Engineering Data Pack - HD Series
21Pages

{{requestButtons}}

Catalog excerpts

Engineering Data Pack - HD Series - 1

Engineering Data Pack HD Industrial Duty Pumps Excellence at work. Excellence in life.

Open the catalog to page 1
Engineering Data Pack - HD Series - 2

HD Maximum Case, Differential, Discharge, and Suction

Open the catalog to page 2
Engineering Data Pack - HD Series - 3

70A Pump Mounting Dimensions 7 2416 70A Pump Mounting Dimensions with Flanged Ports 3 134 3" NPT FLANGED SUCTION PORT 2" NPT FLANGED DISCHARGE PORT Flanged Port Dimensions Size "X" "Y" Iron Pump CS ANSI 150# R.F. 14 23/32" ± 1/2" 15 5/32" ± 1/2"

Open the catalog to page 3
Engineering Data Pack - HD Series - 4

120A Pump Mounting Dimensions 7 2416 120A Pump Mounting Dimensions with Flanged Ports 3 134 4" NPT FLANGED SUCTION PORT 5 8 (4) 13 TYP. 32 MTG. HOLES 3" NPT FLANGED DISCHARGE PORT Flanged Port Dimensions Size "X" "Y" Iron Pump CS ANSI 150# R.F. 13 17/32" ± 1/2" 15 3/8" ± 1/2"

Open the catalog to page 4
Engineering Data Pack - HD Series - 5

330 Pump Mounting Dimensions 2915 32 330 Pump Mounting Dimensions with Flanged Ports 2915 32 "X" 5" NPT FLANGED SUCTION PORT Flanged Port Dimensions Size "X" "Y" Iron Pump CS ANSI 150# R.F. 18 3/32" ± 1/2" 19" ± 1/2"

Open the catalog to page 5
Engineering Data Pack - HD Series - 6

600 Pump Mounting Dimensions 9 3616 600 Pump Mounting Dimensions with Flanged Ports 9 3616 Flanged Port Dimensions Size "X" Iron Pump CS ANSI 150# R.F. 11 5/32" ± 1/2" Stainless Steel Pump SS ANSI 150# F.F. SS ANSI 150# R.F. SS ANSI 300# R.F. 11 5/32" ± 1/2" 11 5/32" ± 1/2" 11 21/32" ± 1/2"

Open the catalog to page 6
Engineering Data Pack - HD Series - 7

Pos. 1 & 2 - Pump 05 = Industrial Duty (ID) Pos. 3 & 4 - Model 16 = Model 70A 31 = Model 120A 75 = Model 330 91 = Model 600 Pos. 5 & 6 - Material of Construction 04 = 316 Stainless Steel 09 = Ductile Iron Pos. 7 - Port 0 = Internal NPT (Std. on ID Models) 3 = Flanged Port Option Pos. 8 - Relief Valve 0 = No Relief Valve Pos. 9 & 10 - Options 01 = Hot Clearance 02 = Special Shaft Material 05 = Special Packing 06 = Special Packing Configuration 08 = Mechanical Seals 09 = Special Bushings 10 = Special Clearances 13 = Steam Jacket/Tracing 19 = Special Ports (ie. Flanged) 21 = Tutriding 26 =...

Open the catalog to page 7
Engineering Data Pack - HD Series - 9

Note: Tuthill can supply a variety of seals with different material combinations to suit specific application requirements. The above list displays the most common/standard seal combinations used. Viton® - Registered trademark of E.I. DuPont De Nemours & Company Gylon® - Registered trademark of Garlock, Inc.

Open the catalog to page 9
Engineering Data Pack - HD Series - 10

D = STUFFING BOX BORE J = LENGTH TO OBSTRUCTION R = STUFFING BOX DEPTH HOUSING E = STUFFING BOX BORE DEPTH FACE PLATE L = STUD LENGTH FACEPLATE S = SHAFT DIAMETER HOUSING F = FACEPLATE SHAFT DIAMETER M = LENGTH TO OBSTRUCTION V = STUD LENGTH H = LENGTH TO OBSTRUCTION FACEPLATE SIDE K = STUD INFORMATION W = LENGTH TO NEAREST OBSTRUCTION

Open the catalog to page 10
Engineering Data Pack - HD Series - 11

NPSHr (Feet of Water) Pump Speed (RPM) Version 1.7

Open the catalog to page 11
Engineering Data Pack - HD Series - 12

Priming Ability of HD Series Pumps Performance curves indicating priming ability of pumps based on test data obtained on new pumps. Priming ability of older pumps, because of larger clearances, will not be as good. DUCTILE IRON (STD. CLEARANCE) DUCTILE IRON (HOT CLEARANCE) STAINLESS STEEL (STD. CLEARANCE) STAINLESS STEEL (HOT CLEARANCE)

Open the catalog to page 12
Engineering Data Pack - HD Series - 13

Horsepower Multiplying Factor Vs. Viscosity BHP Multiplying Facto

Open the catalog to page 13
Engineering Data Pack - HD Series - 14

SINGLE LOBE IMPELLERS NEEDED

Open the catalog to page 14
Engineering Data Pack - HD Series - 15

The Tuthill process pump is ideally suited for slurries, since it is capable of handling a wide range of apparent viscosities and solid particle sizes. When sizing a process pump, you must determine the viscosity of the carrier fluid, particle size, and particle hardness. The thicker the carrier fluid, the less recirculation of product through the fluid chamber clearances (slip), thus there is less erosive wear from any abrasive particle. If the carrier fluid is water thin, the abrasive particles are allowed to re-circulate in the clearances, resulting in a short wear life. Particle size...

Open the catalog to page 15
Engineering Data Pack - HD Series - 16

Available Options: • Packing: Pure PTFE, Graphite, other special materials available on request • Shaft: Steel, Armco 17-4PH, 316 S.S. (all have ceramic coating option) • Style #1 packing is the standard for all HD models

Open the catalog to page 16
Engineering Data Pack - HD Series - 17

Style #2 (Lantern Ring) Recommended Usage: • Grease lubrication improves sealing and packing life • Vent to suction side of pump to reduce pressure on outboard packing • Flush with clean fluid at 15-20 PSI above pump discharge pressure • Some product dilution will occur so compatible fluid must be used This design is the same as Style #1 except lantern ring and "in" and "out" flush connections are provided in the approximate location shown. A minimum of two rings of packing will be installed inboard to throttle flow. Standard lantern ring material is glass filled PTFE. Rings may be made in...

Open the catalog to page 17
Engineering Data Pack - HD Series - 18

Construction The jacket has a fabricated carbon steel plate type insert with an aluminum cast outer shell. Jacket is made in two-piece construction for field installation and/or pump maintenance access. Each half has V2" NPT (internal) in and out ports. Rating: • Steam or heat transfer fluids • 150-PSI maximum pressure • 500°F maximum temperature

Open the catalog to page 18
Engineering Data Pack - HD Series - 19

Factory or field installed. Standard grade Thermon or other heat transfer cement is applied between pump and jacket for best efficiency. Applications where pumped fluid must be maintained at temperature in order to remain in liquid form so the pump can pump the fluid are ideal for a steam jacket. General Ph Chart

Open the catalog to page 19
Engineering Data Pack - HD Series - 20

* Max. Case Pressure for Standard Duty models with wing nuts is 150 PSI for Stainless Steel and 200 PSI for Ductile Iron. 500 PSI rating can be achieved by replacing wing nuts with standard hex head nuts torqued to industry standards. Flange Ratings (Cast Iron) Temperature (deg C) This chart shows the ratings for flanges only - the maximum pump operating conditions must also be checked. Consult the appropriate Tuthill catalog for maximum allowable operating pressures and temperatures, based on pump application conditions and pump features. These ratings are based on non-shock...

Open the catalog to page 20
Engineering Data Pack - HD Series - 21

Flange Ratings (Stainless Steel) Temperature (°C) -45 ThIs chart shows the ratings for flanges only - the maximum pump operating conditions must also be checked. Consult the appropriate Tuthill catalog for maximum allowable operating pressures and temperatures, based on pump application conditions and pump features. These ratings are based on non-shock pressures. ANSI data is from ASME/ANSI B16.5 - 1988 (matl group 2.2). Consult this spec for more information. WARNING Rapid temperature change can result in flange failure and leakage, which can cause property damage or serious injury. Do not...

Open the catalog to page 21