / 400 / 415 Volt, with or without neutral, 18 kW For autoclave model 55120: 3-Phase, 208 / 220 / 230 / 380 / 400...
Open the catalog to page 7TECHNICAL SPECIFICATION 44 and 55 Compact Sterilizer Series PROGRAM CYCLE DATA Program 1 - Warm Up Atmospheric Pressure Atmospheric Pressure Atmospheric Pressure Unwrapped rigid (instruments), etc. Parameters Units Range Factory Setting 1. Sterilization Temperature ºC 105 - 138 121 2. Sterilization Time min 1 - 99 15 3. Exhaust Mode 1-6 1 (fast) 4. Drying Time (Post-Vacuum) min 0 - 99 1 Notes: Residual air is displaced by 4 vacuum pulses (down to 25 kPa) and 3 steam pulses up to 160 kPa. When the pressure reaches atmospheric pressure, the vacuum pump is activated until the pressure drops to...
Open the catalog to page 8All Tuttnauer catalogs and technical brochures
-
T-Edge10
12 Pages
-
tvet 9Mi
6 Pages
-
500/800 Models
2 Pages
-
Laboratory Line
16 Pages
-
5596
12 Pages
-
D-Line | Tabletop Autoclaves
12 Pages
-
Clinic Washer-Disinfectors
8 Pages
-
GS Hospital Autoclaves
8 Pages
-
EL - D LINE MODELS
16 Pages
-
3870HSG D-Line
8 Pages
-
Tiva 600 Lab
8 Pages
-
BSL3 and BSL4 Autoclaves
12 Pages
-
Pharmaceutical Autoclaves
16 Pages
-
Water Distiller
2 Pages
-
Ultrasonic Cleaning System
2 Pages
-
Medical Waste Autoclaves
12 Pages
-
Elara 9D
8 Pages
-
Bedpan Washers
4 Pages
-
T-Max Hospital Autoclaves
12 Pages
-
Bulk Autoclaves
8 Pages
-
Animal Care Large Autoclaves
12 Pages
-
Tiva 500Washer Disinfector
8 Pages
Archived catalogs
-
Pharmaceutical Autoclaves
16 Pages