TVMS2 [60Hz]_IA137-C

TVMS2 [60Hz]_IA137-C
1 / 11 PagesView full catalog

TVMS2 [60Hz]_IA137-C

Product catalog summary

Overview

This document is a technical catalog from TSURUMI MANUFACTURING CO., LTD. detailing the TVMS2 series of pumps. It includes specifications, performance data, installation sketches, and size and weight tables for various pump models within the series.

Sections and Content

1. Pump Models and Variants

The TVMS2 series includes multiple pump models identified by numbers such as TVMS2-1, TVMS2-3, TVMS2-5, TVMS2-10, TVMS2-15, TVMS2-20, TVMS2-32, TVMS2-42, TVMS2-65, TVMS2-85, TVMS2-120, TVMS2-150, and TVMS2-200. Each model has subvariants indicated by additional numbers (e.g., TVMS2-1-20, TVMS2-3-50).

2. Performance Specifications

  • Performance curves are provided for each pump model, compliant with ISO 9906 standards, at 3500 rpm.
  • Flow rates are expressed in cubic meters per hour (m³/h), with detailed performance tables for each variant.
  • Minimum inlet pressure and maximum working pressure parameters are indicated but specific values are not detailed in the excerpt.
  • Maximum ambient temperature ratings are referenced but exact limits are not specified.

3. Installation Information

Installation sketches accompany each pump model, providing guidance on proper setup and integration.

4. Size and Weight Data

Tables listing size and weight for each pump variant are included to assist in planning and logistics.

Key Technical Highlights

  • All performance data adhere to ISO 9906 standards ensuring reliability and accuracy.
  • The pumps operate at a standard speed of 3500 rpm.
  • Multiple pump sizes and capacities are available to suit various industrial applications.
  • Comprehensive documentation supports selection, installation, and maintenance.

Limitations and Missing Details

The document excerpt does not provide explicit numeric values for pressures, temperatures, or detailed performance metrics. It primarily lists model identifiers and references to performance curves and tables.

Summary

This TSURUMI TVMS2 pump catalog serves as a comprehensive technical reference for selecting and installing pumps across a wide range of capacities and sizes. It emphasizes standardized performance testing, detailed installation guidance, and thorough size and weight specifications to support industrial users.

See more

Catalog excerpts

TVMS2 [60Hz]_IA137-C-1

VERTICAL MULTISTAGE IN-LINE PUMPS

 Open the catalog to page 1
TVMS2 [60Hz]_IA137-C-2

^Tsurumi Pump 1 .Applications TVMS2 vertical multistage in-line stainless teel centrifugal pumps are designed in new generation, high efficiency and perfect performance. It referred to the European standard with new industrial design. It is energy saving, low noise, environment friendly,compact design, beautiful shape, light, easy for service,high reliability, a. Pumped liquids Thin, non-explosive liquids, not containing solid particles. The liquid must not attack the pump materials chemically. When pumping liquids with a density or viscosity higher than that of water, motor with correspondingly...

 Open the catalog to page 2
TVMS2 [60Hz]_IA137-C-3

^Tsurumi Pump General arrangement drawing General arrangement drawing TVMS2-1, 3, 5 Please check with us for other materials. Please check with us for other materials. Please check with us for other materials. Please check with us for other materials. 03 | TSURUMI PUMP TSURUMIPUMP | 04

 Open the catalog to page 3
TVMS2 [60Hz]_IA137-C-4

^Tsurumi Pump Max. Working Pressure Max. Ambient temperature Technical Data Model When the pump operates under ambient temperature higher than 40°C or under altitude higher than 1000m, because of low air density and poor cooling effects, the motor output power P2 will be decreased to certain extent. If the pump is operated under the above-said conditions, it should be equipped with motor of higher power. Performance curve ISO9906 3500rpm Min. Inlet Pressure TVMS2-1 Installation sketch In case that the pressure in pump is lower than the steam pressure used to convey liquid, the cavitations will...

 Open the catalog to page 4
TVMS2 [60Hz]_IA137-C-5

^Tsurumi Pump Technical Data Technical Data TVMS23 Installation sketch TVMS2-5 Installation sketch Performance table Size and weightPerformance table Size and weight 07 TVMS2-Note 2:The overall dimensions of the single-phase motor and explosive-proof motor are a little different. Please contact us for details. TVMS2-Note 2:The overall dimensions of the single-phase motor and explosive-proof motor are a little different. Please contact us for details. TSURUMI PUMP

 Open the catalog to page 5
TVMS2 [60Hz]_IA137-C-6

^Tsurumi Pump Technical Data Technical Data Performance table Size and weight Performance table Size and weight TVMS2-Note 2:The overall dimensions of the single-phase motor and explosive-proof motor are a little different. Please contact us for details. The overall dimensions of the single-phase motor and explosive-proof motor are a little different. Please contact us for details.

 Open the catalog to page 6
TVMS2 [60Hz]_IA137-C-7

^Tsurumi Pump Technical Data Technical Data TVMS2-20 Installation sketch TVMS2-32 Installation sketch r Performance table Size and weightPerformance table Size and weight Model The overall dimensions of the single-phase motor and explosive-proof motor are a little different. Please contact us for details.

 Open the catalog to page 7
TVMS2 [60Hz]_IA137-C-8

^Tsurumi Pump Technical Data Technical Data The overall dimensions of the single-phase motor and explosive-proof motor are a little different. Please contact us for details.

 Open the catalog to page 8
TVMS2 [60Hz]_IA137-C-9

^Tsurumi Pump Technical Data Technical Data Performance curve ISO9906 3500rpm Performance curve ISO9906 3500rpm TVMS2-85 Installation sketch TVMS 2-120 Installation sketch r \ Performance table Size and weight Performance table Size and weight Model The overall dimensions of the single-phase motor and explosive-proof motor are a little different. Please contact us for details.

 Open the catalog to page 9
TVMS2 [60Hz]_IA137-C-10

^Tsurumi Pump Technical Data Technical Data TVMS 2-150 Installation sketch TVMS2-200 Installation sketch r \ Performance table Size and weightPerformance table Size and weight Model The overall dimensions of the single-phase motor and explosive-proof motor are a little different. Please contact us for details. The overall dimensions of the single-phase motor and explosive-proof motor are a little different. Please contact us for details.

 Open the catalog to page 10
TVMS2 [60Hz]_IA137-C-11

& Tsurumi Pumpwww.tsurumi-global.com We reserve the right to change the specifications and designs without prior notice. The 00 series and model 00 are indicated with our series/model codes in this catalog. Your Dealer TSURUMI MANUFACTURING CO., LTD.© 2023 TSURUMI MANUFACTURING CO., LTD. Printed in Japan IA137-C NZ-X-A-A

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.